The advancement of grey system theory provides an effective analytic tool for power system load fore-cast. All kinds of presently available grey forecast models can be well used to deal with the short-term load fore-c...The advancement of grey system theory provides an effective analytic tool for power system load fore-cast. All kinds of presently available grey forecast models can be well used to deal with the short-term load fore-cast. However, they make big errors for medium or long-term load forecasts, and the load that does not satisfythe approximate exponential increasing law in particular. A novel grey forecast model that is capable of distin-guishing the increasing law of load is adopted to forecast electric power consumption (EPC) of Shanghai. Theresults show that this model can be used to greatly improve the forecast precision of EPC for a secondary industryor the whole society.展开更多
To decrease the cost of electricity generation of a residential molten carbonate fuel cell (MCFC) power system, multi-crossover genetic algorithm (MCGA), which is based on "multi-crossover" and "usefulness-base...To decrease the cost of electricity generation of a residential molten carbonate fuel cell (MCFC) power system, multi-crossover genetic algorithm (MCGA), which is based on "multi-crossover" and "usefulness-based selection rule", is presented to minimize the daily fuel consumption of an experimental 10kW MCFC power system for residential application. Under the operating conditions obtained by MCGA, the operation constraints are satisfied and fuel consumption is minimized. Simulation and experimental results indicate that MCGA is efficient for the operation optimization of MCFC power systems.展开更多
A new clutch configuration with dual diaphragm spring is proposed. It is proper designed for electric and hybrid powertrain system. With this design, the clutch engagement is controlled by current in electrornagnet co...A new clutch configuration with dual diaphragm spring is proposed. It is proper designed for electric and hybrid powertrain system. With this design, the clutch engagement is controlled by current in electrornagnet coil. For special characteristic of dual diaphragm spring, the clutch does not consume energy in steady state after engaging or disengaging. To validate the feasibility of this design, author builds the mathematical model and imports it into MATLAB Simulink. The simulation shows the behavior of clutch in different control strategies.展开更多
The main objective of this paper is to show an overview analysis of market power issues.Market power reflects the scarcity of power supply.It is the ability of a particular seller or group of sellers to maintain price...The main objective of this paper is to show an overview analysis of market power issues.Market power reflects the scarcity of power supply.It is the ability of a particular seller or group of sellers to maintain prices profitably above competitive levels for a significant period of time.Because the electric power system has its own characteristics that are different to other economic systems,both physical factors and economic factors of power system are key elements on this definition.We study some cases here,including different line limit levels,load levels and bid strategy through a market model based on OPF (optimal power flow) with a decommitment algorithm.展开更多
In distribution systems,network reconfiguration and capacitor placement are commonly used to diminish power losses and keep voltage profiles within acceptable limits.Moreover,the problem of DG allocation and sizing is...In distribution systems,network reconfiguration and capacitor placement are commonly used to diminish power losses and keep voltage profiles within acceptable limits.Moreover,the problem of DG allocation and sizing is great important.In this work,a combination of a fuzzy multi-objective approach and bacterial foraging optimization(BFO) as a meta-heuristic algorithm is used to solve the simultaneous reconfiguration and optimal sizing of DGs and shunt capacitors in a distribution system.Each objective is transferred into fuzzy domain using its membership function.Then,the overall fuzzy satisfaction function is formed and considered a fitness function inasmuch as the value of this function has to be maximized to gain the optimal solution.The numerical results show that the presented algorithm improves the performance much more than other meta-heuristic algorithms.Simulation results found that simultaneous reconfiguration with DG and shunt capacitors allocation(case 5) has 77.41%,42.15%,and 56.14%improvements in power loss reduction,load balancing,and voltage profile indices,respectively in 33-bus test system.This result found 87.27%,35.82%,and 54.34%improvements of mentioned indices respectively for 69-bus system.展开更多
This paper presents the investigation of energy and cost saving of microgeneration systems which consist of conventional, load sharing, renewable energy and hybrid-renewable energy systems application featuring single...This paper presents the investigation of energy and cost saving of microgeneration systems which consist of conventional, load sharing, renewable energy and hybrid-renewable energy systems application featuring single detached house and office buildings by implementing spreadsheet modeling. Microsoft excel is employed as the spreadsheet application in this study. The system performance of each case is calculated under typical weather of ottawa, canada. These cases are calculated and analyzed in terms of thermal/cooling load (building demand) and natural gas/electricity consumption (energy supply) as well as the financial part by involving several parameters which are initial cost, annual energy consumption cost, annual operational and maintenance cost, inflation rate, and return on investment. Moreover, a house and an office have the same geometry of 200 mE. Total of seven cases modeling are developed; Case-1- a house with boiler and chiller, Case-2- an office with boiler and chiller, Case-3-a simple sum of Case l and Case 2, Case-4- a load-sharing model, Case-5- a load-sharing with GSHP (ground source heat pump), Case-6- a load-sharing with ground source heat pump-fuel cell hybrid system (FC-GSHP)and Case-7- a load-sharing with GSHP--photovoltaic hybrid system (PVT-GSHP). As the results, it will be observed the efficiency of the load-sharing, renewable energy, hybrid-renewable energy implementation comparing to the conventional system.展开更多
This paper presents some solutions of modem renewable energy system applied actually in dissipation energy source: wind turbine, solar panel battery charge, SSS (support set system), and standby diesel generator co...This paper presents some solutions of modem renewable energy system applied actually in dissipation energy source: wind turbine, solar panel battery charge, SSS (support set system), and standby diesel generator cooperated in series, parallel and hybrid system with main energy system. Its solution enable obtain independent individual energy source in different work exploitations. One of problems concerned with alternative energy source is changes of output voltages and output power dependence of climatic conditions. Possible solution is application of decoupled adjustable speed generation system in renewable energy generation. The decoupled generation system consists of: alternative energy source, internal combustion engine drives permanent magnet generator and DC/AC, or AC/AC converter. Performance of single decoupled generation set is discussed supported by results of laboratory tests. To provide high quality voltage is applied an additional energy storage, made from super capacitor and bidirectional DC/DC convert. Such system performs very stiff voltage in any load condition. Integration of solar battery panels or renewable wind energy system is provided via DC link of the variable speed decoupled autonomous generation system. Results of computer simulation and laboratory experiments are presented in the paper.展开更多
An upsurge of interest in relay-augmented infrastructure-based networks has appeared in recent years.Radio resource management in such relay systems has great influence on the system performance.How to utilize the lim...An upsurge of interest in relay-augmented infrastructure-based networks has appeared in recent years.Radio resource management in such relay systems has great influence on the system performance.How to utilize the limited frequency resources efficiently in the system is a hot research topic.In this paper,performance of frequency reuse schemes has been studied in fixed relay systems.A novel scheme is achieved by modifying an existing one.Theoretical model is proposed for the performance analysis of two schemes.Both the theoretical analysis and simulation results show that the modified scheme outperforms the existing one not only in power consumption of mobile stations but also in cell carrier-to-interference ratio coverage.展开更多
文摘The advancement of grey system theory provides an effective analytic tool for power system load fore-cast. All kinds of presently available grey forecast models can be well used to deal with the short-term load fore-cast. However, they make big errors for medium or long-term load forecasts, and the load that does not satisfythe approximate exponential increasing law in particular. A novel grey forecast model that is capable of distin-guishing the increasing law of load is adopted to forecast electric power consumption (EPC) of Shanghai. Theresults show that this model can be used to greatly improve the forecast precision of EPC for a secondary industryor the whole society.
文摘To decrease the cost of electricity generation of a residential molten carbonate fuel cell (MCFC) power system, multi-crossover genetic algorithm (MCGA), which is based on "multi-crossover" and "usefulness-based selection rule", is presented to minimize the daily fuel consumption of an experimental 10kW MCFC power system for residential application. Under the operating conditions obtained by MCGA, the operation constraints are satisfied and fuel consumption is minimized. Simulation and experimental results indicate that MCGA is efficient for the operation optimization of MCFC power systems.
文摘A new clutch configuration with dual diaphragm spring is proposed. It is proper designed for electric and hybrid powertrain system. With this design, the clutch engagement is controlled by current in electrornagnet coil. For special characteristic of dual diaphragm spring, the clutch does not consume energy in steady state after engaging or disengaging. To validate the feasibility of this design, author builds the mathematical model and imports it into MATLAB Simulink. The simulation shows the behavior of clutch in different control strategies.
基金This paper supported by National Natural Science Foundation of China (50079006).
文摘The main objective of this paper is to show an overview analysis of market power issues.Market power reflects the scarcity of power supply.It is the ability of a particular seller or group of sellers to maintain prices profitably above competitive levels for a significant period of time.Because the electric power system has its own characteristics that are different to other economic systems,both physical factors and economic factors of power system are key elements on this definition.We study some cases here,including different line limit levels,load levels and bid strategy through a market model based on OPF (optimal power flow) with a decommitment algorithm.
文摘In distribution systems,network reconfiguration and capacitor placement are commonly used to diminish power losses and keep voltage profiles within acceptable limits.Moreover,the problem of DG allocation and sizing is great important.In this work,a combination of a fuzzy multi-objective approach and bacterial foraging optimization(BFO) as a meta-heuristic algorithm is used to solve the simultaneous reconfiguration and optimal sizing of DGs and shunt capacitors in a distribution system.Each objective is transferred into fuzzy domain using its membership function.Then,the overall fuzzy satisfaction function is formed and considered a fitness function inasmuch as the value of this function has to be maximized to gain the optimal solution.The numerical results show that the presented algorithm improves the performance much more than other meta-heuristic algorithms.Simulation results found that simultaneous reconfiguration with DG and shunt capacitors allocation(case 5) has 77.41%,42.15%,and 56.14%improvements in power loss reduction,load balancing,and voltage profile indices,respectively in 33-bus test system.This result found 87.27%,35.82%,and 54.34%improvements of mentioned indices respectively for 69-bus system.
文摘This paper presents the investigation of energy and cost saving of microgeneration systems which consist of conventional, load sharing, renewable energy and hybrid-renewable energy systems application featuring single detached house and office buildings by implementing spreadsheet modeling. Microsoft excel is employed as the spreadsheet application in this study. The system performance of each case is calculated under typical weather of ottawa, canada. These cases are calculated and analyzed in terms of thermal/cooling load (building demand) and natural gas/electricity consumption (energy supply) as well as the financial part by involving several parameters which are initial cost, annual energy consumption cost, annual operational and maintenance cost, inflation rate, and return on investment. Moreover, a house and an office have the same geometry of 200 mE. Total of seven cases modeling are developed; Case-1- a house with boiler and chiller, Case-2- an office with boiler and chiller, Case-3-a simple sum of Case l and Case 2, Case-4- a load-sharing model, Case-5- a load-sharing with GSHP (ground source heat pump), Case-6- a load-sharing with ground source heat pump-fuel cell hybrid system (FC-GSHP)and Case-7- a load-sharing with GSHP--photovoltaic hybrid system (PVT-GSHP). As the results, it will be observed the efficiency of the load-sharing, renewable energy, hybrid-renewable energy implementation comparing to the conventional system.
文摘This paper presents some solutions of modem renewable energy system applied actually in dissipation energy source: wind turbine, solar panel battery charge, SSS (support set system), and standby diesel generator cooperated in series, parallel and hybrid system with main energy system. Its solution enable obtain independent individual energy source in different work exploitations. One of problems concerned with alternative energy source is changes of output voltages and output power dependence of climatic conditions. Possible solution is application of decoupled adjustable speed generation system in renewable energy generation. The decoupled generation system consists of: alternative energy source, internal combustion engine drives permanent magnet generator and DC/AC, or AC/AC converter. Performance of single decoupled generation set is discussed supported by results of laboratory tests. To provide high quality voltage is applied an additional energy storage, made from super capacitor and bidirectional DC/DC convert. Such system performs very stiff voltage in any load condition. Integration of solar battery panels or renewable wind energy system is provided via DC link of the variable speed decoupled autonomous generation system. Results of computer simulation and laboratory experiments are presented in the paper.
基金National Science Fund for Creative Research Groups(No.60521002)Chinese NationalKey Technology R&D Program(No.2005BA908B02)Science Foundation ofShanghai Municipal Commission of Scienceand Technology,Chinese(No.05dz05802)
文摘An upsurge of interest in relay-augmented infrastructure-based networks has appeared in recent years.Radio resource management in such relay systems has great influence on the system performance.How to utilize the limited frequency resources efficiently in the system is a hot research topic.In this paper,performance of frequency reuse schemes has been studied in fixed relay systems.A novel scheme is achieved by modifying an existing one.Theoretical model is proposed for the performance analysis of two schemes.Both the theoretical analysis and simulation results show that the modified scheme outperforms the existing one not only in power consumption of mobile stations but also in cell carrier-to-interference ratio coverage.