期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
脱硫烟气自动监控设备的网状流量测量方法 被引量:2
1
作者 王金雷 《环境保护与循环经济》 2014年第8期68-69,共2页
随着环保部门及企业对脱硫烟气流量准确性的要求越来越高,部分企业流量计安装位置无法准确反映企业的实际工况,而采用网状测量烟气流量可以较好地解决此类问题。根据各测量截面尺寸的大小、直管段长短等因素确定测量点数,将多个测量点... 随着环保部门及企业对脱硫烟气流量准确性的要求越来越高,部分企业流量计安装位置无法准确反映企业的实际工况,而采用网状测量烟气流量可以较好地解决此类问题。根据各测量截面尺寸的大小、直管段长短等因素确定测量点数,将多个测量点等截面有机地组装在一起,测得截面的平均速度,计算出风量。详细地介绍了网状测量烟气流量方法在污染源自动监控烟气流量测量方面的原理及优势,并就该技术的应用前景进行了分析和展望。 展开更多
关键词 脱硫烟气 流量 网状测量 准确性
下载PDF
Electrochemical behavior of mesh and plate oxide coated anodes during zinc electrowinning 被引量:2
2
作者 张伟 Michael ROBICHAUD +1 位作者 Edward GHALI Georges HOULACHI 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2016年第2期589-598,共10页
The catalytic performance of two oxides coated anodes (OCSs) meshes and one OCA plate was investigated in a zinc electrowinning electrolyte at 38 ℃. Their electrochemical behaviors were compared with that of a conv... The catalytic performance of two oxides coated anodes (OCSs) meshes and one OCA plate was investigated in a zinc electrowinning electrolyte at 38 ℃. Their electrochemical behaviors were compared with that of a conventional Pb-0.7%Ag alloy anode. Electrochemical measurements such as cyclic voltammetric, galvanostatic, potentiodynamic, open-circuit potential (OCP) and in situ electrochemical noise measurements were considered. After 2 h of OCP test, the linear polarization shows that the corrosion current density of the Ti/(IrO2-Ta2O5) mesh electrode is the lowest (3.37μA/cm^2) among the three OCAs and shows excellent performance. Additionally, after 24 h of galvanostatic polarization at 50 mA/cm^2and 38 ℃, the Ti/MnO2mesh anode has the highest potential (1.799 V), followed by the Ti/(IrO2-Ta2O5) plate (1.775 V) and Ti/(IrO2-Ta2O5) mesh (1.705 V) anodes. After 24 h of galvanostatic polarization followed by 16 h of decay, the linear polarization method confirms the sequence obtained after 2 h of OCP test, and the Ti/(IrO2-Ta2O5) mesh attains the lowest corrosion current density. The Ti/(IrO2-Ta2O5) mesh anode also shows better performance after 24 h of galvanostatic polarization with the overpotential lower than that of the conventional Pb-Ag anode by about 245 mV. 展开更多
关键词 oxides coated anode MESH PLATE electrochemical measurement electrochemical behavior
下载PDF
A Trusted Measurement Scheme Suitable for the Clients in the Trusted Network 被引量:3
3
作者 GONG Bei ZHANG Jianbiao +1 位作者 YE Xiaolie SHEN Changxiang 《China Communications》 SCIE CSCD 2014年第4期143-153,共11页
The trusted network connection is a hot spot in trusted computing field and the trust measurement and access control technology are used to deal with network security threats in trusted network.But the trusted network... The trusted network connection is a hot spot in trusted computing field and the trust measurement and access control technology are used to deal with network security threats in trusted network.But the trusted network connection lacks fine-grained states and real-time measurement support for the client and the authentication mechanism is difficult to apply in the trusted network connection,it is easy to cause the loss of identity privacy.In order to solve the abovedescribed problems,this paper presents a trust measurement scheme suitable for clients in the trusted network,the scheme integrates the following attributes such as authentication mechanism,state measurement,and real-time state measurement and so on,and based on the authentication mechanism and the initial state measurement,the scheme uses the realtime state measurement as the core method to complete the trust measurement for the client.This scheme presented in this paper supports both static and dynamic measurements.Overall,the characteristics of this scheme such as fine granularity,dynamic,real-time state measurement make it possible to make more fine-grained security policy and therefore it overcomes inadequacies existing in the current trusted network connection. 展开更多
关键词 trusted computing trusted network AUTHENTICATION state measurement real-time measurement
下载PDF
上一页 1 下一页 到第