A new hydraulic system of a novel automatic transmission (AT) was designed. The dimension and structure of valves and cylinders were designed by theoretical calculation. The dynamic simulation model of hydraulic syste...A new hydraulic system of a novel automatic transmission (AT) was designed. The dimension and structure of valves and cylinders were designed by theoretical calculation. The dynamic simulation model of hydraulic system of AT was established by ITI-SimulationX. Simulation results and theoretical design results were compared to confirm the simulation model. Based on the confirmed simulation model, the simulation results of pressure and flow of the hydraulic system were analyzed. The dynamic simulation method is very helpful for designing and analyzing the performance of hydraulic system and further optimization design. The theoretical design method and dynamic simulation model are feasible for the real industrial applications. The research results can be used in hydraulic system design and optimization.展开更多
The methodology for modeling no-frost refrigerator is described based on the component models developed in PartⅠ,and then,system simulation is applied to a BCD-235W refrigerator-freezer(RF).Experiments are carried ou...The methodology for modeling no-frost refrigerator is described based on the component models developed in PartⅠ,and then,system simulation is applied to a BCD-235W refrigerator-freezer(RF).Experiments are carried out to study'pull-down'and steady-state performance of the RF,and to determine how the experiment and simulation temperature stack up against each other.Good match is found between simulated and measured results for the'pull-down'period.For the steady-state period,the simulation results are also found to agree well with experiment ones except for the temperature profiles of the refrigerator compartment(RC) and freezer compartment(FC).The average temperature and the energy consumption errors between measurement and simulation are less than 10%.Although the model can not reflect the non-uniform air temperature fields in the RC and FC,the variation range and periodicities of the temperature correlate well between the simulation and experiment.We conclude that such a model is valid for investigating the performance of no-frost refrigerator.展开更多
基金Project(911901204) supported by Youth Innovation Foundation of Beijing University of Aeronautics and Astronautics
文摘A new hydraulic system of a novel automatic transmission (AT) was designed. The dimension and structure of valves and cylinders were designed by theoretical calculation. The dynamic simulation model of hydraulic system of AT was established by ITI-SimulationX. Simulation results and theoretical design results were compared to confirm the simulation model. Based on the confirmed simulation model, the simulation results of pressure and flow of the hydraulic system were analyzed. The dynamic simulation method is very helpful for designing and analyzing the performance of hydraulic system and further optimization design. The theoretical design method and dynamic simulation model are feasible for the real industrial applications. The research results can be used in hydraulic system design and optimization.
文摘The methodology for modeling no-frost refrigerator is described based on the component models developed in PartⅠ,and then,system simulation is applied to a BCD-235W refrigerator-freezer(RF).Experiments are carried out to study'pull-down'and steady-state performance of the RF,and to determine how the experiment and simulation temperature stack up against each other.Good match is found between simulated and measured results for the'pull-down'period.For the steady-state period,the simulation results are also found to agree well with experiment ones except for the temperature profiles of the refrigerator compartment(RC) and freezer compartment(FC).The average temperature and the energy consumption errors between measurement and simulation are less than 10%.Although the model can not reflect the non-uniform air temperature fields in the RC and FC,the variation range and periodicities of the temperature correlate well between the simulation and experiment.We conclude that such a model is valid for investigating the performance of no-frost refrigerator.