A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a va...A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.展开更多
In low-temperature processes, there are interactions between heat exchanger network(HEN) and refrigeration system. The modification on HEN of the chilling train for increasing energy recovery does not always coordinat...In low-temperature processes, there are interactions between heat exchanger network(HEN) and refrigeration system. The modification on HEN of the chilling train for increasing energy recovery does not always coordinate with the minimum shaft work consumption of the corresponding refrigeration system. In this paper, a systematic approach for optimizing low-temperature system is presented through mathematical method and exergy analysis. The possibility of "pockets", which appears as right nose section in the grand composite curve(EGCC) of the process, is first optimized. The EGCC with the pockets cutting down is designed as a separate part. A case study is used to illustrate the application of the approach for a HEN of a chilling train with propylene and ethylene refrigerant system in an ethylene production process.展开更多
Most commercial and industrial facilities require very low temperatures for refrigeration and high temperatures for space heating and hot water purposes. Single stage heat pumps have not been able to meet these temper...Most commercial and industrial facilities require very low temperatures for refrigeration and high temperatures for space heating and hot water purposes. Single stage heat pumps have not been able to meet these temperature demands and have been characterized by low capacities and coefficient of performance(COP). Cascade heat pump has been developed to overcome the weaknesses of single stage heat pumps. This study reviews recent works done by researchers on cascade heat pumps for refrigeration, heating and hot water generation. Selection of suitable refrigerants to meet the pressure and temperature demands of each stage of the cascade heat pump has been discussed. Optimization of design parameters such as intermediate temperature(low stage condensing and high stage evaporating temperatures), and temperature difference in the cascade heat exchanger for optimum performance of the cascade heat pump has been reviewed. It was found that optimising each design parameter of the cascade heat pump is necessary for maximum system performance and this may improve the exergetic efficiency, especially of cascade refrigeration systems, by about 30.88%. Cascade heat pumps have wider range of application especially for artificial snow production, in the supermarkets,for natural gas liquefaction, in drying clothes and food and as heat recovery system. The performance of cascade heat pumps can be improved by 19% when coupled with other renewable energy sources for various real time applications. Also, there is the need for much research on refrigerant charge amount of cascade heat pumps, refrigerant-refrigerant heat exchangers to be used as cascade heat exchanger, cascade heat pumps for simultaneous cooling, heating and hot water generation and on the use of variable speed compressors and their control strategies in matching system capacity especially at part load conditions.展开更多
文摘A water loop variable refrigerant flow(WLVRF)air-conditioning system is designed to be applied in large-scale buildings in northern China.The system is energy saving and it is an integrated system consisting of a variable refrigerant flow(VRF)air-conditioning unit,a water loop and an air source heat pump.The water loop transports energy among different regions in the buildings instead of refrigerant pipes,decreasing the scale of the VRF air-conditioning unit and improving the performance.Previous models for refrigerants and building loads are cited in this investigation.Mathematical models of major equipment and other elements of the system are established using the lumped parameter method based on the DATAFIT software and the MATLAB software.The performance of the WLVRF system is simulated.The initial investments and the running costs are calculated based on the results of market research.Finally,a contrast is carried out between the WLVRF system and the traditional VRF system.The results show that the WLVRF system has a better working condition and lower running costs than the traditional VRF system.
基金Supported by the National Basic Research Program of China(2010CB720500)the National Natural Science Foundation(21176178)
文摘In low-temperature processes, there are interactions between heat exchanger network(HEN) and refrigeration system. The modification on HEN of the chilling train for increasing energy recovery does not always coordinate with the minimum shaft work consumption of the corresponding refrigeration system. In this paper, a systematic approach for optimizing low-temperature system is presented through mathematical method and exergy analysis. The possibility of "pockets", which appears as right nose section in the grand composite curve(EGCC) of the process, is first optimized. The EGCC with the pockets cutting down is designed as a separate part. A case study is used to illustrate the application of the approach for a HEN of a chilling train with propylene and ethylene refrigerant system in an ethylene production process.
基金supported by the New&Renewable Energy Core Technology Program of the Korea Institute of Energy Technology Evaluation and Planning(KETEP)grant funded by the Korea government Ministry of Trade,Industry&Energy(Grant No.20143030111000)
文摘Most commercial and industrial facilities require very low temperatures for refrigeration and high temperatures for space heating and hot water purposes. Single stage heat pumps have not been able to meet these temperature demands and have been characterized by low capacities and coefficient of performance(COP). Cascade heat pump has been developed to overcome the weaknesses of single stage heat pumps. This study reviews recent works done by researchers on cascade heat pumps for refrigeration, heating and hot water generation. Selection of suitable refrigerants to meet the pressure and temperature demands of each stage of the cascade heat pump has been discussed. Optimization of design parameters such as intermediate temperature(low stage condensing and high stage evaporating temperatures), and temperature difference in the cascade heat exchanger for optimum performance of the cascade heat pump has been reviewed. It was found that optimising each design parameter of the cascade heat pump is necessary for maximum system performance and this may improve the exergetic efficiency, especially of cascade refrigeration systems, by about 30.88%. Cascade heat pumps have wider range of application especially for artificial snow production, in the supermarkets,for natural gas liquefaction, in drying clothes and food and as heat recovery system. The performance of cascade heat pumps can be improved by 19% when coupled with other renewable energy sources for various real time applications. Also, there is the need for much research on refrigerant charge amount of cascade heat pumps, refrigerant-refrigerant heat exchangers to be used as cascade heat exchanger, cascade heat pumps for simultaneous cooling, heating and hot water generation and on the use of variable speed compressors and their control strategies in matching system capacity especially at part load conditions.