For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection int...For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments.展开更多
Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The prin...Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The principle of the proposed technique to reduce the fading noise is introduced based on the analysis of Rayleigh Brillouin optical time domain analysis system. The experimental results show that the signal-to-noise ratio(SNR) at the end of optical fiber with length of 50 m after 17 times wavelength scanning is 5.21 d B higher than that with single wavelength, the Brillouin frequency shift(BFS) on the heated fiber with length of 70 m inserted at the center of sensing fiber can be accurately measured as 0.19 MHz, which is equivalent to a measurement accuracy of 0.19 °C. It indicates that the proposed technique can realize high-accuracy temperature measurement and has huge potential in the field of long-distance and high-accuracy sensing.展开更多
文摘For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments.
基金supported by the National Natural Science Foundation of China(No.61377088)the Natural Science Foundation of Hebei Province of China(Nos.E2015502053 and F2015502059)the Fundamental Research Funds for the Central Universities(No.2016XS104)
文摘Aiming at the problem of large fading noise in Rayleigh Brillouin optical time domain analysis system, a wavelength scanning technique is proposed to enhance the performance of the temperature sensing system. The principle of the proposed technique to reduce the fading noise is introduced based on the analysis of Rayleigh Brillouin optical time domain analysis system. The experimental results show that the signal-to-noise ratio(SNR) at the end of optical fiber with length of 50 m after 17 times wavelength scanning is 5.21 d B higher than that with single wavelength, the Brillouin frequency shift(BFS) on the heated fiber with length of 70 m inserted at the center of sensing fiber can be accurately measured as 0.19 MHz, which is equivalent to a measurement accuracy of 0.19 °C. It indicates that the proposed technique can realize high-accuracy temperature measurement and has huge potential in the field of long-distance and high-accuracy sensing.