The theoretical study of a semi-active predictive control(SAPC) system with magnetorheological(MR) dampers to reduce the responses of seismically excited structures was presented.The SAPC scheme is based on a predicti...The theoretical study of a semi-active predictive control(SAPC) system with magnetorheological(MR) dampers to reduce the responses of seismically excited structures was presented.The SAPC scheme is based on a prediction model of the system response to obtain the control actions by minimizing an object function,which has a function of self-compensation for time delay occurring in real application.A double-ended shear mode combined with a valve mode MR damper,named MRF-04K damper,with the maximum force of 20 kN was designed and manufactured,and parameters of the Bouc-Wen hysteresis model were determined to portray the behavior of this damper.As an example,a 5-story building frame equipped with 2 MRF-04K dampers was presented to demonstrate the performance of the proposed SAPC scheme for addressing time delay and reducing the structural responses under different earthquakes.Comparison with the uncontrolled structure,the passive-off and passive-on cases indicates that both the peak and the norm values of structural responses are all clearly reduced,and the SAPC scheme has a better performance than the two passive cases.展开更多
Tuned liquid damper is one the passive structural control ways which has been used since mid 1980 decade for seismic control in civil engineering. This system is made of one or many tanks filled with fluid, mostly wat...Tuned liquid damper is one the passive structural control ways which has been used since mid 1980 decade for seismic control in civil engineering. This system is made of one or many tanks filled with fluid, mostly water that installed on top of the high raised structure and used to prevent structure vibration. In this article we will show how to make seismic table contain TLD system and analysis the result of using this system in our structure. Results imply that when frequency ratio approaches 1 this system can perform its best in both dissipate energy and increasing structural damping. And also results of these serial experiments are proved compatible with Hunzer linear theory behavior.展开更多
This paper presents a statistically refined Bouc-Wen model of tri-axial interactions for the identification of structural systems under tri-directional seismic excitations. Through limited vibration measurements in th...This paper presents a statistically refined Bouc-Wen model of tri-axial interactions for the identification of structural systems under tri-directional seismic excitations. Through limited vibration measurements in the National Center for Research on Earthquake Engineering in Taiwan conducting model-based experiments, the 3-D Bouc-Wen model has been statistically and repetitively refined using the 95% confidence interval of the estimated structural parameters to determine their statistical significance in a multiple regression setting. When the parameters' confidence interval covers the "null" value, it is statistically sustainable to truncate such parameters. The remaining parameters will repetitively undergo such parameter sifting process for model refinement until all the parameters' statistical significance cannot be further improved. The effectiveness of the refined model has been shown considering the effects of sampling errors, of coupled restoring forces in tri-directions, and of the under-over-parameterization of structural systems. Sifted and estimated parameters such as the stiffness, and its corresponding natural frequency, resulting from the identification methodology developed in this study are carefully observed for system vibration control.展开更多
基金Projects(90815025,51178034) supported by the National Natural Science Foundation of China
文摘The theoretical study of a semi-active predictive control(SAPC) system with magnetorheological(MR) dampers to reduce the responses of seismically excited structures was presented.The SAPC scheme is based on a prediction model of the system response to obtain the control actions by minimizing an object function,which has a function of self-compensation for time delay occurring in real application.A double-ended shear mode combined with a valve mode MR damper,named MRF-04K damper,with the maximum force of 20 kN was designed and manufactured,and parameters of the Bouc-Wen hysteresis model were determined to portray the behavior of this damper.As an example,a 5-story building frame equipped with 2 MRF-04K dampers was presented to demonstrate the performance of the proposed SAPC scheme for addressing time delay and reducing the structural responses under different earthquakes.Comparison with the uncontrolled structure,the passive-off and passive-on cases indicates that both the peak and the norm values of structural responses are all clearly reduced,and the SAPC scheme has a better performance than the two passive cases.
文摘Tuned liquid damper is one the passive structural control ways which has been used since mid 1980 decade for seismic control in civil engineering. This system is made of one or many tanks filled with fluid, mostly water that installed on top of the high raised structure and used to prevent structure vibration. In this article we will show how to make seismic table contain TLD system and analysis the result of using this system in our structure. Results imply that when frequency ratio approaches 1 this system can perform its best in both dissipate energy and increasing structural damping. And also results of these serial experiments are proved compatible with Hunzer linear theory behavior.
文摘This paper presents a statistically refined Bouc-Wen model of tri-axial interactions for the identification of structural systems under tri-directional seismic excitations. Through limited vibration measurements in the National Center for Research on Earthquake Engineering in Taiwan conducting model-based experiments, the 3-D Bouc-Wen model has been statistically and repetitively refined using the 95% confidence interval of the estimated structural parameters to determine their statistical significance in a multiple regression setting. When the parameters' confidence interval covers the "null" value, it is statistically sustainable to truncate such parameters. The remaining parameters will repetitively undergo such parameter sifting process for model refinement until all the parameters' statistical significance cannot be further improved. The effectiveness of the refined model has been shown considering the effects of sampling errors, of coupled restoring forces in tri-directions, and of the under-over-parameterization of structural systems. Sifted and estimated parameters such as the stiffness, and its corresponding natural frequency, resulting from the identification methodology developed in this study are carefully observed for system vibration control.