期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
3D打印技术在全肺切除术后的应用 被引量:5
1
作者 李晓军 秦思达 +2 位作者 张佳 张靖 崔晓海 《西安交通大学学报(医学版)》 CAS CSCD 北大核心 2019年第1期126-129,157,共5页
目的探讨3D打印技术在全肺切除术后应用的可行性。方法选用犬作为研究对象,使用3D技术打印出双侧肺模型,外科手术建立左、右全肺切除术的动物模型后,分为对照组及3D打印肺假体植入组;术后观察1年,分别比较左、右肺全切后对照组及假体植... 目的探讨3D打印技术在全肺切除术后应用的可行性。方法选用犬作为研究对象,使用3D技术打印出双侧肺模型,外科手术建立左、右全肺切除术的动物模型后,分为对照组及3D打印肺假体植入组;术后观察1年,分别比较左、右肺全切后对照组及假体植入组早期并发症及远期并发症的发病情况,并对相应组织进行病理学分析,验证假体的组织相容性,并观察有无严重的不良反应。结果在3D打印肺假体移植术后,经过1年的随访,3D打印肺假体植入组实验用犬晚期并发症的发病率较低。CT图像显示,进行对侧肺扩大切除的对照组犬发生了动态纵隔移位。相反地,在3D打印的肺移植个体中,纵隔的位置没有明显的改变。病理结果显示,3D打印的肺并没有引起任何的副作用,显示了受体良好的组织相容性和耐受性。结论 3D打印的肺假体可以安全、有效地移植给受体,有效地治疗因气管缺损或肺缺损导致的疾病,且无显著排斥反应及其他严重副作用。 展开更多
关键词 3D打印 肺假体 移植 切除术
下载PDF
An anthropomorphic phantom study of effect of lung tumor size and location on dosimetric parameters 被引量:2
2
作者 Fuli Zhang Mingmin Zheng Jinbao Zhang Jianping Chen Weidong Xu Junmao Gao 《The Chinese-German Journal of Clinical Oncology》 CAS 2010年第3期133-136,共4页
Objective: The aim of the study was to study the effect of the size and location of tumors on the normal lung dose-volume parameters for lung cancer. Methods: Three spheres with diameters of 2, 3 and 4 cm made of ti... Objective: The aim of the study was to study the effect of the size and location of tumors on the normal lung dose-volume parameters for lung cancer. Methods: Three spheres with diameters of 2, 3 and 4 cm made of tissue-equivalent materials used for simulating tumors were inserted into the upper lobe, middle lobe, lower lobe of the right lung, upper lobe, lower lobe of the left lung of the Rando phantom, respectively. Five-field simplified IMRT (slMRT) planning were designed. The prescribed dose was 60 Gy/2 Gy/30 f, 99% of the planning target volume received this dose. Dose-volume parameters of normal lung tissues including relative volume of lung receiving 〉 5, 10, 20, 30 and 50 Gy (V5, Vl0, V2o, V30, V50), and mean lung dose (MLD) were analyzed and compared. Results: For the dose-volume parameters, the diameter and the position of the tumor had a significant effect (P 〈 0.05). With the diameter expanding from 2 to 3 cm, the parameters associated with tumor lying in various lobes increased by a range between 3.83%-125.38%, while the parameters linked with tumors on different lobes increased by a range between 10.46%-51.46% with the diameter expanding from 3 to 4 cm. Conclusion: Location and size of sphere-like tumor have an obvious effect on dose-volume parameters. Knowing about the degree of influence will help oncologists and physicists better evaluate treatment planning, then the probability of radiation pneumonitis can be reduced. 展开更多
关键词 lung cancer tissue-equivalent material location and size slMRT dosimetric parameter
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部