A series of human tissue samples and cultured cell lines were formalin-fixed and paraffin-embedded. Specimen cylinder (1.2 -1.8ram) were punched by a modified bone marrow biopsy needle and arrayed on a recipient par...A series of human tissue samples and cultured cell lines were formalin-fixed and paraffin-embedded. Specimen cylinder (1.2 -1.8ram) were punched by a modified bone marrow biopsy needle and arrayed on a recipient paraffin block. Microscopic analysis on the sections from this tissue microarray ( TMA ) block demonstrated that the spots of tissues and cells were well preserved, and the cultured cell samples were successfully embedded from 5 × 104 to 2 × 105 in number. These TMA sections were also suitable for immunohistochemistry and RNA in situ hybridization.展开更多
Objective The aim of the study was to compare the dose to lung volume in the supine and prone posi- tion while designing CyberKnife treatment plans to treat metastatic tumors in the spinous processes of the thoracic v...Objective The aim of the study was to compare the dose to lung volume in the supine and prone posi- tion while designing CyberKnife treatment plans to treat metastatic tumors in the spinous processes of the thoracic vertebrae, and offer a reference for reducing damage to normal tissues. Methods Nine cases of metastatic tumors in the spinous processes of the thoracic vertebrae were selected, and then we designed treatment plans based on the supine and prone positions and compared the results. Results In contrast with the treatment plan based on the prone position, the one for the supine position required 14862-36337 MU more; the lung D5% was 5.20-7.90 Gy higher; and the lung D20% was 2.61-5.73 Gy higher. The difference of dose to spine volume between the two plans was -2.21-2.67 Gy; to the skin volume was -3.93-7.85 Gy; and to the esophagus was 0.28-6.39 Gy. Conclusion The treatment plan based on the prone position of patients can better protect lung tissues than the one based on the supine position, and can also improve the avaUabilitv of beams.展开更多
文摘A series of human tissue samples and cultured cell lines were formalin-fixed and paraffin-embedded. Specimen cylinder (1.2 -1.8ram) were punched by a modified bone marrow biopsy needle and arrayed on a recipient paraffin block. Microscopic analysis on the sections from this tissue microarray ( TMA ) block demonstrated that the spots of tissues and cells were well preserved, and the cultured cell samples were successfully embedded from 5 × 104 to 2 × 105 in number. These TMA sections were also suitable for immunohistochemistry and RNA in situ hybridization.
基金Supported by a grant of 2013 the General Logistics Department Military Logistic Research Project Key Programs(No.BWS13J031)
文摘Objective The aim of the study was to compare the dose to lung volume in the supine and prone posi- tion while designing CyberKnife treatment plans to treat metastatic tumors in the spinous processes of the thoracic vertebrae, and offer a reference for reducing damage to normal tissues. Methods Nine cases of metastatic tumors in the spinous processes of the thoracic vertebrae were selected, and then we designed treatment plans based on the supine and prone positions and compared the results. Results In contrast with the treatment plan based on the prone position, the one for the supine position required 14862-36337 MU more; the lung D5% was 5.20-7.90 Gy higher; and the lung D20% was 2.61-5.73 Gy higher. The difference of dose to spine volume between the two plans was -2.21-2.67 Gy; to the skin volume was -3.93-7.85 Gy; and to the esophagus was 0.28-6.39 Gy. Conclusion The treatment plan based on the prone position of patients can better protect lung tissues than the one based on the supine position, and can also improve the avaUabilitv of beams.