The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a ...The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a camera is proposed by combining the imaging characteristics of a digital camera and the high-speed information processing capability of a computer.Two turbidity measurement devices based on visible and near-infrared(NIR)light cameras and a light source driving circuit with constant light intensity were designed.The RGB data in the turbidity images were acquired using a self-developed image processing software and converted to the CIE Lab color space.Based on the relationship between the luminance,chromatic aberration,and turbidity,the turbidity detection models for luminance and chromatic aberration of visible and NIR light devices exhibiting values from 0-1000 NTU,less than 100 NTU,and more than 100 NTU were established.By comparing and analyzing the proposed models,the two measurement models with the best all-around performance were selected and fused to generate new measurement models.The experimental results prove that the correlation between the three models and the commercial turbidity meter measurements exhibite a significance value higher than 0.999.The error of the fusion model is within 1.05%,with a mean square error of 1.14.The visible light device has less error at low turbidity measurements and is less influenced by the color of the image.The NIR light device is more stable and accurate at full range and high turbidity measurements and is therefore more suitable for such measurements.展开更多
The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acqu...The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acquisition.The equivalent blackbody temperature is obtained by the temperature calibration model that represents the quantitative relation,at a certain integration time,between the gray level value and the equivalent blackbody temperature.The temperature calibration model has been acquired by the curve fitting with the experimental data of blackbody temperature calibration using Origin 6.0.Then the target radiance can be determined by the radiant flux equivalence model built on condition that the target radiant flux received by the infrared detector is equivalent to that of the blackbody placed in front of the infrared detector at a close distance.This measuring method is based on the temperature calibration parameters and real image information,so it can avoid subjectivity of the traditional theory modeling methods.展开更多
基金National Natural Science Foundation of China(No.61671434)Key Projects of Provincial Natural Science Foundation of Anhui Universities(Nos.KJ2019A0952,KJ2017ZD32)。
文摘The conventional photoelectric detection system requires complex circuitry and spectroscopic systems as well as specialized personnel for its operation.To replace such a system,a method of measuring turbidity using a camera is proposed by combining the imaging characteristics of a digital camera and the high-speed information processing capability of a computer.Two turbidity measurement devices based on visible and near-infrared(NIR)light cameras and a light source driving circuit with constant light intensity were designed.The RGB data in the turbidity images were acquired using a self-developed image processing software and converted to the CIE Lab color space.Based on the relationship between the luminance,chromatic aberration,and turbidity,the turbidity detection models for luminance and chromatic aberration of visible and NIR light devices exhibiting values from 0-1000 NTU,less than 100 NTU,and more than 100 NTU were established.By comparing and analyzing the proposed models,the two measurement models with the best all-around performance were selected and fused to generate new measurement models.The experimental results prove that the correlation between the three models and the commercial turbidity meter measurements exhibite a significance value higher than 0.999.The error of the fusion model is within 1.05%,with a mean square error of 1.14.The visible light device has less error at low turbidity measurements and is less influenced by the color of the image.The NIR light device is more stable and accurate at full range and high turbidity measurements and is therefore more suitable for such measurements.
基金Supported by Innovation Project of Chinese Academy of Sciences(Grant No.C04708Z)
文摘The gray level values of target pixels of infrared images processed by the SUSAN noise filtering algorithm and the background filtering algorithm are calculated,assuming that the target distance is given in image acquisition.The equivalent blackbody temperature is obtained by the temperature calibration model that represents the quantitative relation,at a certain integration time,between the gray level value and the equivalent blackbody temperature.The temperature calibration model has been acquired by the curve fitting with the experimental data of blackbody temperature calibration using Origin 6.0.Then the target radiance can be determined by the radiant flux equivalence model built on condition that the target radiant flux received by the infrared detector is equivalent to that of the blackbody placed in front of the infrared detector at a close distance.This measuring method is based on the temperature calibration parameters and real image information,so it can avoid subjectivity of the traditional theory modeling methods.