In the background of the construction of Sutong Yangtze River Bridge(short as Sutong Bridge),the cable construction method and techniques of a thousand-meter scale cable-stayed bridge are introduced.Some key construct...In the background of the construction of Sutong Yangtze River Bridge(short as Sutong Bridge),the cable construction method and techniques of a thousand-meter scale cable-stayed bridge are introduced.Some key construction techniques,such as outspreading cable on deck,installing cable at pylon,pulling and fixing cable at the attachment with decks and cable PE sheath protection are discussed.展开更多
The degradation of crosslinked polyethylene (XLPE) cable insulation during service, such as thermo-oxidation and water treeing may lead to a premature electrical breakdown of the XLPE insulation cables. Therefore, it ...The degradation of crosslinked polyethylene (XLPE) cable insulation during service, such as thermo-oxidation and water treeing may lead to a premature electrical breakdown of the XLPE insulation cables. Therefore, it is necessary to optimize the period of replacement to evenly distribute the replacement cost by ascertaining the deterioration degree. Estimation of the aging degree is at present the most important task for diagnosis of the residual lifetime of the power cable insulation. This paper presents a study on the changes in the dielectric properties of the thermally aged XLPE cables in the frequency range from 0.07~10 MHz. Based on electrical and physicochemical characterization, some new "dactylograms" for the thermally aged XLPE cable insulation have been proposed.展开更多
The thick insulation layer of 110 kV XLPE power cables will result in the gradient changing morphology with the radius due to crosslinking process and cooling of the XLPE insulation. In this paper, the morphology of c...The thick insulation layer of 110 kV XLPE power cables will result in the gradient changing morphology with the radius due to crosslinking process and cooling of the XLPE insulation. In this paper, the morphology of cross-linked polyethylene (XLPE) insulation of 110 kV cable and the uniforming effect of the heating process on it are researched by the differential scanning calorimetry (DSC) and X-ray diffraction (WAXD). The middle layer morphology structures of insulation produced by normal technology are of better uniform, while the crystallinity of the inner and outer layer of the insulation is lower than that of the middle one. The melting enthalpy AHm of materials displays the difference of the crystal morphologies sensitively. The difference of crystallizing morphology in different layers of the high-voltage power cable insulation can be improved by heating process. But the uniforming of morphology of the insulation by heating process requires sufficient ttanperature and time. The effect of the on-line stress-relaxation equipment used widely by cable works now should be doubted. The test results of WAXD reveal that thermal stress changes the interplanar distances in the crystal region. So the radical stress in the insulation is tensile mainly.展开更多
The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artifi...The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artificial defect models of cable joints in 10 kV XLPE cable. Oscillating voltage is applied to the model, by use of pulse current method to detect partial discharge signals. In order to study the statistical characteristics of partial discharge of cable joint under the oscillating voltage, three-dimensional statistical map has been made. The results show that for the same kind of defects, with the increases of the defect severity, the discharge interval extended, the magnitude and the number of partial discharge increase, for different kinds of defects, obvious differences exist among the maps, this may established a foundation for the further study of the partial discharge pattern recognition of XLPE cable under oscillating voltage.展开更多
Due to the increasing demand of replacing large capacity overhead lines with underground cables in Korea, KEPCO (Korea Electric Power Corporation) and LS Cable (LS Cable & System) have developed 345 kV optical fi...Due to the increasing demand of replacing large capacity overhead lines with underground cables in Korea, KEPCO (Korea Electric Power Corporation) and LS Cable (LS Cable & System) have developed 345 kV optical fiber composite XLPE (cross-linked polyethylene) 2,500 mm2 cable system. This system has been installed in Cheongna district of Incheon city. KEPCO and LS Cable are also planning to build the cooling system in a tunnel in order to reduce the ambient temperature caused by currents. In this paper, the process of development, field installation, and final inspection test of the complete system will be described.展开更多
基金National Science and Technology Support Program of China(No.2006BAG04B02)
文摘In the background of the construction of Sutong Yangtze River Bridge(short as Sutong Bridge),the cable construction method and techniques of a thousand-meter scale cable-stayed bridge are introduced.Some key construction techniques,such as outspreading cable on deck,installing cable at pylon,pulling and fixing cable at the attachment with decks and cable PE sheath protection are discussed.
基金Major Research Project of Shanghai City(No. 045211024)
文摘The degradation of crosslinked polyethylene (XLPE) cable insulation during service, such as thermo-oxidation and water treeing may lead to a premature electrical breakdown of the XLPE insulation cables. Therefore, it is necessary to optimize the period of replacement to evenly distribute the replacement cost by ascertaining the deterioration degree. Estimation of the aging degree is at present the most important task for diagnosis of the residual lifetime of the power cable insulation. This paper presents a study on the changes in the dielectric properties of the thermally aged XLPE cables in the frequency range from 0.07~10 MHz. Based on electrical and physicochemical characterization, some new "dactylograms" for the thermally aged XLPE cable insulation have been proposed.
文摘The thick insulation layer of 110 kV XLPE power cables will result in the gradient changing morphology with the radius due to crosslinking process and cooling of the XLPE insulation. In this paper, the morphology of cross-linked polyethylene (XLPE) insulation of 110 kV cable and the uniforming effect of the heating process on it are researched by the differential scanning calorimetry (DSC) and X-ray diffraction (WAXD). The middle layer morphology structures of insulation produced by normal technology are of better uniform, while the crystallinity of the inner and outer layer of the insulation is lower than that of the middle one. The melting enthalpy AHm of materials displays the difference of the crystal morphologies sensitively. The difference of crystallizing morphology in different layers of the high-voltage power cable insulation can be improved by heating process. But the uniforming of morphology of the insulation by heating process requires sufficient ttanperature and time. The effect of the on-line stress-relaxation equipment used widely by cable works now should be doubted. The test results of WAXD reveal that thermal stress changes the interplanar distances in the crystal region. So the radical stress in the insulation is tensile mainly.
文摘The oscillating voltage test is a nondestructive detection method for partial discharge of XLPE (cross linked polyethylene) cable and has been applied recently. This paper made three kinds of varying severity artificial defect models of cable joints in 10 kV XLPE cable. Oscillating voltage is applied to the model, by use of pulse current method to detect partial discharge signals. In order to study the statistical characteristics of partial discharge of cable joint under the oscillating voltage, three-dimensional statistical map has been made. The results show that for the same kind of defects, with the increases of the defect severity, the discharge interval extended, the magnitude and the number of partial discharge increase, for different kinds of defects, obvious differences exist among the maps, this may established a foundation for the further study of the partial discharge pattern recognition of XLPE cable under oscillating voltage.
文摘Due to the increasing demand of replacing large capacity overhead lines with underground cables in Korea, KEPCO (Korea Electric Power Corporation) and LS Cable (LS Cable & System) have developed 345 kV optical fiber composite XLPE (cross-linked polyethylene) 2,500 mm2 cable system. This system has been installed in Cheongna district of Incheon city. KEPCO and LS Cable are also planning to build the cooling system in a tunnel in order to reduce the ambient temperature caused by currents. In this paper, the process of development, field installation, and final inspection test of the complete system will be described.