The high temperature heat pump and desiccant wheel(HTHP&DW) system can make full use of heat released from the condenser of heat pump for DW regeneration without additional heat. In this study, DW operation in the...The high temperature heat pump and desiccant wheel(HTHP&DW) system can make full use of heat released from the condenser of heat pump for DW regeneration without additional heat. In this study, DW operation in the HTHP&DW system was investigated experimentally, and the optimization analysis of HTHP&DW system was carried out. The performance of DW had influence on the dehumidification(evaluated by dehumidification and regeneration effectiveness) and cooling load(evaluated by thermal and adiabatic effectiveness). The results show that the enthalpy increase occurred in all the experiments. Compared to the isosteric heat, heat accumulation in the desiccant and matrix material and heat leakage from regeneration side to process side have greater influence on the adiabatic effectiveness. Higher regeneration temperature leads to lower adiabatic effectiveness that increases more cooling load of the system. When the regeneration temperature is 63℃, the maximal dehumidification effectiveness is 35.4% and the satisfied adiabatic effectiveness is 88%, which contributes to the optimal balance between dehumidification and cooling.展开更多
By the unitary transformation method, the instantaneous energy eigenstates of the L-S coupled system in a time-dependent magnetic field, hence the Berry phases, are calculated.
基金Supported by the Danish International DSF Project(No.09-71598)Chinese International Collaboration Project(No.2010DFA62410)
文摘The high temperature heat pump and desiccant wheel(HTHP&DW) system can make full use of heat released from the condenser of heat pump for DW regeneration without additional heat. In this study, DW operation in the HTHP&DW system was investigated experimentally, and the optimization analysis of HTHP&DW system was carried out. The performance of DW had influence on the dehumidification(evaluated by dehumidification and regeneration effectiveness) and cooling load(evaluated by thermal and adiabatic effectiveness). The results show that the enthalpy increase occurred in all the experiments. Compared to the isosteric heat, heat accumulation in the desiccant and matrix material and heat leakage from regeneration side to process side have greater influence on the adiabatic effectiveness. Higher regeneration temperature leads to lower adiabatic effectiveness that increases more cooling load of the system. When the regeneration temperature is 63℃, the maximal dehumidification effectiveness is 35.4% and the satisfied adiabatic effectiveness is 88%, which contributes to the optimal balance between dehumidification and cooling.
文摘By the unitary transformation method, the instantaneous energy eigenstates of the L-S coupled system in a time-dependent magnetic field, hence the Berry phases, are calculated.