基于FBS的虚拟血管支架置入模型 被引量:2
1
作者 黄晨曦 郝泳涛 +1 位作者 邢浩威 陈飞 《系统仿真学报》 CAS CSCD 北大核心 2018年第7期2622-2629,共8页
血管支架介入手术能有效扩张狭窄的冠状动脉。医生根据经验对病人血管的二维影像进行分析,并选取支架进行置入。结合功能—行为—结构模型开展血管支架置入模型研究。提出了利用虚拟现实语言建立支架三维模型,模拟支架置入过程。通过虚... 血管支架介入手术能有效扩张狭窄的冠状动脉。医生根据经验对病人血管的二维影像进行分析,并选取支架进行置入。结合功能—行为—结构模型开展血管支架置入模型研究。提出了利用虚拟现实语言建立支架三维模型,模拟支架置入过程。通过虚拟现实交互技术结合FBS产品设计方法,对虚拟支架选型和置入过程不断调整,直到达到最优过程。该原型系统能帮助病人建立个性化置入模型,针对病人血管的特异性准确进行支架选型,还能辅助医生开展虚拟现实环境下的支架置入手术训练。 展开更多
关键词 血管支架 功能-行为-结构模型 虚拟现实 置入模型
下载PDF
Rapid prototyping drill guide template for lumbar pedicle screw placement 被引量:25
2
作者 陆声 徐永清 +4 位作者 张元智 李严兵 师继红 陈国平 陈玉兵 《Chinese Journal of Traumatology》 CAS 2009年第3期177-180,共4页
Objective: To develop a novel method of spinal pedical stereotaxy by reverse engineering and rapid prototyping techniques, and to validate its accuracy by experimental and clinical studies. Methods: A 3D reconstruc... Objective: To develop a novel method of spinal pedical stereotaxy by reverse engineering and rapid prototyping techniques, and to validate its accuracy by experimental and clinical studies. Methods: A 3D reconstruction model for the desired lumbar vertebra was generated by using the Mimics 10.11 software, and the optimal screw size and orientation were determined using the reverse engineering software. Afterwards, a drill template was created by reverse engineering principle, whose surface was the antitemplate of the vertebral surface. The drill template and its corresponding vertebra were manufactured using the rapid prototyping technique. Results: The accuracy of the drill template was confinned by drilling screw trajectory into the vertebral biomodel preoperatively. This method also showed its ability to customize the placement and size of each screw based on the unique morphology of the lumbar vertebra.The drill template fits the postural surface of the vertebra very well in the cadaver experiment. Postoperative CT scans for controlling the pedicle bore showed that the personalized template had a high precision in cadaver experiment and clinical application. No misplacement occurred by using the personalized template. During surgery, no additional computer assistance was needed. Conclusions: The authors have developed a novel drill template for lumbar pedicle screw placement with good applicability and high accuracy. The potential use of drill templates to place lumbar pedicle screws is promising, Our methodology appears to provide an accurate technique and trajectory for pedicle screw placement in the lumbar spine. 展开更多
关键词 NEURONAVIGATION TEMPLATE Lumbar vertebrae Bone screws
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部