A joint direction of arrival (DOA) estimation and phase calibration for synchronous CDMA system with decorrelator are presented. Through decorrelating processing DOAs of the desired users can be estimated independentl...A joint direction of arrival (DOA) estimation and phase calibration for synchronous CDMA system with decorrelator are presented. Through decorrelating processing DOAs of the desired users can be estimated independently and all other resolved signal interferences are eliminated. Emphasis is directed to applications in which sensor phases may be in error. It is shown that accurate phase calibration in conjunction with their use in high resolution DOA estimation can be achieved for the decoupled signals.展开更多
In accordance with the characteristics of wavelength shift detection in fiber grating sensor interrogation system,the wavelength interrogation system which uses linear InGaAs as the spectrum receiver is proposed.Orien...In accordance with the characteristics of wavelength shift detection in fiber grating sensor interrogation system,the wavelength interrogation system which uses linear InGaAs as the spectrum receiver is proposed.Orientation of optic spectrum line affects the silt of volume phase grating and size of InGaAs photosensitive unit,thus the calibration method is needed.Based on an analysis of InGaAs imaging model,least square curve fitting method is proposed to detect spectrum wavelength and InGaAs photosensitive unit position.The experimental results show that the methods are effective and the demodulation system precision is improved.展开更多
Instantaneous Doppler frequency for squint SAR imaging has been found with ChirpScaling Algorithm (CSA). Because the azimuth sample is not perpendicular to the range sample,the range signal must impact on the azimuth ...Instantaneous Doppler frequency for squint SAR imaging has been found with ChirpScaling Algorithm (CSA). Because the azimuth sample is not perpendicular to the range sample,the range signal must impact on the azimuth signal in the squint SAR data processing, andthe different slant range targets have different Doppler frequencies. From the mathematicalmodel of SAR echo signal, this paper carefully analyzes the instantaneous azimuth frequency, theinstantaneous Doppler frequency component of the azimuth frequency and the impact of rangechirp on azimuth frequency, which explains that Doppler frequency should be properly selected forcorrect SAR imaging in the squint SAR. The results of point target simulation experiments showthat the way is reasonable for the squint SAR and can effectively complete range compressionand azimuth focusing, and improve images' quality.展开更多
Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.Howe...Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.However,two significant accelerometer nonlinear errors need to be attacked to improve the modulation effect.Firstly,the asymmetry scale factor inaccuracy enlarges the errors of frequent zero-cross oscillating specific force measured by non-axial accelerometers.Secondly,the traditional linear model of accelerometers can hardly measure the continued or intermittent acceleration accurately.These two nonlinear errors degrade the high-precision specific force measurement and the calibration of nonlinear coefficients because triaxial accelerometers is urgent for the marine navigation.Based on the digital signal sampling property,the square coefficients and cross-coupling coefficients of accelerometers are considered.Meanwhile,the asymmetry scale factors are considered in the I-F conversion unit.Thus,a nonlinear model of specific force measurement is established compared to the linear model.Based on the three-axis turntable,the triaxial gyroscopes are utilized to measure the specific force observation for triaxial accelerometers.Considering the nonlinear combination,the standard calibration parameters and asymmetry factors are separately estimated by a two-step iterative identification procedure.Besides,an efficient specific force calculation model is approximately derived to reduce the real-time computation cost.Simulation results illustrate the sufficient estimation accuracy of nonlinear coefficients.The experiments demonstrate that the nonlinear model shows much higher accuracy than the linear model in both the gravimetry and sway navigation validations.展开更多
the close photogrammetric 3-D coordinate measurement is a newmeasuring technology in the fields of the coordinate measurementmachine (CMM) in recent years. In this method, we usually place sometargets on the measured ...the close photogrammetric 3-D coordinate measurement is a newmeasuring technology in the fields of the coordinate measurementmachine (CMM) in recent years. In this method, we usually place sometargets on the measured object and take image of targets to determinethe object coordinate. The subpixel location of target image plays animportant role in high accuracy 3-D coordinate measuring procedure.In this paper, some subpixel location methods are reviewed and somefactors which affect location precision are analyzed.展开更多
The research on the application of X-ray diffraction in the quantitative analysis of Chinese medicines is rare. The main reason is that the technical problems related to the internal standard and the selection of quan...The research on the application of X-ray diffraction in the quantitative analysis of Chinese medicines is rare. The main reason is that the technical problems related to the internal standard and the selection of quantitative peaks are not well solved, and the accuracy and precision of the results are not satisfactory. This study employed the concept of mass absorption coefficient based on the internal standard method, and the full spectrum fitting and quantitative methods were used to solve the above technical problems. The sample was blended. the internal standard substance of zinc oxide was fully ground, and tablets were prepared by positive pressure method. Under certain instrumental conditions, the PXRD pattern was obtained by scanning. The percentage of gypsum fibrosum in Xiaokening tablet was obtained by quantitative analysis of full spectrum fitting internal standard by TOPAS software. The method was investigated by methodology. At the same time, the method was compared by ion chromatography, and SPSS software was used to make a significant t test on the results of the two methods. After the investigation, the average standard recovery rate of CaSO4-2H2O was 99.06%(RSD = 3.02%);and the recovery rate for simulated samples was 96.7%. The method had good specificity. After statistical analysis, there was no significant difference between the new PXRD method and the traditional method of ion chromatography.展开更多
文摘A joint direction of arrival (DOA) estimation and phase calibration for synchronous CDMA system with decorrelator are presented. Through decorrelating processing DOAs of the desired users can be estimated independently and all other resolved signal interferences are eliminated. Emphasis is directed to applications in which sensor phases may be in error. It is shown that accurate phase calibration in conjunction with their use in high resolution DOA estimation can be achieved for the decoupled signals.
文摘In accordance with the characteristics of wavelength shift detection in fiber grating sensor interrogation system,the wavelength interrogation system which uses linear InGaAs as the spectrum receiver is proposed.Orientation of optic spectrum line affects the silt of volume phase grating and size of InGaAs photosensitive unit,thus the calibration method is needed.Based on an analysis of InGaAs imaging model,least square curve fitting method is proposed to detect spectrum wavelength and InGaAs photosensitive unit position.The experimental results show that the methods are effective and the demodulation system precision is improved.
文摘Instantaneous Doppler frequency for squint SAR imaging has been found with ChirpScaling Algorithm (CSA). Because the azimuth sample is not perpendicular to the range sample,the range signal must impact on the azimuth signal in the squint SAR data processing, andthe different slant range targets have different Doppler frequencies. From the mathematicalmodel of SAR echo signal, this paper carefully analyzes the instantaneous azimuth frequency, theinstantaneous Doppler frequency component of the azimuth frequency and the impact of rangechirp on azimuth frequency, which explains that Doppler frequency should be properly selected forcorrect SAR imaging in the squint SAR. The results of point target simulation experiments showthat the way is reasonable for the squint SAR and can effectively complete range compressionand azimuth focusing, and improve images' quality.
基金Project(61174002)supported by the National Natural Science Foundation of ChinaProject(200897)supported by the Foundation of National Excellent Doctoral Dissertation of PR China+1 种基金Project(NCET-10-0900)supported by the Program for New Century ExcellentTalents in University,ChinaProject(131061)supported by the Fok Ying Tung Education Foundation,China
文摘Single-axis rotation technique is often used in the marine laser inertial navigation system so as to modulate the constant biases of non-axial gyroscopes and accelerometers to attain better navigation performance.However,two significant accelerometer nonlinear errors need to be attacked to improve the modulation effect.Firstly,the asymmetry scale factor inaccuracy enlarges the errors of frequent zero-cross oscillating specific force measured by non-axial accelerometers.Secondly,the traditional linear model of accelerometers can hardly measure the continued or intermittent acceleration accurately.These two nonlinear errors degrade the high-precision specific force measurement and the calibration of nonlinear coefficients because triaxial accelerometers is urgent for the marine navigation.Based on the digital signal sampling property,the square coefficients and cross-coupling coefficients of accelerometers are considered.Meanwhile,the asymmetry scale factors are considered in the I-F conversion unit.Thus,a nonlinear model of specific force measurement is established compared to the linear model.Based on the three-axis turntable,the triaxial gyroscopes are utilized to measure the specific force observation for triaxial accelerometers.Considering the nonlinear combination,the standard calibration parameters and asymmetry factors are separately estimated by a two-step iterative identification procedure.Besides,an efficient specific force calculation model is approximately derived to reduce the real-time computation cost.Simulation results illustrate the sufficient estimation accuracy of nonlinear coefficients.The experiments demonstrate that the nonlinear model shows much higher accuracy than the linear model in both the gravimetry and sway navigation validations.
文摘the close photogrammetric 3-D coordinate measurement is a newmeasuring technology in the fields of the coordinate measurementmachine (CMM) in recent years. In this method, we usually place sometargets on the measured object and take image of targets to determinethe object coordinate. The subpixel location of target image plays animportant role in high accuracy 3-D coordinate measuring procedure.In this paper, some subpixel location methods are reviewed and somefactors which affect location precision are analyzed.
文摘The research on the application of X-ray diffraction in the quantitative analysis of Chinese medicines is rare. The main reason is that the technical problems related to the internal standard and the selection of quantitative peaks are not well solved, and the accuracy and precision of the results are not satisfactory. This study employed the concept of mass absorption coefficient based on the internal standard method, and the full spectrum fitting and quantitative methods were used to solve the above technical problems. The sample was blended. the internal standard substance of zinc oxide was fully ground, and tablets were prepared by positive pressure method. Under certain instrumental conditions, the PXRD pattern was obtained by scanning. The percentage of gypsum fibrosum in Xiaokening tablet was obtained by quantitative analysis of full spectrum fitting internal standard by TOPAS software. The method was investigated by methodology. At the same time, the method was compared by ion chromatography, and SPSS software was used to make a significant t test on the results of the two methods. After the investigation, the average standard recovery rate of CaSO4-2H2O was 99.06%(RSD = 3.02%);and the recovery rate for simulated samples was 96.7%. The method had good specificity. After statistical analysis, there was no significant difference between the new PXRD method and the traditional method of ion chromatography.