The energy saving issue of chilled water system in an intelligent building is analyzed from the systematic point of view, and an optimum scheduling scheme which can save energy of the system facilities and satisfy the...The energy saving issue of chilled water system in an intelligent building is analyzed from the systematic point of view, and an optimum scheduling scheme which can save energy of the system facilities and satisfy the constraints of the real time cold loads and system running is also proposed. It can make the minimum cost of the system by optimizing the number of running chillers, running parameters and the distribution of real time loads of running chillers. The improved genetic algorithm is used in the optimum scheduling scheme. The computation results show that the building energy consumption can be decreased by about 10%.展开更多
The reliable assessment of the annual energy demand has become necessary in view of building energy performance certification. Accurate models must be used to simulate the behaviour of HVAC (heating, ventilation and ...The reliable assessment of the annual energy demand has become necessary in view of building energy performance certification. Accurate models must be used to simulate the behaviour of HVAC (heating, ventilation and air conditioning) components in real operation, usually characterized by a wide variation of building loads. In this context, this paper deals with the development and validation of an algorithm aimed at the assessment of part load performance of various kinds of controls for vapour compresion based heat pumps and chillers, in particular referring to on-off, inverter-driven and multi-stage vapour compression. The reliability of this algorithm in the calculation of seasonal performances is checked against monitoring of heat pumps and chillers operating under real conditions.展开更多
The financial viability of a solar STES (seasonal thermal energy store) installed in a mixed commercial and residential multiunit development of low-energy buildings located in Lysekil, Sweden, a maritime Scandinavi...The financial viability of a solar STES (seasonal thermal energy store) installed in a mixed commercial and residential multiunit development of low-energy buildings located in Lysekil, Sweden, a maritime Scandinavian Climate has been investigated. Using recorded figures for the installation costs and performance, a financial life cycle analysis has been undertaken to determine the cost effectiveness of the system. The time value of money is considered and an LCC (life cycle cost) analysis undertaken to identify the cost-effectiveness of the solution. It shows that while a direct heating and hot water system incorporating STES can be economically viable in a Swedish maritime climate in the long term, assistance such as that provided by government incentives is required to assist with the high capital cost of the initial investment.展开更多
文摘The energy saving issue of chilled water system in an intelligent building is analyzed from the systematic point of view, and an optimum scheduling scheme which can save energy of the system facilities and satisfy the constraints of the real time cold loads and system running is also proposed. It can make the minimum cost of the system by optimizing the number of running chillers, running parameters and the distribution of real time loads of running chillers. The improved genetic algorithm is used in the optimum scheduling scheme. The computation results show that the building energy consumption can be decreased by about 10%.
文摘The reliable assessment of the annual energy demand has become necessary in view of building energy performance certification. Accurate models must be used to simulate the behaviour of HVAC (heating, ventilation and air conditioning) components in real operation, usually characterized by a wide variation of building loads. In this context, this paper deals with the development and validation of an algorithm aimed at the assessment of part load performance of various kinds of controls for vapour compresion based heat pumps and chillers, in particular referring to on-off, inverter-driven and multi-stage vapour compression. The reliability of this algorithm in the calculation of seasonal performances is checked against monitoring of heat pumps and chillers operating under real conditions.
文摘The financial viability of a solar STES (seasonal thermal energy store) installed in a mixed commercial and residential multiunit development of low-energy buildings located in Lysekil, Sweden, a maritime Scandinavian Climate has been investigated. Using recorded figures for the installation costs and performance, a financial life cycle analysis has been undertaken to determine the cost effectiveness of the system. The time value of money is considered and an LCC (life cycle cost) analysis undertaken to identify the cost-effectiveness of the solution. It shows that while a direct heating and hot water system incorporating STES can be economically viable in a Swedish maritime climate in the long term, assistance such as that provided by government incentives is required to assist with the high capital cost of the initial investment.