We read the article entitled Coronary revascularization in the elderly with stable angina with interest. In the guidelines related to stable coronary artery disease, it does not exist any age-related net proposals for...We read the article entitled Coronary revascularization in the elderly with stable angina with interest. In the guidelines related to stable coronary artery disease, it does not exist any age-related net proposals for the patients with stable angina pectoris.展开更多
Wireless mesh network (WMN) is a new multi-hop network for broadband accessing to intemet. However, there exists a server unfairness problem based on different hop distances in WMN. To solve this problem, the unfair...Wireless mesh network (WMN) is a new multi-hop network for broadband accessing to intemet. However, there exists a server unfairness problem based on different hop distances in WMN. To solve this problem, the unfairness issue was analyzed in test-bed experiment and NS2 simulation. A dynamic queue management scheme E-QMMN was proposed, which allocates the queue buffer according to the hop distance of every flow. The experimental results show that the proposed scheme can not only increase the hop distance fairness of the legacy scheme at most 50%, but also reduce the average round trip time at least 29% in congested WMN environments.展开更多
In this paper, online security warning and risk assessment of power grid are proposed, based on data from EMS (Energy Management System), combined with information of real-time operation state, component status and ...In this paper, online security warning and risk assessment of power grid are proposed, based on data from EMS (Energy Management System), combined with information of real-time operation state, component status and external operating environment. It combines the two factors, contingency likelihood and severity, that determine system reliability, into risk indices on different loads and operation modes, which provide precise evaluation of the power grid's security performance. According to these indices, it can know the vulnerable area of the system and whether the normal operating mode or repair mode is over-limited or not, and provide decision-making support for dispatchers. Common cause outages and equipment-aging are considered in terms of the establishment of outage model. Multiple risk indices are defined in order to reflect the risk level of the power grid more comprehensively.展开更多
文摘We read the article entitled Coronary revascularization in the elderly with stable angina with interest. In the guidelines related to stable coronary artery disease, it does not exist any age-related net proposals for the patients with stable angina pectoris.
基金Projects(61163060,61103204,60963022) supported by the National Natural Science Foundation of ChinaProject(D018023) supported by the Natural Science Foundation of Guangxi Province,ChinaPostdoctoral Funding of Central South University,China
文摘Wireless mesh network (WMN) is a new multi-hop network for broadband accessing to intemet. However, there exists a server unfairness problem based on different hop distances in WMN. To solve this problem, the unfairness issue was analyzed in test-bed experiment and NS2 simulation. A dynamic queue management scheme E-QMMN was proposed, which allocates the queue buffer according to the hop distance of every flow. The experimental results show that the proposed scheme can not only increase the hop distance fairness of the legacy scheme at most 50%, but also reduce the average round trip time at least 29% in congested WMN environments.
文摘In this paper, online security warning and risk assessment of power grid are proposed, based on data from EMS (Energy Management System), combined with information of real-time operation state, component status and external operating environment. It combines the two factors, contingency likelihood and severity, that determine system reliability, into risk indices on different loads and operation modes, which provide precise evaluation of the power grid's security performance. According to these indices, it can know the vulnerable area of the system and whether the normal operating mode or repair mode is over-limited or not, and provide decision-making support for dispatchers. Common cause outages and equipment-aging are considered in terms of the establishment of outage model. Multiple risk indices are defined in order to reflect the risk level of the power grid more comprehensively.