Computer programs have definitely become indispensable for designing power transformer. Among several applications, computer programs are mostly used for electric field calculation and thus electrical insulation conce...Computer programs have definitely become indispensable for designing power transformer. Among several applications, computer programs are mostly used for electric field calculation and thus electrical insulation concerns. In consequence, studies based on analytical approach to basic studies of correlated problems have become even more important because they form the very basis of knowledge that is necessary to every transformer designer in view of taking all the advantages of computational analyses. On the other hand, one of the most important basic studies consists in the evaluation of voltage surge distribution along transformer windings for which the method of separation of variables has been extensively used thanks to some simplifying assumptions. With this aim, authors have developed and previously published works that show the applicability of an alternative and useful analytical method that is the method of the residues, which requires no simplification to be assumed. In this work, another important step is taken towards proofing the total applicability of this promising method that is through a practical problem. A comparison to the numerical method TLM (transmission line method) is also performed and concordance with TLM and experimental data confirms the proposal of the method of residues can be also applicable to several others problems of electromagnetism.展开更多
Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers o...Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers of pole pairs and damper loops in large hydro-generators would lead to lengthy calculation time,hindering scientific research and engineering application.To deal with this problem,we analyze a theoretical basis for a damper winding simplified model and then propose an equivalent treatment method.Through the analysis of steady-state current harmonic characteristics of generators with different stator winding configurations during the fault,the simplified models suitable for steady-state calculation are derived from two aspects,namely,additional rotor harmonic current frequency characteristics and the relationship of the amplitude as well as the phase of each branch current of the stator.The calculation and experimental results of the two simplified models are then compared to verify the models' correctness.A calculation example of the Three Gorges left bank VGS generator shows few deviations between the calculation results of the simplified model and the original model.Moreover,the calculation time using the simplified model is 1/1500 that using the original model,which provides a more effective tool for on-line fault monitoring.Finally,the sensitivity-verification application of the fault-monitoring scheme based on the stator steady-state unbalanced current RMS is depicted.The result shows that the scheme can monitor two-turn short circuits of field windings in the Three Gorges generator and provide high sensitivity.展开更多
文摘Computer programs have definitely become indispensable for designing power transformer. Among several applications, computer programs are mostly used for electric field calculation and thus electrical insulation concerns. In consequence, studies based on analytical approach to basic studies of correlated problems have become even more important because they form the very basis of knowledge that is necessary to every transformer designer in view of taking all the advantages of computational analyses. On the other hand, one of the most important basic studies consists in the evaluation of voltage surge distribution along transformer windings for which the method of separation of variables has been extensively used thanks to some simplifying assumptions. With this aim, authors have developed and previously published works that show the applicability of an alternative and useful analytical method that is the method of the residues, which requires no simplification to be assumed. In this work, another important step is taken towards proofing the total applicability of this promising method that is through a practical problem. A comparison to the numerical method TLM (transmission line method) is also performed and concordance with TLM and experimental data confirms the proposal of the method of residues can be also applicable to several others problems of electromagnetism.
基金supported by the National Natural Science Foundation of China (Grant No. 50807027)the China Postdoctoral Science Foundation(Grant No. 2012M520155)the Fundamental Research Funds for the Central Universities (Grant No. 2013JBM081)
文摘Inter-turn short circuit of field windings is a common electrical fault of generators.Simulation is an important method of investigating the fault and providing data support for fault monitoring.However,huge numbers of pole pairs and damper loops in large hydro-generators would lead to lengthy calculation time,hindering scientific research and engineering application.To deal with this problem,we analyze a theoretical basis for a damper winding simplified model and then propose an equivalent treatment method.Through the analysis of steady-state current harmonic characteristics of generators with different stator winding configurations during the fault,the simplified models suitable for steady-state calculation are derived from two aspects,namely,additional rotor harmonic current frequency characteristics and the relationship of the amplitude as well as the phase of each branch current of the stator.The calculation and experimental results of the two simplified models are then compared to verify the models' correctness.A calculation example of the Three Gorges left bank VGS generator shows few deviations between the calculation results of the simplified model and the original model.Moreover,the calculation time using the simplified model is 1/1500 that using the original model,which provides a more effective tool for on-line fault monitoring.Finally,the sensitivity-verification application of the fault-monitoring scheme based on the stator steady-state unbalanced current RMS is depicted.The result shows that the scheme can monitor two-turn short circuits of field windings in the Three Gorges generator and provide high sensitivity.