For the shock wave overpressure signal measurement of explosion field, the type and equivalent of the ammunition as well as the distance from test nodes to ground zero have a great influence on the characteristics of ...For the shock wave overpressure signal measurement of explosion field, the type and equivalent of the ammunition as well as the distance from test nodes to ground zero have a great influence on the characteristics of shock wave signal. To ensure that shock wave signal with different characteristic parameters can be collected completely in the test of shooting range, a tran- sient pressure signal storage system with configurable parameters is presented. In order to meet the requirements of different test nodes, the system can set parameters of all test nodes by wireless communication in explosion field. The feasibility and re- liability of the system are fully verified through transient pressure measurement in explosion field.展开更多
Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configurat...Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configuration type and borehole size of geothermal heat exchanger. These eventually determined the operation and cost efficiency of the geothermal heat exchanger system. The main purpose of this work was to assess the thermal performance of geother^nal heat exchanger with variation of borehole sizes and numbers of U-tubes inside a borehole. For this, a thermal response test rig was established with line-source theory. The thermal response test was performed with in-line variable input heat source. Effective thermal conductivity and thermal resistance were obtained from the measured data. From the measurement, the effective thermal conductivity is found to have similar values for two- pair type (4 U-tubes) and three-pair type (6 U-tubes) borehole heat exchanger systems indicating similar heat transfer ability. Meanwhile, the thermal resistance shows lower value for the three-pair type compared to the two-pair type. Measured data based resistance have lower value compared to computed result from design programs. Overall comparison finds better thermal performance for the three-pair type, however, fluctuating temperature variation indicates complex flow behavior inside the borehole and requires further study on flow characteristics.展开更多
State feedback and pole assignment of the second order coupled singular distributed parameter systems are discussed via functional analysis and operator theory in Hilbert space, in which infinite many poles are change...State feedback and pole assignment of the second order coupled singular distributed parameter systems are discussed via functional analysis and operator theory in Hilbert space, in which infinite many poles are changed. The solutions of the problem and the constructive expression of the solutions are given by the generalized inverse of bounded linear operator. This research is theoretically important for studying the pole assignment and stabilization of the singular distributed parameter systems.展开更多
基金The 11th Postgraduate Technological Innovation Project of North University of China(No.20141150)
文摘For the shock wave overpressure signal measurement of explosion field, the type and equivalent of the ammunition as well as the distance from test nodes to ground zero have a great influence on the characteristics of shock wave signal. To ensure that shock wave signal with different characteristic parameters can be collected completely in the test of shooting range, a tran- sient pressure signal storage system with configurable parameters is presented. In order to meet the requirements of different test nodes, the system can set parameters of all test nodes by wireless communication in explosion field. The feasibility and re- liability of the system are fully verified through transient pressure measurement in explosion field.
基金Project financially supported by the Second Stage of Brain Korea 21 Projects and Changwon National University,Korea
文摘Thermal performance was the most important factor in the development of borehole heat exchanger utilizing geothermal energy. The thermal performance was affected by many different design parameters, such as configuration type and borehole size of geothermal heat exchanger. These eventually determined the operation and cost efficiency of the geothermal heat exchanger system. The main purpose of this work was to assess the thermal performance of geother^nal heat exchanger with variation of borehole sizes and numbers of U-tubes inside a borehole. For this, a thermal response test rig was established with line-source theory. The thermal response test was performed with in-line variable input heat source. Effective thermal conductivity and thermal resistance were obtained from the measured data. From the measurement, the effective thermal conductivity is found to have similar values for two- pair type (4 U-tubes) and three-pair type (6 U-tubes) borehole heat exchanger systems indicating similar heat transfer ability. Meanwhile, the thermal resistance shows lower value for the three-pair type compared to the two-pair type. Measured data based resistance have lower value compared to computed result from design programs. Overall comparison finds better thermal performance for the three-pair type, however, fluctuating temperature variation indicates complex flow behavior inside the borehole and requires further study on flow characteristics.
基金supported by the National Nature Science Foundation of China under Grant No.60674018
文摘State feedback and pole assignment of the second order coupled singular distributed parameter systems are discussed via functional analysis and operator theory in Hilbert space, in which infinite many poles are changed. The solutions of the problem and the constructive expression of the solutions are given by the generalized inverse of bounded linear operator. This research is theoretically important for studying the pole assignment and stabilization of the singular distributed parameter systems.