Research indicates that high levels of sedentary behavior(sitting or lying with low energy expenditure) are adversely associated with health. A key factor in improving our understanding of the impact of sedentary beha...Research indicates that high levels of sedentary behavior(sitting or lying with low energy expenditure) are adversely associated with health. A key factor in improving our understanding of the impact of sedentary behavior(and patterns of sedentary time accumulation) on health is the use of objective measurement tools that collect date and time-stamped activity information. One such tool is the activP AL monitor. This thigh-worn device uses accelerometer-derived information about thigh position to determine the start and end of each period spent sitting/lying, standing, and stepping, as well as stepping speed, step counts, and postural transitions. The activP AL is increasingly being used within field-based research for its ability to measure sitting/lying via posture. We summarise key issues to consider when using the activP AL in physical activity and sedentary behavior field-based research with adult populations. It is intended that the findings and discussion points be informative for researchers who are currently using activP AL monitors or are intending to use them. Pre-data collection decisions, monitor preparation and distribution, data collection considerations, and manual and automated data processing possibilities are presented using examples from current literature and experiences from 2 research groups from the UK and Australia.展开更多
High acceleration of radar targets is analyzed using Acceleration Ambiguity Function (AAF). The acceleration resolution based on AAF is defined. The AAF and acceleration resolution of rectangle pulse signal are deriva...High acceleration of radar targets is analyzed using Acceleration Ambiguity Function (AAF). The acceleration resolution based on AAF is defined. The AAF and acceleration resolution of rectangle pulse signal are derivated and the conclusion that its acceleration resolution is in inverse proportion with the square of its duration is drawn. In the end, these conclusions are applied to the parameter designing and performance evaluation for a certain type of pulse Doppler radar.展开更多
This study presents a new method of 4-pipelined high-performance split multiply-accumulator (MAC) architecture, which is capable of supporting multiple precisions developed for media processors. To speed up the design...This study presents a new method of 4-pipelined high-performance split multiply-accumulator (MAC) architecture, which is capable of supporting multiple precisions developed for media processors. To speed up the design further, a novel partial product compression circuit based on interleaved adders and a modified hybrid partial product reduction tree (PPRT) scheme are proposed. The MAC can perform 1-way 32-bit, 4-way 16-bit signed/unsigned multiply or multiply-accumulate operations and 2-way parallel multiply add (PMADD) operations at a high frequency of 1.25 GHz under worst-case conditions and 1.67 GHz under typical-case conditions, respectively. Compared with the MAC in 32-bit microprocessor without interlocked piped stages (MIPS), the proposed design shows a great advantage in speed. Moreover, an improvement of up to 32% in throughput is achieved. The MAC design has been fabricated with Taiwan Semiconductor Manufacturing Company (TSMC) 90-nm CMOS standard cell technology and has passed a functional test.展开更多
基金supported by the National Institute for Health Researsch (NIHR) DietLifestyle & Physical Activity Biomedical Research Unit based at University Hospitals of Leicester and Loughborough University+5 种基金the National Institute for Health Research Collaboration for Leadership in Applied Health Research and Care-East Midlands (NIHR CLAHRC- EM)the Leicester Clinical Trials Unitsupported by a National Health and Medical Research Council (NHMRC) Centre for Research Excellence Grant on Sitting Time and Chronic Disease Prevention-Measurement, Mechanisms and Interventions (APP1057608)supported by a Heart Foundation Postdoctoral (PH 12B 7054)NHMRC Career Development (#1086029) Fellowshipsupported by an Australian Research Council Future Fellowship (FTE 100100918)
文摘Research indicates that high levels of sedentary behavior(sitting or lying with low energy expenditure) are adversely associated with health. A key factor in improving our understanding of the impact of sedentary behavior(and patterns of sedentary time accumulation) on health is the use of objective measurement tools that collect date and time-stamped activity information. One such tool is the activP AL monitor. This thigh-worn device uses accelerometer-derived information about thigh position to determine the start and end of each period spent sitting/lying, standing, and stepping, as well as stepping speed, step counts, and postural transitions. The activP AL is increasingly being used within field-based research for its ability to measure sitting/lying via posture. We summarise key issues to consider when using the activP AL in physical activity and sedentary behavior field-based research with adult populations. It is intended that the findings and discussion points be informative for researchers who are currently using activP AL monitors or are intending to use them. Pre-data collection decisions, monitor preparation and distribution, data collection considerations, and manual and automated data processing possibilities are presented using examples from current literature and experiences from 2 research groups from the UK and Australia.
文摘High acceleration of radar targets is analyzed using Acceleration Ambiguity Function (AAF). The acceleration resolution based on AAF is defined. The AAF and acceleration resolution of rectangle pulse signal are derivated and the conclusion that its acceleration resolution is in inverse proportion with the square of its duration is drawn. In the end, these conclusions are applied to the parameter designing and performance evaluation for a certain type of pulse Doppler radar.
基金Project (No. 60873112) supported by the National Natural Science Foundation of China
文摘This study presents a new method of 4-pipelined high-performance split multiply-accumulator (MAC) architecture, which is capable of supporting multiple precisions developed for media processors. To speed up the design further, a novel partial product compression circuit based on interleaved adders and a modified hybrid partial product reduction tree (PPRT) scheme are proposed. The MAC can perform 1-way 32-bit, 4-way 16-bit signed/unsigned multiply or multiply-accumulate operations and 2-way parallel multiply add (PMADD) operations at a high frequency of 1.25 GHz under worst-case conditions and 1.67 GHz under typical-case conditions, respectively. Compared with the MAC in 32-bit microprocessor without interlocked piped stages (MIPS), the proposed design shows a great advantage in speed. Moreover, an improvement of up to 32% in throughput is achieved. The MAC design has been fabricated with Taiwan Semiconductor Manufacturing Company (TSMC) 90-nm CMOS standard cell technology and has passed a functional test.