AIM:To use leptin-deficient(ob/ob) mice with demonstrated differences in steatosis levels to test a new diagnostic method using the acoustical structure quantification(ASQ) mode and the associated analytical parameter...AIM:To use leptin-deficient(ob/ob) mice with demonstrated differences in steatosis levels to test a new diagnostic method using the acoustical structure quantification(ASQ) mode and the associated analytical parameter,"focal disturbance ratio"(FD-ratio).METHODS:Nine ob/ob mice,at 5,8,and 12 wk of age(n = 3 in each age group),were used as models for hepatic steatosis.Echo signals obtained from ultrasonography in the mice were analyzed by ASQ,which uses a statistical analysis of echo amplitude to estimate inhomogeneity in the diagnostic region.FD-ratio,as calculated from this analysis,was the focus of the present study.FD-ratio and fat droplet areas and sizes were compared between age groups.RESULTS:No fibrosis or inflammation was observed in any of the groups.The fat droplet area significantly(P < 0.01) increased with age from 1.25% ± 0.28% at 5 wk to 31.07% ± 0.48% at 8 wk to 51.69% ± 3.19% at 12 wk.The median fat droplet size also significantly(P < 0.01) increased with age,from 1.33(0.55-10.52) m at 5 wk,2.82(0.61-44.13) m at 8 wk and 6.34(0.66-81.83) m at 12 wk.The mean FD-ratio was 0.42 ± 0.11 at 5 wk,0.11 ± 0.05 at 8 wk,and 0.03 ± 0.02 at 12 wk.The FD-ratio was significantly lower at 12 wk than at 5 wk and 8 wk(P < 0.01).A significant negative correlation was observed between the FD-ratio and either the fat droplet area(r =-0.7211,P = 0.0017) or fat droplet size(r =-0.9811,P = 0.0052).CONCLUSION:This tool for statistical analysis of signals from ultrasonography using the FD-ratio can be used to accurately quantify fat in vivo in an animal model of hepatic steatosis,and may serve as a quantitative biomarker of hepatic steatosis.展开更多
Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing unde...Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing under vertical loading,the critical factors deciding the initial pretention value were found.According to these factors,a rule for the initial pretension value was put forward.The determination equations were acquired based on the principle of force equilibrium at nodes.The numerical results indicate that the internal force disequilibrium in composite bracings resulted from symmetrical load can be eliminated only in a symmetrical way,so that initial pretention values are decided only by vertical loads.The influencing coefficient leveling method,taking into account interactions between story and story,is accurate and feasible.展开更多
文摘AIM:To use leptin-deficient(ob/ob) mice with demonstrated differences in steatosis levels to test a new diagnostic method using the acoustical structure quantification(ASQ) mode and the associated analytical parameter,"focal disturbance ratio"(FD-ratio).METHODS:Nine ob/ob mice,at 5,8,and 12 wk of age(n = 3 in each age group),were used as models for hepatic steatosis.Echo signals obtained from ultrasonography in the mice were analyzed by ASQ,which uses a statistical analysis of echo amplitude to estimate inhomogeneity in the diagnostic region.FD-ratio,as calculated from this analysis,was the focus of the present study.FD-ratio and fat droplet areas and sizes were compared between age groups.RESULTS:No fibrosis or inflammation was observed in any of the groups.The fat droplet area significantly(P < 0.01) increased with age from 1.25% ± 0.28% at 5 wk to 31.07% ± 0.48% at 8 wk to 51.69% ± 3.19% at 12 wk.The median fat droplet size also significantly(P < 0.01) increased with age,from 1.33(0.55-10.52) m at 5 wk,2.82(0.61-44.13) m at 8 wk and 6.34(0.66-81.83) m at 12 wk.The mean FD-ratio was 0.42 ± 0.11 at 5 wk,0.11 ± 0.05 at 8 wk,and 0.03 ± 0.02 at 12 wk.The FD-ratio was significantly lower at 12 wk than at 5 wk and 8 wk(P < 0.01).A significant negative correlation was observed between the FD-ratio and either the fat droplet area(r =-0.7211,P = 0.0017) or fat droplet size(r =-0.9811,P = 0.0052).CONCLUSION:This tool for statistical analysis of signals from ultrasonography using the FD-ratio can be used to accurately quantify fat in vivo in an animal model of hepatic steatosis,and may serve as a quantitative biomarker of hepatic steatosis.
基金Project of Ministry of Housing and Urban-Rural Development of China(No.2012-K2-28)
文摘Determining initial pretension values of pre-stressed cables is one of the key problems for a steel mega frame and pre-stressed composite bracing structure.Through the mechanical analysis of the composite bracing under vertical loading,the critical factors deciding the initial pretention value were found.According to these factors,a rule for the initial pretension value was put forward.The determination equations were acquired based on the principle of force equilibrium at nodes.The numerical results indicate that the internal force disequilibrium in composite bracings resulted from symmetrical load can be eliminated only in a symmetrical way,so that initial pretention values are decided only by vertical loads.The influencing coefficient leveling method,taking into account interactions between story and story,is accurate and feasible.