期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
常压氩等离子体改善超高分子量聚乙烯纤维的界面性能 被引量:8
1
作者 姜生 晏雄 蔡永东 《纺织学报》 EI CAS CSCD 北大核心 2006年第11期36-39,51,共5页
改变低温常压氩等离子体处理条件,考察处理后超高分子量聚乙烯纤维束强度与环氧树脂层间剪切应力与各变化因子的关系曲线,通过比较性能的变化,研究氩等离子体处理条件对纤维界面性能的影响。观察处理后纤维束纵向的微观结构,测试用最优... 改变低温常压氩等离子体处理条件,考察处理后超高分子量聚乙烯纤维束强度与环氧树脂层间剪切应力与各变化因子的关系曲线,通过比较性能的变化,研究氩等离子体处理条件对纤维界面性能的影响。观察处理后纤维束纵向的微观结构,测试用最优化工艺参数处理的纤维束制成的纤维增强复合材料的单向性能,进一步论述等离子体处理对纤维束黏合性能的影响。 展开更多
关键词 超高分子量聚乙烯纤维 氩等离子体 层间剪切 纤维增加复合材料
下载PDF
Bond Performance of Fiber Reinforced Polymer (FRP) Bars in Autoclaved Aerated Concrete (AAC)
2
作者 Borvom Israngkura Na Ayudhya Yothin Ungkoon 《Journal of Civil Engineering and Architecture》 2010年第8期37-44,共8页
This paper concerns the bond strength of FRP bars in AAC by the concentric pullout test. Specimens were subjected to compare with mild steel bars. The bond performance including the mode of failure and bond strength w... This paper concerns the bond strength of FRP bars in AAC by the concentric pullout test. Specimens were subjected to compare with mild steel bars. The bond performance including the mode of failure and bond strength was investigated with varying embedment length and surface treatment. Regarding the bond performance, embedment depth has influenced on bond strength as well as the sanded surface. Carbon fiber reinforced polymer (CFRP) pronounced the most promising results with the highest bond strength attained. 展开更多
关键词 Bond strength fiber reinforced polymer autoclaved aerated concrete
下载PDF
Ductility of Timber Beams Strengthened Using Fiber Reinforced Polymer
3
作者 Yusof Ahmad 《Journal of Civil Engineering and Architecture》 2013年第5期535-544,共10页
This research was conducted to investigate the ductility behavior of timber beams strengthened with CFRP (carbon fiber reinforced polymer) plates. The surface to be bonded was spiked by punching small holes of 2 mm ... This research was conducted to investigate the ductility behavior of timber beams strengthened with CFRP (carbon fiber reinforced polymer) plates. The surface to be bonded was spiked by punching small holes of 2 mm in diameter with 10 mm spacing. The aim is to increase bonding capacity by having small studs. Five beams with the dimension of 100 mm x 200 mm x 3,000 mm were tested where one of the beams was used as control beam (unstrengthened). The remaining beams were strengthened with different configurations before tested to failure under four-point loading. The results showed that the ductility was increased as the percentage of CFRP increased. The ductility was dramatically improved where the highest ductility index based on deflection method was 2.2 where the percentage increase was 37.5%, whereas the highest ductility index based on energy method was 3.2 where the percentage increase was 88.2%. From this study, it was found that 0.3% is the optimum value of CFRP area to achieve maximum ductility index. Ductility index obtained from energy method gives higher values when compared to deflection method. All beams in this study did not fail due to peel off or debonding. It was also proved that the spikes that have been made at the wood surface were very effective for bonding. 展开更多
关键词 Carbon fiber reinforced polymer ductility index energy method.
下载PDF
上一页 1 下一页 到第