The transmission of transverse vibrational energy of a vertically rigid beam plate coupled structure is analyzed to get the theoretical results of coupling loss factor(CLF), a very important parameter in statistical ...The transmission of transverse vibrational energy of a vertically rigid beam plate coupled structure is analyzed to get the theoretical results of coupling loss factor(CLF), a very important parameter in statistical energy analysis(SEA). The modal analysis method is used to discuss the vibration energy of the typical model, as well as the power flow between the two subsystems. Furthermore, the resolution to the coupling loss factor is also derived and compared with the measured values. The analytical results of the coupling loss factor agree with the measured ones fully, this new resolution is significant for the application of SEA.展开更多
The structural and electrical properties of lead free Srx-xLax(Tio.sFeo.5)O3 (SLTFO) prepared by standard solid state reaction technique were studied. The X-ray diffraction analysis confirmed the formation of a si...The structural and electrical properties of lead free Srx-xLax(Tio.sFeo.5)O3 (SLTFO) prepared by standard solid state reaction technique were studied. The X-ray diffraction analysis confirmed the formation of a single-phase cubic perovskite structure. The compositional dependence of lattice constant, density and microstructural studies show that they vary significantly with La3+ content. When measured at 10 kHz, all the compositions of SLTFO at room temperature exhibit a high permittivity (about 104) and low dielectric loss (about 10-3). SLTFO also display minimum dielectric loss within the lower and higher limits of frequency, indicating that the samples are of good quality. It is concluded from the calculated ac conductivity that the conduction is due to mixed polarons hopping. The complex impedance plot exhibits a tendency of forming a single semicircular arc for all compositions, which implies a dominance of grain boundary resistance on the impedance. Impedance parameters were determined by fitting the experimental data with Cole-Cole empirical formula. The results of the present experiment indicate that the lead free SLTFO materials with higher permittivity and lower dielectric loss have possible practical applications.展开更多
The main objective of this paper is to show an overview analysis of market power issues.Market power reflects the scarcity of power supply.It is the ability of a particular seller or group of sellers to maintain price...The main objective of this paper is to show an overview analysis of market power issues.Market power reflects the scarcity of power supply.It is the ability of a particular seller or group of sellers to maintain prices profitably above competitive levels for a significant period of time.Because the electric power system has its own characteristics that are different to other economic systems,both physical factors and economic factors of power system are key elements on this definition.We study some cases here,including different line limit levels,load levels and bid strategy through a market model based on OPF (optimal power flow) with a decommitment algorithm.展开更多
In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a vari...In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a variety of transformers are studied, and the applicable scope of the conversion formula is discussed emphatically, combined with the test results are analyzed of transformer insulation resistance value to temperature and oiliness and dielectric loss tangent to temperature and oiliness, and puts forward suggestions on how to improve the insulation performance of transformer.展开更多
High-temperature superconductors in superconductor apparatuses are subjected to mechanical strains under operating conditions.These strains cause the degradation of the critical current densities and influence AC loss...High-temperature superconductors in superconductor apparatuses are subjected to mechanical strains under operating conditions.These strains cause the degradation of the critical current densities and influence AC losses in the superconductors.Based on the dynamic process of thermomagnetic interaction,we report the results of numerical analysis of AC losses in an infinite high-temperature superconducting slab subjected to a uniform in-plane strain in an alternating external magnetic field parallel to the sample surface.The numerical analysis shows the details of electromagnetic phenomena in the slab and the dependences of AC loss on various external parameters including the uniform strain in the slab and the amplitude and frequency of the external magnetic field.In this paper,we find that whether the magnetic field fully penetrates the superconductor is the key factor that influences the features of AC loss.When the magnetic field cannot fully penetrate the superconductor,the loss rises with increasing strain or decreasing frequency.When the magnetic field can fully penetrate the superconductor,the feature is just opposite.We also analyze the effects of periodic strain on AC loss.It is interesting to find that when the periodic strain frequency equals the external magnetic field frequency,the AC loss reaches the maximum,regardless if the magnetic field fully penetrates the superconductor or not.展开更多
文摘The transmission of transverse vibrational energy of a vertically rigid beam plate coupled structure is analyzed to get the theoretical results of coupling loss factor(CLF), a very important parameter in statistical energy analysis(SEA). The modal analysis method is used to discuss the vibration energy of the typical model, as well as the power flow between the two subsystems. Furthermore, the resolution to the coupling loss factor is also derived and compared with the measured values. The analytical results of the coupling loss factor agree with the measured ones fully, this new resolution is significant for the application of SEA.
基金Project supported by CASR of Bangladesh University of Engineering and Technology(BUET)
文摘The structural and electrical properties of lead free Srx-xLax(Tio.sFeo.5)O3 (SLTFO) prepared by standard solid state reaction technique were studied. The X-ray diffraction analysis confirmed the formation of a single-phase cubic perovskite structure. The compositional dependence of lattice constant, density and microstructural studies show that they vary significantly with La3+ content. When measured at 10 kHz, all the compositions of SLTFO at room temperature exhibit a high permittivity (about 104) and low dielectric loss (about 10-3). SLTFO also display minimum dielectric loss within the lower and higher limits of frequency, indicating that the samples are of good quality. It is concluded from the calculated ac conductivity that the conduction is due to mixed polarons hopping. The complex impedance plot exhibits a tendency of forming a single semicircular arc for all compositions, which implies a dominance of grain boundary resistance on the impedance. Impedance parameters were determined by fitting the experimental data with Cole-Cole empirical formula. The results of the present experiment indicate that the lead free SLTFO materials with higher permittivity and lower dielectric loss have possible practical applications.
基金This paper supported by National Natural Science Foundation of China (50079006).
文摘The main objective of this paper is to show an overview analysis of market power issues.Market power reflects the scarcity of power supply.It is the ability of a particular seller or group of sellers to maintain prices profitably above competitive levels for a significant period of time.Because the electric power system has its own characteristics that are different to other economic systems,both physical factors and economic factors of power system are key elements on this definition.We study some cases here,including different line limit levels,load levels and bid strategy through a market model based on OPF (optimal power flow) with a decommitment algorithm.
文摘In view of long-term transformer insulation resistance and dielectric loss measurement, measurement and according to the national standard formula conversion values are not completely consistent, in this paper, a variety of transformers are studied, and the applicable scope of the conversion formula is discussed emphatically, combined with the test results are analyzed of transformer insulation resistance value to temperature and oiliness and dielectric loss tangent to temperature and oiliness, and puts forward suggestions on how to improve the insulation performance of transformer.
基金supported by the National Natural Science Foundation of China(Grant Nos.11032006,11121202 and 11202087)National Key Project of Magneto-Constrained Fusion Energy Development Program(Grant No.2013GB110002)
文摘High-temperature superconductors in superconductor apparatuses are subjected to mechanical strains under operating conditions.These strains cause the degradation of the critical current densities and influence AC losses in the superconductors.Based on the dynamic process of thermomagnetic interaction,we report the results of numerical analysis of AC losses in an infinite high-temperature superconducting slab subjected to a uniform in-plane strain in an alternating external magnetic field parallel to the sample surface.The numerical analysis shows the details of electromagnetic phenomena in the slab and the dependences of AC loss on various external parameters including the uniform strain in the slab and the amplitude and frequency of the external magnetic field.In this paper,we find that whether the magnetic field fully penetrates the superconductor is the key factor that influences the features of AC loss.When the magnetic field cannot fully penetrate the superconductor,the loss rises with increasing strain or decreasing frequency.When the magnetic field can fully penetrate the superconductor,the feature is just opposite.We also analyze the effects of periodic strain on AC loss.It is interesting to find that when the periodic strain frequency equals the external magnetic field frequency,the AC loss reaches the maximum,regardless if the magnetic field fully penetrates the superconductor or not.