Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water whe...Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.展开更多
As demonstrated by former work,the holed casing treatment can be used to expand the stall margin of a centrifugal compressor with unshrouded impeller.In addition,the choked margin can also be expanded as experimental ...As demonstrated by former work,the holed casing treatment can be used to expand the stall margin of a centrifugal compressor with unshrouded impeller.In addition,the choked margin can also be expanded as experimental results indicated.Moreover,the compressor performance,especially the efficiency,on the whole working range is improved.As shown by experiments,the stall margin and choked margin of the compressor are extended,and the maximum efficiency improvement is 14%at the large flowrate of 1.386.Numerical simulations were carried out to analyze the flow in the impeller and in the holes in the case of large flowrate.The results indicate that in large flowrate conditions,there is a low-pressure region on the throat part of the impeller passage,leading to the bypass flows appearing in the holes,which means the flow area at the inlet of the impeller is increased.The bypass flow can also contribute to the decrease of the Mach number at the throat part near the shroud end-wall which implies that the choked margin is expanded.Besides,as the bypass flow would inhibit the development of the vertexes in the tip clearance and suppress the flow recirculation in the shroud end-wall region,both the pressure ratio and efficiency of the compressor are improved,which agrees well with the experiments.展开更多
基金Supported by Major State Basic Research Development Program of China ("973" Program, No. 2009CB219907)the Program for Changjiang Scholars and Innovative Research Team in University (No. IRT0936)
文摘Theoretical and experimental analysis of a new refrigerant mixture BY-3 was conducted based on a single-stage vapor compression refrigeration system. The water-water heat pump system used BY-3 to produce hot water when the low temperature was 20 ℃. The following results were obtained: the highest temperature at the condenser outlet reached about 85 ℃; when the difference between the water temperatures at the condenser outlet and the evaporator inlet was less than 40 ℃, the coefficient of performance (COP) was larger than 4; when the difference reached 55 ℃, the COP still kept 3; the discharge temperature of BY-3 was lower than 100 ℃, and the refrigerant vapor pressure kept lower than 1.8 MPa. When the water temperature at the condenser outlet reached over 85 ℃, nearly a 5 ℃ superheating temperature was maintained.
基金supported by the National Natural Science Foundation of China(Grant No.50776056)the High Technology Research and Development Program of China("863"Program)(Grant No. 2009AA05Z201)
文摘As demonstrated by former work,the holed casing treatment can be used to expand the stall margin of a centrifugal compressor with unshrouded impeller.In addition,the choked margin can also be expanded as experimental results indicated.Moreover,the compressor performance,especially the efficiency,on the whole working range is improved.As shown by experiments,the stall margin and choked margin of the compressor are extended,and the maximum efficiency improvement is 14%at the large flowrate of 1.386.Numerical simulations were carried out to analyze the flow in the impeller and in the holes in the case of large flowrate.The results indicate that in large flowrate conditions,there is a low-pressure region on the throat part of the impeller passage,leading to the bypass flows appearing in the holes,which means the flow area at the inlet of the impeller is increased.The bypass flow can also contribute to the decrease of the Mach number at the throat part near the shroud end-wall which implies that the choked margin is expanded.Besides,as the bypass flow would inhibit the development of the vertexes in the tip clearance and suppress the flow recirculation in the shroud end-wall region,both the pressure ratio and efficiency of the compressor are improved,which agrees well with the experiments.