We show that by scanning the frequency of a single mode infrared (IR) optical parametric oscillator (IR- OPO) laser to excite the molecular species of interest and fixing the frequency of a vacuum ultraviolet (VU...We show that by scanning the frequency of a single mode infrared (IR) optical parametric oscillator (IR- OPO) laser to excite the molecular species of interest and fixing the frequency of a vacuum ultraviolet (VUV) laser to photoionize the IR excited species, high-resolution IR spectra of polyatomic neutrals can be obtained with high sensitivity. The fact that this IR-VUV-photoion (IR-VUV-PI) method is based on VUV photoionization probe, and thus, allows the identification of the neutral IR absorber, makes it applicable for IR spectroscopy measurements of isotopemers, radicals, and clusters, which usually exist as impure samples. The highly resolved IR-VUV-PI measurements achieved using the single mode IR-OPO laser have made possible the selection of single rovibrational states of CH3X (X=Br and I), C2H4, and C3H4 for VUV-pulsed field ionization-photoelectron (VUV-PFI-PE) measurements, resulting in rovibrationally resolved photoelectron spectra for these polyatomic molecules. These experiments show that the signal- to-noise ratios of the IR-VUV-PI and IR-VUV-PFI-PE spectra obtained by employing the high-resolution IR-OPO laser are significantly higher than those observed in previous IR-VUV-PI and IR-VUV-PFI-PE studies using a low-resolution IR-OPO laser. Further improvement in sensitivity of IR-VUV-PI and IR- VUV-PFI-PE measurements by using the collinear arrangement of IR-VUV lasers and molecular beam is discussed.展开更多
For impulse radio ultra-wideband (IR-UWB) ranging systems,effects of the settings of transmitter-related parameters, which include the pulse shape, the bandwidth and the pulse repetition interval (PRI), on ranging acc...For impulse radio ultra-wideband (IR-UWB) ranging systems,effects of the settings of transmitter-related parameters, which include the pulse shape, the bandwidth and the pulse repetition interval (PRI), on ranging accuracy were studied through theoretical analysis and simulations. Both the match-filtering based coherent TOA estimation algorithm and the energy-detection based non-coherent algorithm were used during simulations. Results show that the pulse shape has the least effect on the ranging accuracy. Increasing the pulse bandwidth can improve the ranging performance, but the performance is hardly improved any more when the bandwidth is increased beyond a certain level. PRI should be set long enough to guarantee the accurate ranging, because when PRI is shorter than the maximum excess delay of the channel, the ranging accuracy will be deteriorated by inter-pulse interference.展开更多
文摘We show that by scanning the frequency of a single mode infrared (IR) optical parametric oscillator (IR- OPO) laser to excite the molecular species of interest and fixing the frequency of a vacuum ultraviolet (VUV) laser to photoionize the IR excited species, high-resolution IR spectra of polyatomic neutrals can be obtained with high sensitivity. The fact that this IR-VUV-photoion (IR-VUV-PI) method is based on VUV photoionization probe, and thus, allows the identification of the neutral IR absorber, makes it applicable for IR spectroscopy measurements of isotopemers, radicals, and clusters, which usually exist as impure samples. The highly resolved IR-VUV-PI measurements achieved using the single mode IR-OPO laser have made possible the selection of single rovibrational states of CH3X (X=Br and I), C2H4, and C3H4 for VUV-pulsed field ionization-photoelectron (VUV-PFI-PE) measurements, resulting in rovibrationally resolved photoelectron spectra for these polyatomic molecules. These experiments show that the signal- to-noise ratios of the IR-VUV-PI and IR-VUV-PFI-PE spectra obtained by employing the high-resolution IR-OPO laser are significantly higher than those observed in previous IR-VUV-PI and IR-VUV-PFI-PE studies using a low-resolution IR-OPO laser. Further improvement in sensitivity of IR-VUV-PI and IR- VUV-PFI-PE measurements by using the collinear arrangement of IR-VUV lasers and molecular beam is discussed.
基金Sponsored by the National Natural Science Foundation of China (Grant No.60432040)the Natural Science Foundation of Guangdong Privince(Grant No.9451805707003235)
文摘For impulse radio ultra-wideband (IR-UWB) ranging systems,effects of the settings of transmitter-related parameters, which include the pulse shape, the bandwidth and the pulse repetition interval (PRI), on ranging accuracy were studied through theoretical analysis and simulations. Both the match-filtering based coherent TOA estimation algorithm and the energy-detection based non-coherent algorithm were used during simulations. Results show that the pulse shape has the least effect on the ranging accuracy. Increasing the pulse bandwidth can improve the ranging performance, but the performance is hardly improved any more when the bandwidth is increased beyond a certain level. PRI should be set long enough to guarantee the accurate ranging, because when PRI is shorter than the maximum excess delay of the channel, the ranging accuracy will be deteriorated by inter-pulse interference.