AIM:To investigate the relationship between blood riboflavin levels and riboflavin transporter 2(RFT2) gene expression in gastric carcinoma(GC) development.METHODS:High-performance liquid chromatography was used to de...AIM:To investigate the relationship between blood riboflavin levels and riboflavin transporter 2(RFT2) gene expression in gastric carcinoma(GC) development.METHODS:High-performance liquid chromatography was used to detect blood riboflavin levels in patients with GC.Real-time fluorogenic quantitative polymerase chain reaction and immunohistochemistry were used to analyze the expression of RFT2 mRNA and protein in samples from 60 GC patients consisting of both tumor and normal tissue.RESULTS:A significant decrease in the RFT2 mRNA levels was detected in GC samples compared with those in the normal mucous membrane(0.398 ± 0.149 vs 1.479 ± 0.587;P = 0.040).Tumors exhibited low RFT2 protein expression(75%,16.7%,8.3% and 0% for no RFT2 staining,weak staining,medium staining and strong staining,respectively),which was significantly lower than that in the normal mucous membrane(10%,16.7%,26.7% and 46.7% for no RFT2 staining,weak staining,medium staining and strong staining,respectively;P < 0.05).Tumors with low RFT2 expression were significantly associated with tumor stage and histological grade.Moreover,a significantly decrease in Uyghur patients was observed compared with Han patients.However,other parameters-gender,tumor location and lymph node metastasis-showed no significant relationship with RFT2 expression.Blood riboflavin levels were reverse correlated with development of GC(1.2000 ± 0.97 569 ng/mL in high tumor stage patients vs 2.5980 ± 1.31 129 ng/mL in low tumor stage patients;P < 0.05).A positive correlation of plasma riboflavin levels with defective expression of RFT2 protein was found in GC patients(2 = 2.619;P = 0.019).CONCLUSION:Defective expression of RFT2 is associated with the development of GC and this may represent a mechanism underlying the decreased plasma riboflavin levels in GC.展开更多
AIM: To evaluate the prevalence of markers of hepatitis B virus (HBV) and hepatitis C virus (HCV) and human immunodeficiency virus (HIV) among blood donors in Kolkata, Eastern India for two consecutive years and to co...AIM: To evaluate the prevalence of markers of hepatitis B virus (HBV) and hepatitis C virus (HCV) and human immunodeficiency virus (HIV) among blood donors in Kolkata, Eastern India for two consecutive years and to conduct a pilot study to explore the presence of HBV DNA among hepatitis B surface antigen (HBsAg) negative but anti-HBc positive blood donors. METHODS: Seroprevalence of HBsAg, anti-HCV and anti-HIV was studied among 113 051 and 106 695 voluntary blood donors screened in 2004 and 2005, respectively. Moreover, a pilot study on 1027 HBsAg negative donors was carried out for evaluating the presence of HBV DNA by PCR on HBsAg negative/anti- HBc positive donors. RESULTS: A statistically significant increase in the prevalence of HBV (1448 vs 1768, P < 0.001), HIV (262 vs 374, P < 0.001), HCV (314 vs 372, P = 0.003) and syphilis (772 vs 853, P = 0.001) infections was noted among blood donors of Kolkata West Bengal in 2005 as compared to 2004. Moreover, the exploratory study on 1027 HBsAg negative donors revealed that 188 (18.3%)of them were anti-HBc positive out of which 21% were positive for HBV DNA. CONCLUSION: The findings of this study underscore the significantly increasing endemicity of hepatitis viruses, syphilis and HIV among the voluntary blood donors of our community. The pilot study indicates a high rate of prevalence of HBV DNA among HBsAg negative/anti-HBc positive donors and thus emphasizes the need for a more sensitive and stringent screening algorithm for blood donations.展开更多
During 2004, a total of 124 batches of HIV antibody ELISAs from domestic and overseas manufacturers, comprising approximately 60 million tests, were tested for quality and released for screening blood in China. The in...During 2004, a total of 124 batches of HIV antibody ELISAs from domestic and overseas manufacturers, comprising approximately 60 million tests, were tested for quality and released for screening blood in China. The inter- and intra-batch variation, specificity, and sensitivity were evaluated using a laboratory panel and clinical samples. The inter-batch variation was less than 15% and only 2 of 12 assays had intra-bateh variation of less than 20% for 4 dilutions of a control specimen. 257 samples confirmed positive for HIV antibody and 4826 negative samples from different regions in China were used to evaluate the sensitivity and specificity of the assays. The results showed that the sensitivity is in the range from 93.7% to 100% for assays sampled directly from the manufacturers, and 91.4%-99.6% for those retrieved from the consumers; the specificity was in the range from 97.88 % to 99.97 %. The testing environment may vary in different regions of China. Therefore, manufaeturers should provide robust assays to satisfy the requirements of these diverse environments, and especially reduce the intra-assay variation and improve the stability of the kits.展开更多
Early adequate fluid loading was the corner stone of hemodynamic optimization for sepsis and septic shock. Meanwhile, recent recommended protocol for fluid resuscitation was increasingly debated on hemodynamic stabili...Early adequate fluid loading was the corner stone of hemodynamic optimization for sepsis and septic shock. Meanwhile, recent recommended protocol for fluid resuscitation was increasingly debated on hemodynamic stability vs risk of overloading. In recent publications, it was found that a priority was often given to hemodynamic stability rather than organ function alternation in the early fluid resusci- tation of sepsis. However, no safety limits were used at all in most of these reports. In this article, the rationality and safety of early aggressive fluid loading for septic patients were discussed. It was concluded that early aggressive fluid loading improved hemodynamics transitorily, but was probably traded off with a follow-up organ function impairment, such as worsening oxygenation by reduction of lung aeration, in a part of septic patients at least. Thus, a safeguard is needed against unnecessary excessive fluids in early aggressive fluid loading for set)tic patients.展开更多
基金Supported by The National Natural Science Foundation of China,No.81160459
文摘AIM:To investigate the relationship between blood riboflavin levels and riboflavin transporter 2(RFT2) gene expression in gastric carcinoma(GC) development.METHODS:High-performance liquid chromatography was used to detect blood riboflavin levels in patients with GC.Real-time fluorogenic quantitative polymerase chain reaction and immunohistochemistry were used to analyze the expression of RFT2 mRNA and protein in samples from 60 GC patients consisting of both tumor and normal tissue.RESULTS:A significant decrease in the RFT2 mRNA levels was detected in GC samples compared with those in the normal mucous membrane(0.398 ± 0.149 vs 1.479 ± 0.587;P = 0.040).Tumors exhibited low RFT2 protein expression(75%,16.7%,8.3% and 0% for no RFT2 staining,weak staining,medium staining and strong staining,respectively),which was significantly lower than that in the normal mucous membrane(10%,16.7%,26.7% and 46.7% for no RFT2 staining,weak staining,medium staining and strong staining,respectively;P < 0.05).Tumors with low RFT2 expression were significantly associated with tumor stage and histological grade.Moreover,a significantly decrease in Uyghur patients was observed compared with Han patients.However,other parameters-gender,tumor location and lymph node metastasis-showed no significant relationship with RFT2 expression.Blood riboflavin levels were reverse correlated with development of GC(1.2000 ± 0.97 569 ng/mL in high tumor stage patients vs 2.5980 ± 1.31 129 ng/mL in low tumor stage patients;P < 0.05).A positive correlation of plasma riboflavin levels with defective expression of RFT2 protein was found in GC patients(2 = 2.619;P = 0.019).CONCLUSION:Defective expression of RFT2 is associated with the development of GC and this may represent a mechanism underlying the decreased plasma riboflavin levels in GC.
基金grants partly from West Bengal State AIDS Prevention & Control Society, Kolkata and partly by Indian Council of Medical Research, New Delhi. Partha Kumar Chandra received a research associateship from West Bengal State AIDS Prevention & Control Society, Kolkata. Arup Banerjee received a senior research fellowship from Indian Council of Medical Research New Delhi Sibnarayan Datta received a senior research fellowship from University Grants Commission, New Delhi
文摘AIM: To evaluate the prevalence of markers of hepatitis B virus (HBV) and hepatitis C virus (HCV) and human immunodeficiency virus (HIV) among blood donors in Kolkata, Eastern India for two consecutive years and to conduct a pilot study to explore the presence of HBV DNA among hepatitis B surface antigen (HBsAg) negative but anti-HBc positive blood donors. METHODS: Seroprevalence of HBsAg, anti-HCV and anti-HIV was studied among 113 051 and 106 695 voluntary blood donors screened in 2004 and 2005, respectively. Moreover, a pilot study on 1027 HBsAg negative donors was carried out for evaluating the presence of HBV DNA by PCR on HBsAg negative/anti- HBc positive donors. RESULTS: A statistically significant increase in the prevalence of HBV (1448 vs 1768, P < 0.001), HIV (262 vs 374, P < 0.001), HCV (314 vs 372, P = 0.003) and syphilis (772 vs 853, P = 0.001) infections was noted among blood donors of Kolkata West Bengal in 2005 as compared to 2004. Moreover, the exploratory study on 1027 HBsAg negative donors revealed that 188 (18.3%)of them were anti-HBc positive out of which 21% were positive for HBV DNA. CONCLUSION: The findings of this study underscore the significantly increasing endemicity of hepatitis viruses, syphilis and HIV among the voluntary blood donors of our community. The pilot study indicates a high rate of prevalence of HBV DNA among HBsAg negative/anti-HBc positive donors and thus emphasizes the need for a more sensitive and stringent screening algorithm for blood donations.
文摘During 2004, a total of 124 batches of HIV antibody ELISAs from domestic and overseas manufacturers, comprising approximately 60 million tests, were tested for quality and released for screening blood in China. The inter- and intra-batch variation, specificity, and sensitivity were evaluated using a laboratory panel and clinical samples. The inter-batch variation was less than 15% and only 2 of 12 assays had intra-bateh variation of less than 20% for 4 dilutions of a control specimen. 257 samples confirmed positive for HIV antibody and 4826 negative samples from different regions in China were used to evaluate the sensitivity and specificity of the assays. The results showed that the sensitivity is in the range from 93.7% to 100% for assays sampled directly from the manufacturers, and 91.4%-99.6% for those retrieved from the consumers; the specificity was in the range from 97.88 % to 99.97 %. The testing environment may vary in different regions of China. Therefore, manufaeturers should provide robust assays to satisfy the requirements of these diverse environments, and especially reduce the intra-assay variation and improve the stability of the kits.
文摘Early adequate fluid loading was the corner stone of hemodynamic optimization for sepsis and septic shock. Meanwhile, recent recommended protocol for fluid resuscitation was increasingly debated on hemodynamic stability vs risk of overloading. In recent publications, it was found that a priority was often given to hemodynamic stability rather than organ function alternation in the early fluid resusci- tation of sepsis. However, no safety limits were used at all in most of these reports. In this article, the rationality and safety of early aggressive fluid loading for septic patients were discussed. It was concluded that early aggressive fluid loading improved hemodynamics transitorily, but was probably traded off with a follow-up organ function impairment, such as worsening oxygenation by reduction of lung aeration, in a part of septic patients at least. Thus, a safeguard is needed against unnecessary excessive fluids in early aggressive fluid loading for set)tic patients.