Based on the transmission theory, the mechanism of the generation of the motor terminal over voltage caused by the long line transmission of PWM pulses in the PWM variable frequency driving system is studied. This p...Based on the transmission theory, the mechanism of the generation of the motor terminal over voltage caused by the long line transmission of PWM pulses in the PWM variable frequency driving system is studied. This paper focuses on the effects of the variant length and characteristic impedance of cables on the over voltage by large numbers of experiment results. In terms of the impedance matching method, a network fixed at motor terminal is designed to reduce the over voltage. The utility of this network is testified by the experiments.展开更多
Several key techniques for a PLL-type frequency synthesizer for WLAN receivers are studied. Its structure is analyzed and the main parameters are proposed. A monolithic LC-tuned voltage controlled oscillator (LCVCO)...Several key techniques for a PLL-type frequency synthesizer for WLAN receivers are studied. Its structure is analyzed and the main parameters are proposed. A monolithic LC-tuned voltage controlled oscillator (LCVCO) with low phase noise is fabricated with TSMC 0.18μm RF (radio frequency) CMOS technology. The measured phase noise is - ll7dBc/Hz at 4MHz off the center frequency of 4. 189GHz. A down-scaling circuit with low power dissipation was fabricated in a TSMC 0.18μm mixed-signal CMOS process. The measured results show that the IC can work well under a 1.8V power supply. Its total power dissipation is only 13mW.展开更多
In operation,risk arising from power transformer faults is of much uncertainty and complicacy.To timely and objectively control the risks,a transformer risk assessment method based on fuzzy analytic hierarchy process(...In operation,risk arising from power transformer faults is of much uncertainty and complicacy.To timely and objectively control the risks,a transformer risk assessment method based on fuzzy analytic hierarchy process(FAHP) and artificial neural network(ANN) from the perspective of accuracy and quickness is proposed.An analytic hierarchy process model for the transformer risk assessment is built by analysis of the risk factors affecting the transformer risk level and the weight relation of each risk factor in transformer risk calculation is analyzed by application of fuzzy consistency judgment matrix;with utilization of adaptive ability and nonlinear mapping ability of the ANN,the risk factors with large weights are used as input of neutral network,and thus intelligent quantitative assessment of transformer risk is realized.The simulation result shows that the proposed method increases the speed and accuracy of the risk assessment and can provide feasible decision basis for the transformer risk management and maintenance decisions.展开更多
In the period 2003-2011, lightning over-voltages accounted for about 47% of the total number of distribution transformer failures observed in the service area ofAES Sul, a power company that operates in the state of R...In the period 2003-2011, lightning over-voltages accounted for about 47% of the total number of distribution transformer failures observed in the service area ofAES Sul, a power company that operates in the state of Rio Grande doSul, in South Brazil. This paper presents the results of an investigation on the influence of the distance between transformer and MV arresters on the surges at the transformer windings caused by direct strikes to the MV network. The analysis, performed through simulations using the Alternative Transients Program, shows that in general higher voltages are produced by subsequent strokes. Although in relation to the primary side the surges transferred to the secondary are much less affected by the distance between transformers and primary arresters, such distance should always be kept as short as possible in order to reduce the probability of occurrence of transformer failures due to over-voltages at the MV bushings.展开更多
文摘Based on the transmission theory, the mechanism of the generation of the motor terminal over voltage caused by the long line transmission of PWM pulses in the PWM variable frequency driving system is studied. This paper focuses on the effects of the variant length and characteristic impedance of cables on the over voltage by large numbers of experiment results. In terms of the impedance matching method, a network fixed at motor terminal is designed to reduce the over voltage. The utility of this network is testified by the experiments.
文摘Several key techniques for a PLL-type frequency synthesizer for WLAN receivers are studied. Its structure is analyzed and the main parameters are proposed. A monolithic LC-tuned voltage controlled oscillator (LCVCO) with low phase noise is fabricated with TSMC 0.18μm RF (radio frequency) CMOS technology. The measured phase noise is - ll7dBc/Hz at 4MHz off the center frequency of 4. 189GHz. A down-scaling circuit with low power dissipation was fabricated in a TSMC 0.18μm mixed-signal CMOS process. The measured results show that the IC can work well under a 1.8V power supply. Its total power dissipation is only 13mW.
基金Project(50977003) supported by the National Natural Science Foundation of China
文摘In operation,risk arising from power transformer faults is of much uncertainty and complicacy.To timely and objectively control the risks,a transformer risk assessment method based on fuzzy analytic hierarchy process(FAHP) and artificial neural network(ANN) from the perspective of accuracy and quickness is proposed.An analytic hierarchy process model for the transformer risk assessment is built by analysis of the risk factors affecting the transformer risk level and the weight relation of each risk factor in transformer risk calculation is analyzed by application of fuzzy consistency judgment matrix;with utilization of adaptive ability and nonlinear mapping ability of the ANN,the risk factors with large weights are used as input of neutral network,and thus intelligent quantitative assessment of transformer risk is realized.The simulation result shows that the proposed method increases the speed and accuracy of the risk assessment and can provide feasible decision basis for the transformer risk management and maintenance decisions.
文摘In the period 2003-2011, lightning over-voltages accounted for about 47% of the total number of distribution transformer failures observed in the service area ofAES Sul, a power company that operates in the state of Rio Grande doSul, in South Brazil. This paper presents the results of an investigation on the influence of the distance between transformer and MV arresters on the surges at the transformer windings caused by direct strikes to the MV network. The analysis, performed through simulations using the Alternative Transients Program, shows that in general higher voltages are produced by subsequent strokes. Although in relation to the primary side the surges transferred to the secondary are much less affected by the distance between transformers and primary arresters, such distance should always be kept as short as possible in order to reduce the probability of occurrence of transformer failures due to over-voltages at the MV bushings.