This paper presented a scheme of relayed cellular mobile telecommunication network,which only employs fixed digital relays and not more than two-hop relay routes.Power saving potential of the network is deeply studied...This paper presented a scheme of relayed cellular mobile telecommunication network,which only employs fixed digital relays and not more than two-hop relay routes.Power saving potential of the network is deeply studied under the assumption of not occupying additional frequency bands(i.e.relays share the same frequency bands as used by the base stations).Theoretical analysis and simulation results have both shown that,with the same radio coverage requirement,the necessary effective transmission powers in such a relayed network have greatly decreased compared to conventional cellular network.展开更多
Performance of fixed relays in orthogonal frequency division multiple access (0FDMA) systems, especially the coverage and capacity performance at the cell edge, is evaluated in this paper. Two methods, theoretical a...Performance of fixed relays in orthogonal frequency division multiple access (0FDMA) systems, especially the coverage and capacity performance at the cell edge, is evaluated in this paper. Two methods, theoretical analysis and calculation and Monte Carlo simulation, are used for the evaluations. By theoreti- cal analysis and calculation, frequency efficiency equation of a relay is introduced and numerical results are calculated. Monte Carlo simulation results also verify that the calculation method is reasonable. The evaluation shows that a relay can increase system performance to a certain level if it is designed appropriately, otherwise it will be harmful for the system performance, even to reduce it.展开更多
In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slop...In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slope. Modulating the argument of current output from ONLLY testing equipment can make the relay protection device operate, thus, the data used for calculation would be obtained naturally after several trails. In order to make sure how effective that method could be, some experiment data is given as well.展开更多
基金National Science Fund for Creative ResearchGroups(No.60521002)Chinese NationalKey Technology R&D Program(No.2005BA908B02)Science Foundation ofShanghai Municipal Commission of Scienceand Technology,Chinese(No.05dz05802)
文摘This paper presented a scheme of relayed cellular mobile telecommunication network,which only employs fixed digital relays and not more than two-hop relay routes.Power saving potential of the network is deeply studied under the assumption of not occupying additional frequency bands(i.e.relays share the same frequency bands as used by the base stations).Theoretical analysis and simulation results have both shown that,with the same radio coverage requirement,the necessary effective transmission powers in such a relayed network have greatly decreased compared to conventional cellular network.
文摘Performance of fixed relays in orthogonal frequency division multiple access (0FDMA) systems, especially the coverage and capacity performance at the cell edge, is evaluated in this paper. Two methods, theoretical analysis and calculation and Monte Carlo simulation, are used for the evaluations. By theoreti- cal analysis and calculation, frequency efficiency equation of a relay is introduced and numerical results are calculated. Monte Carlo simulation results also verify that the calculation method is reasonable. The evaluation shows that a relay can increase system performance to a certain level if it is designed appropriately, otherwise it will be harmful for the system performance, even to reduce it.
文摘In this paper, a method to calculate the slope of the ratio restraint characteristic of a transformer differential relay protection is proposed. The method allows using some concise but effective means to get the slope. Modulating the argument of current output from ONLLY testing equipment can make the relay protection device operate, thus, the data used for calculation would be obtained naturally after several trails. In order to make sure how effective that method could be, some experiment data is given as well.