Partially replacing polyvinyl-alcohol(PVA)fibers with polypropylene(PP)fibers in strain-hardening cementitious composites(fiber hybridization)modify certain mechanical properties of these materials.The hybridization b...Partially replacing polyvinyl-alcohol(PVA)fibers with polypropylene(PP)fibers in strain-hardening cementitious composites(fiber hybridization)modify certain mechanical properties of these materials.The hybridization based on the introduction of low-modulus hydrophobic polypropylene fibers improves the ductility and the strain-hardening behavior of the cementitious composites containing polyvinyl-alcohol fibers of different types(PVA-SHCC).Pull-out tests indicate that adding PP fibers increases the energy capacity of the hybrid composite with respect to the material containing only PVA fibers under tensile loading,and PP-fiber geometry(i.e.,section shape and length)is a key factor in enhancing the strain capacity.展开更多
文摘Partially replacing polyvinyl-alcohol(PVA)fibers with polypropylene(PP)fibers in strain-hardening cementitious composites(fiber hybridization)modify certain mechanical properties of these materials.The hybridization based on the introduction of low-modulus hydrophobic polypropylene fibers improves the ductility and the strain-hardening behavior of the cementitious composites containing polyvinyl-alcohol fibers of different types(PVA-SHCC).Pull-out tests indicate that adding PP fibers increases the energy capacity of the hybrid composite with respect to the material containing only PVA fibers under tensile loading,and PP-fiber geometry(i.e.,section shape and length)is a key factor in enhancing the strain capacity.