An experimental study of the thermal characteristics of an existing office building with double skin facade DSF were conducted in hot summer daytime in Nanjing China. The temperature distributions of the DSF and indoo...An experimental study of the thermal characteristics of an existing office building with double skin facade DSF were conducted in hot summer daytime in Nanjing China. The temperature distributions of the DSF and indoor environment were measured at different control modes of DSF.The results show that the energy consumption of the air conditioning system in room B with opened exterior vents a closed interior facade and an air cavity with shading was 21.0% less than that in room A with closed exterior vents a closed interior facade and air cavity without shading in 9.5 h. The temperature distributions of the DSF and indoor environment in both horizontal and vertical directions were decisively influenced by shading conditions. The usage of shading devices strengthens the stack effect on the air cavity. Compared to room A the temperature distribution in room B is more uniform with smaller fluctuations.Meanwhile the problem of overheating in the air cavity of the DSF is still present in all tested conditions.展开更多
Seven distributors with different configurations are designed and optimized by constructal approach. Their flow distribution performance and energy dissipation are investigated and compared by computational fluid dyna...Seven distributors with different configurations are designed and optimized by constructal approach. Their flow distribution performance and energy dissipation are investigated and compared by computational fluid dynamics (CFD) simulation. The reliability of CFD simulation is verified by experiments on the distributor that has all distributing rectangle channels on a plate. The results show that the symmetry of the distributing channels has decisive influence on the performance of flow distribution. Increasing the generations of channel branching will improve the flow distribution uniformity, but on the other hand increase the energy dissipation. Among all the seven constructal distributors, the distributor that has dichotomy configuration, Y-type junctions and straight interconnecting channels, is recommended for its better flow distribution performance and less energy dissipation.展开更多
Energy is the determinant factor for the survival of Mobile Sensor Networks(MSN).Based on the analysis of the energy distribution in this paper,a two-phase relocation algorithm is proposed based on the balance between...Energy is the determinant factor for the survival of Mobile Sensor Networks(MSN).Based on the analysis of the energy distribution in this paper,a two-phase relocation algorithm is proposed based on the balance between the energy provision and energy consumption distribution.Our main objectives are to maximize the coverage percentage and to minimize the total distance of node movements.This algorithm is designed to meet the requirement of non-uniform distribution network applications,to extend the lifetime of MSN and to simplify the design of the routing protocol.In ad-dition,test results show the feasibility of our proposed relocation algorithm.展开更多
For evaluate the aerodynamic character of the turbine cascades which have the aft-loaded profile, the experimental investigation was carried out on the low speed annular wind tunnel. And the detailed measurements of t...For evaluate the aerodynamic character of the turbine cascades which have the aft-loaded profile, the experimental investigation was carried out on the low speed annular wind tunnel. And the detailed measurements of the aerodynamic parameters were made from upstream to downstream of the two type turbine cascades, the one is the conventional straight blades cascade, the other is the curved blades cascades. The static pressure distributions on the endwall and the blade surface were also carried out. The influence of the aft-loaded profile and the curved blade on the development of loss and the pressure distribution was discussed, and analyses the different flow phenomena and mechanism in two type turbine cascades.展开更多
基金The National Natural Science Foundation of China(No.51308295,51206080)China Postdoctoral Science Foundation(No.2013M531368)
文摘An experimental study of the thermal characteristics of an existing office building with double skin facade DSF were conducted in hot summer daytime in Nanjing China. The temperature distributions of the DSF and indoor environment were measured at different control modes of DSF.The results show that the energy consumption of the air conditioning system in room B with opened exterior vents a closed interior facade and an air cavity with shading was 21.0% less than that in room A with closed exterior vents a closed interior facade and air cavity without shading in 9.5 h. The temperature distributions of the DSF and indoor environment in both horizontal and vertical directions were decisively influenced by shading conditions. The usage of shading devices strengthens the stack effect on the air cavity. Compared to room A the temperature distribution in room B is more uniform with smaller fluctuations.Meanwhile the problem of overheating in the air cavity of the DSF is still present in all tested conditions.
基金Supported by the National Natural Science Foundation of China (20476026), the Program for New Century Excellent Talents in University (05-0416), the Creative Team Development Project of Ministry of Education (IRT0721), and the 111 Project of Ministry of Education and State Administration of Foreign Experts Affairs (B08021 ).
文摘Seven distributors with different configurations are designed and optimized by constructal approach. Their flow distribution performance and energy dissipation are investigated and compared by computational fluid dynamics (CFD) simulation. The reliability of CFD simulation is verified by experiments on the distributor that has all distributing rectangle channels on a plate. The results show that the symmetry of the distributing channels has decisive influence on the performance of flow distribution. Increasing the generations of channel branching will improve the flow distribution uniformity, but on the other hand increase the energy dissipation. Among all the seven constructal distributors, the distributor that has dichotomy configuration, Y-type junctions and straight interconnecting channels, is recommended for its better flow distribution performance and less energy dissipation.
文摘Energy is the determinant factor for the survival of Mobile Sensor Networks(MSN).Based on the analysis of the energy distribution in this paper,a two-phase relocation algorithm is proposed based on the balance between the energy provision and energy consumption distribution.Our main objectives are to maximize the coverage percentage and to minimize the total distance of node movements.This algorithm is designed to meet the requirement of non-uniform distribution network applications,to extend the lifetime of MSN and to simplify the design of the routing protocol.In ad-dition,test results show the feasibility of our proposed relocation algorithm.
文摘For evaluate the aerodynamic character of the turbine cascades which have the aft-loaded profile, the experimental investigation was carried out on the low speed annular wind tunnel. And the detailed measurements of the aerodynamic parameters were made from upstream to downstream of the two type turbine cascades, the one is the conventional straight blades cascade, the other is the curved blades cascades. The static pressure distributions on the endwall and the blade surface were also carried out. The influence of the aft-loaded profile and the curved blade on the development of loss and the pressure distribution was discussed, and analyses the different flow phenomena and mechanism in two type turbine cascades.