The objective of this work is to assess the radiation hazards associated gamma rays from building materials. Natural gamma rays activities of natural radionuclide represented mainly by three natural radioactive series...The objective of this work is to assess the radiation hazards associated gamma rays from building materials. Natural gamma rays activities of natural radionuclide represented mainly by three natural radioactive series ^238U, ^235U and ^232Th, and the primordial ^40K in the samples of building materials which consist of bricks, ceramics, marble and gypsum from different areas of eastern Algeria are measured using gamma ray spectrometry. The values of the activities of these radionuclides do not clearly reflect the radiation hazard associated with these materials. Therefore, the radium equivalent (Raeq) concentration is defined taking into account the effectiveness of these isotopes in creating the radiation hazard. Radium equivalent activities, external and internal hazard indices (Hex and Hin) are calculated from the activities of ^226Ra, ^232Th and ^40K for suitability of the materials.展开更多
The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental s...The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental system with the method of optical heterodyne, using the refraction light beam from a prism, and made the experiment. The experimental results are in accordance with the theoretical calculation. It is very useful in some particular case, such as in Negative- Index Materials(NIM), to verify the Doppler Effect with this method.展开更多
We present a new calorimetric method for measuring alternative current(AC)losses of high-temperature superconducting(HTS)tapes by optical fiber Bragg grating(FBG),which is particularly well suited for the AC loss meas...We present a new calorimetric method for measuring alternative current(AC)losses of high-temperature superconducting(HTS)tapes by optical fiber Bragg grating(FBG),which is particularly well suited for the AC loss measurement of Re BCO wires,so-called the second generation(2G)HTS wires.Compared with conventional calorimetric methods,the suggested method is both free of electromagnetic disturbance,magnetic field,and fast as well as simple.Self-field AC losses are measured by the optical FBG method and the conventional lock-in-amplifier(LIA)technique,respectively.The results show that the measured AC loss is in good agreement with those measured by the electric method,thus the presented calorimetric method would be available for measuring the AC loss of 2G wire and is expected to be generalized for the measurement of AC loss or thermal performances of HTS bulk.展开更多
文摘The objective of this work is to assess the radiation hazards associated gamma rays from building materials. Natural gamma rays activities of natural radionuclide represented mainly by three natural radioactive series ^238U, ^235U and ^232Th, and the primordial ^40K in the samples of building materials which consist of bricks, ceramics, marble and gypsum from different areas of eastern Algeria are measured using gamma ray spectrometry. The values of the activities of these radionuclides do not clearly reflect the radiation hazard associated with these materials. Therefore, the radium equivalent (Raeq) concentration is defined taking into account the effectiveness of these isotopes in creating the radiation hazard. Radium equivalent activities, external and internal hazard indices (Hex and Hin) are calculated from the activities of ^226Ra, ^232Th and ^40K for suitability of the materials.
文摘The traditional method of measuring Doppler Effect is either reflection or dispersiion. This article clarifies that it can also verify the Doppler Effect with the refraction method. We have designed the experimental system with the method of optical heterodyne, using the refraction light beam from a prism, and made the experiment. The experimental results are in accordance with the theoretical calculation. It is very useful in some particular case, such as in Negative- Index Materials(NIM), to verify the Doppler Effect with this method.
基金supported by the National Natural Science Foundation of China(Grant No.51477053)the Beijing Education Commissions(Grant No.GJ2013009)
文摘We present a new calorimetric method for measuring alternative current(AC)losses of high-temperature superconducting(HTS)tapes by optical fiber Bragg grating(FBG),which is particularly well suited for the AC loss measurement of Re BCO wires,so-called the second generation(2G)HTS wires.Compared with conventional calorimetric methods,the suggested method is both free of electromagnetic disturbance,magnetic field,and fast as well as simple.Self-field AC losses are measured by the optical FBG method and the conventional lock-in-amplifier(LIA)technique,respectively.The results show that the measured AC loss is in good agreement with those measured by the electric method,thus the presented calorimetric method would be available for measuring the AC loss of 2G wire and is expected to be generalized for the measurement of AC loss or thermal performances of HTS bulk.