Exact formulas for the power spectrum and signal-to-noise ratio (SNR) with periodic additive signal arecalculated in the linear system.Then the phenomenon of resonance is studied in detail.We show that resonancepeak a...Exact formulas for the power spectrum and signal-to-noise ratio (SNR) with periodic additive signal arecalculated in the linear system.Then the phenomenon of resonance is studied in detail.We show that resonancepeak and suppressed valley exist in the curves of the SNR versus the coefficient of self-saturation, the net gain and thecross-coupling coefficient of the laser system.展开更多
The temperature rise of He Ⅱ transfer system due to the negative Joule-Thomson(JT)effect is one of the major problems in the He Ⅱ forced flow system design.Negative Joule-Thomson effect of the He Ⅱ forced flow was ...The temperature rise of He Ⅱ transfer system due to the negative Joule-Thomson(JT)effect is one of the major problems in the He Ⅱ forced flow system design.Negative Joule-Thomson effect of the He Ⅱ forced flow was analyzed and calculated in this paper.The temperature rise due to the heat leak along the transfer pipeline was calculated by the simplified equation and was modified by considering the negative Joule-Thomson effect.The modified results were compared with the temperature rise obtained by non-linear differential equations with consideration of the pressure gradient.The results show that the pressure gradient has strong effect on the temperature distribution.The modified results are in good agreement with the values calculated by the complicated equation,which verifies the effectiveness of the simplified equation in calculating the temperature rise when the negative JT effect of He Ⅱ is known.展开更多
基金Supported by the National Natural Science Foundation of China under Grant No.10275025 the Natural Science Foundation of Hubei Province of China under Grant No.2005ABA051
文摘Exact formulas for the power spectrum and signal-to-noise ratio (SNR) with periodic additive signal arecalculated in the linear system.Then the phenomenon of resonance is studied in detail.We show that resonancepeak and suppressed valley exist in the curves of the SNR versus the coefficient of self-saturation, the net gain and thecross-coupling coefficient of the laser system.
基金Sponsored by the National Natural Science Foundation of China(Grant No.10872152)the Ministries and Commissions of Science and Technology of Shanghai Government (Grant No. 03DZ 14014) for Shanghai Jiaotong University
文摘The temperature rise of He Ⅱ transfer system due to the negative Joule-Thomson(JT)effect is one of the major problems in the He Ⅱ forced flow system design.Negative Joule-Thomson effect of the He Ⅱ forced flow was analyzed and calculated in this paper.The temperature rise due to the heat leak along the transfer pipeline was calculated by the simplified equation and was modified by considering the negative Joule-Thomson effect.The modified results were compared with the temperature rise obtained by non-linear differential equations with consideration of the pressure gradient.The results show that the pressure gradient has strong effect on the temperature distribution.The modified results are in good agreement with the values calculated by the complicated equation,which verifies the effectiveness of the simplified equation in calculating the temperature rise when the negative JT effect of He Ⅱ is known.