This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatmen...This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-FF tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes onestep insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepaUc biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy.展开更多
AIM:To determine the incidence and factors responsible for anastomotic leaks and stricture following anterior resection(AR)and its subsequent management.METHODS:Retrospective analysis of data from 108 patients with re...AIM:To determine the incidence and factors responsible for anastomotic leaks and stricture following anterior resection(AR)and its subsequent management.METHODS:Retrospective analysis of data from 108 patients with rectal carcinoma who underwent AR or low anterior resection(LAR)to identify the various preoperative,operative,and post operative factors that might have influence on anastomotic leaks and strictures.RESULTS:There were 68 males and 40 females with an average of 47 years(range 21-75 years).The median distance of the tumor from the anal verge was 8 cm(range 3-15 cm).Sixty(55.6%)patients underwent handsewn anastomosis and 48(44.4%)were stapled.The median operating time was 3.5 h(range2.0-7.5 h).Sixteen(14.6%)patients had an anastomotic leak.Among these,11 patients required reexploration and five were managed expectantly.The anastomotic leak rate was similar in patients with and without diverting stoma(8/60,13.4%with stoma and 8/48;16.7%without stoma).In 15(13.9%)patients,resection margins were positive for malignancy.Ninteen(17.6%)patients developed anastomotic strictures at a median duration of 8 mo(range 3-20 mo).Among these,15 patients were successfully managed with per-anal dilatation.On multivariate analysis,advance age(>60 years)was the only risk factor for anastomotic leak(P=0.004).On the other hand,anastomotic leak(P=0.00),mucin positive tumor(P =0.021),and lower rectal growth(P=0.011)were found as risk factors for the development of an anastomotic stricture.CONCLUSION:Advance age is a risk factor for an anastomotic leak.An anastomotic leak,a mucin-secreting tumor,and lower rectal growth predispose patients to develop anastomotic strictures.展开更多
AIM:To evaluate a new single-operator mini-endoscope, Spyglass,for its performance,feasibility and safety in the management of pancreaticobiliary disease. METHODS:In a multicenter retrospective analysis of patients un...AIM:To evaluate a new single-operator mini-endoscope, Spyglass,for its performance,feasibility and safety in the management of pancreaticobiliary disease. METHODS:In a multicenter retrospective analysis of patients undergoing intraductal endoscopy,we evaluated 128 patients(71 men,mean age 57.6 years).Indications were therapeutic(TX)in 72(56%) and diagnostic(DX)in 56(44%). RESULTS:Peroral endoscopy was performed in 121 and percutaneous in seven.TX indications included CBD stones in 41,PD stones in six,and biliary strictures in 25.DX indications included abnormal LFT’s in 15, abnormal imaging in 38 and cholangiocarcinoma staging in three.Visualization of the stone(s)was considered good in 31,fair in six,and poor in four. Advancement of the electrohydraulic lithotripsy probe was not possible in three patients and proper targeting of the lesion was partial in four patients.A holmium laser was used successfully in three patients.Ductal clearance was achieved in 37 patients after one procedure and in four patients after two procedures.Diagnosis of biliary strictures was modified in 20/29 and confirmed to be malignant in 10/23.Of the modified patients,no diagnosis was available in 17.Spyglass demonstrated malignancy in 8/17 and non-malignancy in nine.Suspected pathology by imaging studies and abnormal LFT’s was modified in 43/63(66%).Staging of cholangiocarcinoma demonstrated multicentric cholangiocarcinoma in 2/3.There was no morbidity associated with the use of Spyglass. CONCLUSION:Spyglass Spyscopeis a first generation, single operator miniature endoscope that can evaluate and treat various biliary and pancreatic tract diseases.展开更多
文摘This report describes a method for percutaneous transhepatic biliary stenting with a BLAKE Silicone Drain, and discusses the usefulness of placement of the drain connected to a J-VAC Suction Reservoir for the treatment of stenotic hepaticojejunostomy. Percutaneous transhepatic biliary drainage was performed under ultrasonographic guidance in a patient with stenotic hepaticojejunostomy after hepatectomy for hepatic hilum malignancy. The technique used was as follows. After dilatation of the drainage root, an 11-FF tube with several side holes was passed through the stenosis of the hepaticojejunostomy. A 10-Fr BLAKE Silicone Drain is flexible, which precludes onestep insertion. One week after insertion of the 11-Fr tube, a 0.035-inch guidewire was inserted into the tube. After removal of the 11-Fr tube, the guidewire was put into the channel of a 10-Fr BLAKE Silicone Drain. The drain was inserted into the jejunal limb through the intrahepatic bile duct and was connected to a J-VAC Suction Reservoir. Low-pressure continued suction was applied. Patients can be discharged after insertion of the 10-Fr BLAKE Silicone Drain connected to the J-VAC Suction Reservoir. Placement of a percutaneous transhepaUc biliary stent using a 10-Fr BLAKE Silicone Drain connected to a J-VAC Suction Reservoir is useful for the treatment of stenotic hepaticojejunostomy.
文摘AIM:To determine the incidence and factors responsible for anastomotic leaks and stricture following anterior resection(AR)and its subsequent management.METHODS:Retrospective analysis of data from 108 patients with rectal carcinoma who underwent AR or low anterior resection(LAR)to identify the various preoperative,operative,and post operative factors that might have influence on anastomotic leaks and strictures.RESULTS:There were 68 males and 40 females with an average of 47 years(range 21-75 years).The median distance of the tumor from the anal verge was 8 cm(range 3-15 cm).Sixty(55.6%)patients underwent handsewn anastomosis and 48(44.4%)were stapled.The median operating time was 3.5 h(range2.0-7.5 h).Sixteen(14.6%)patients had an anastomotic leak.Among these,11 patients required reexploration and five were managed expectantly.The anastomotic leak rate was similar in patients with and without diverting stoma(8/60,13.4%with stoma and 8/48;16.7%without stoma).In 15(13.9%)patients,resection margins were positive for malignancy.Ninteen(17.6%)patients developed anastomotic strictures at a median duration of 8 mo(range 3-20 mo).Among these,15 patients were successfully managed with per-anal dilatation.On multivariate analysis,advance age(>60 years)was the only risk factor for anastomotic leak(P=0.004).On the other hand,anastomotic leak(P=0.00),mucin positive tumor(P =0.021),and lower rectal growth(P=0.011)were found as risk factors for the development of an anastomotic stricture.CONCLUSION:Advance age is a risk factor for an anastomotic leak.An anastomotic leak,a mucin-secreting tumor,and lower rectal growth predispose patients to develop anastomotic strictures.
文摘AIM:To evaluate a new single-operator mini-endoscope, Spyglass,for its performance,feasibility and safety in the management of pancreaticobiliary disease. METHODS:In a multicenter retrospective analysis of patients undergoing intraductal endoscopy,we evaluated 128 patients(71 men,mean age 57.6 years).Indications were therapeutic(TX)in 72(56%) and diagnostic(DX)in 56(44%). RESULTS:Peroral endoscopy was performed in 121 and percutaneous in seven.TX indications included CBD stones in 41,PD stones in six,and biliary strictures in 25.DX indications included abnormal LFT’s in 15, abnormal imaging in 38 and cholangiocarcinoma staging in three.Visualization of the stone(s)was considered good in 31,fair in six,and poor in four. Advancement of the electrohydraulic lithotripsy probe was not possible in three patients and proper targeting of the lesion was partial in four patients.A holmium laser was used successfully in three patients.Ductal clearance was achieved in 37 patients after one procedure and in four patients after two procedures.Diagnosis of biliary strictures was modified in 20/29 and confirmed to be malignant in 10/23.Of the modified patients,no diagnosis was available in 17.Spyglass demonstrated malignancy in 8/17 and non-malignancy in nine.Suspected pathology by imaging studies and abnormal LFT’s was modified in 43/63(66%).Staging of cholangiocarcinoma demonstrated multicentric cholangiocarcinoma in 2/3.There was no morbidity associated with the use of Spyglass. CONCLUSION:Spyglass Spyscopeis a first generation, single operator miniature endoscope that can evaluate and treat various biliary and pancreatic tract diseases.