This paper proposes a method for transformer fault detection system based on GSM network, through the current transformer, voltage sensor information, the known fault information attribute conditions, and the feedback...This paper proposes a method for transformer fault detection system based on GSM network, through the current transformer, voltage sensor information, the known fault information attribute conditions, and the feedback weighted coefficient through the adaptive feed forward, that can obtain high fault information attributes, thus filtering interference factors and timely get fault information properties. It solves the traditional transformer can only judge general fault and fault real-time alarm by GSM network, the system also can measure the transformer oil temperature and oil temperature alarm in super high temperature, to detect the power transformer operation parameters, and the fault running state (over-current, over-voltage, under-voltage, warning). The actual test system show that, diagnosis ability of fault signal separation ability and small signal identification increases 17%. also meet the requirements of real-time.展开更多
The paper design intelligent monitoring system of aquaculture based on CC2530 wireless sensor networks, combined with the actual situation, takes the tilapia as an example to analyze detailed of the process in intelli...The paper design intelligent monitoring system of aquaculture based on CC2530 wireless sensor networks, combined with the actual situation, takes the tilapia as an example to analyze detailed of the process in intelligent high density culture. At the same time, the paper introduced each function module of aquaculture for the intelligent monitoring system and formulate control standard according to the aquatic products in different growth stages of demand, through the real-time monitoring of aquaculture environment, measured the standard parameter setting of parameters and the system automatically adjusts the aquaculture environment comparison. The test results show that the temperature error is in the range of 0.5 ℃, dissolved oxygen amount of error is in the range of 0.3mg/L, the error of pH value is within 0.3, system data transmission correct rate is more than 98%.展开更多
the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fl...the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fluctuate, that will cause the system to detect the fault isolation ability of confusion and small fault signal is not strong; The article propose a method of power network fault detection for based on GSM, Through the underlying sensing equipment acquisition abnormal information of current, voltage power in the network and GSM networking scheme can filter the interference factors in extraction of fault information from and attribute value. The embedded gateway take STM32 chip as the core to monitoring data processing, to achieve a unified data management and user remote access, realizing method of system software are given, to construct the monitor management information platform. The actual test system show that, identification diagnosis ability of fault signal separation ability and small signal increases 17%, also meet the requirements.展开更多
文摘This paper proposes a method for transformer fault detection system based on GSM network, through the current transformer, voltage sensor information, the known fault information attribute conditions, and the feedback weighted coefficient through the adaptive feed forward, that can obtain high fault information attributes, thus filtering interference factors and timely get fault information properties. It solves the traditional transformer can only judge general fault and fault real-time alarm by GSM network, the system also can measure the transformer oil temperature and oil temperature alarm in super high temperature, to detect the power transformer operation parameters, and the fault running state (over-current, over-voltage, under-voltage, warning). The actual test system show that, diagnosis ability of fault signal separation ability and small signal identification increases 17%. also meet the requirements of real-time.
文摘The paper design intelligent monitoring system of aquaculture based on CC2530 wireless sensor networks, combined with the actual situation, takes the tilapia as an example to analyze detailed of the process in intelligent high density culture. At the same time, the paper introduced each function module of aquaculture for the intelligent monitoring system and formulate control standard according to the aquatic products in different growth stages of demand, through the real-time monitoring of aquaculture environment, measured the standard parameter setting of parameters and the system automatically adjusts the aquaculture environment comparison. The test results show that the temperature error is in the range of 0.5 ℃, dissolved oxygen amount of error is in the range of 0.3mg/L, the error of pH value is within 0.3, system data transmission correct rate is more than 98%.
文摘the power network fault detection system can only analyze all kinds of fault signal in stationary sequence: the internal grid and external disturbance presents degeneration, tiny, signal intensity changes randomly fluctuate, that will cause the system to detect the fault isolation ability of confusion and small fault signal is not strong; The article propose a method of power network fault detection for based on GSM, Through the underlying sensing equipment acquisition abnormal information of current, voltage power in the network and GSM networking scheme can filter the interference factors in extraction of fault information from and attribute value. The embedded gateway take STM32 chip as the core to monitoring data processing, to achieve a unified data management and user remote access, realizing method of system software are given, to construct the monitor management information platform. The actual test system show that, identification diagnosis ability of fault signal separation ability and small signal increases 17%, also meet the requirements.