CT scan is regarded as the imaging modality of choice in patients with pancreaticobiliary ductal abnormalities. However, the axial orientation of the CT images provides only limited anatomical view of pancreaticobilia...CT scan is regarded as the imaging modality of choice in patients with pancreaticobiliary ductal abnormalities. However, the axial orientation of the CT images provides only limited anatomical view of pancreaticobiliary ductal abnormalities. The technological advances of multi-de-tector row CT and three-dimensional image processing in workstations allows rapid image acquisition and a short postprocessing time. In particular, multiplanar reforma-tions (MPR) and minimum intensity projections (MinIP) offer rapid and accurate images of the anatomy and ab-normalities of the pancreaticobiliary tree. Moreover, MPR and MinIP help determine the relationship between the pancreaticobiliary ductal anatomy and the surrounding structures. This pictorial review illustrates the wide spec-trum of images obtained by the MPR and MinIP of the anomalies and disorders of the pancreaticobiliary tree.展开更多
AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallb...AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening.展开更多
Objective: To investigate the clinical significance of magnetic resonance cholangiopancreatography (MRCP) utilizing half-Fourier acquisition single-shot fast spin-echo (HASTE) in the diagnosis of bile duct diseases. M...Objective: To investigate the clinical significance of magnetic resonance cholangiopancreatography (MRCP) utilizing half-Fourier acquisition single-shot fast spin-echo (HASTE) in the diagnosis of bile duct diseases. Methods: Forty-three patients with obstructive jaundice and 4 without were enrolled in this study. The underlying diseases included bile duct calculi ( 13 cases) , chronic cholangitis ( 14 cases) malignant tumors (18 cases) and congenital biliary cysts (2 cases). All patients underwent examinations with magnetic resonance imaging (MRI) and MRCP, and 39 were also examined with B-type ultrasonography, 33 with CT and 25 with ERCP and PTC. Three-dimensional image reconstruction was performed using volume-rendered technique ( VRE) on the basis of the data obtained by MRCP. Results: The biliary calculi were displayed as circular filling defects in MRCP images, with the proximal end of dilated bile duct taking the form of the mouth of a cup. The bile duct of patients with chronic cholangitis showed distal end dilation and thinner proximal end without discontinuity. Interception of the bile ducts was most frequent (72. 2% ) in cases of malignant bile duct obstruction, in which the ducts may also be mastoid or resembling rat tails. 72. 2% of the cases had severe dilation of the bile ducts, which occur in only 16. 0% of the benign cases, with significant difference between them (P <0. 01) . In images of intrahepatic biliary cyst, intrahepatic duct dilated in the shape of a bursa in connection with the duct. By MRCP, 20 malignant obstructions of the bile ducts were identified with 2 misdiagnoses, and in 25 cases of benign obstructions identified by MRCP, only 1 misdiagnoses occurred. Thus MRCP had the sensitivity, specificity and accuracy of 90.0% , 96.3% and 93.6% respectively in discriminating benign and malignant diseases of the bile ducts, showing a total diagnostic accuracy of 94. 0% that was similar to that of ERCP (92.0% ) but significantly higher than those of both CT (75. 0% ) and B-type ultrasonic examination (74. 0% ). Conclusion: In diagnosing obstructive jaundice, HASTE MRCP is similar to ERCP but better than CT and B-type ultrasonography , with the merits of fast imaging and high resolution as an ideal sequence for MRCP imaging.展开更多
文摘CT scan is regarded as the imaging modality of choice in patients with pancreaticobiliary ductal abnormalities. However, the axial orientation of the CT images provides only limited anatomical view of pancreaticobiliary ductal abnormalities. The technological advances of multi-de-tector row CT and three-dimensional image processing in workstations allows rapid image acquisition and a short postprocessing time. In particular, multiplanar reforma-tions (MPR) and minimum intensity projections (MinIP) offer rapid and accurate images of the anatomy and ab-normalities of the pancreaticobiliary tree. Moreover, MPR and MinIP help determine the relationship between the pancreaticobiliary ductal anatomy and the surrounding structures. This pictorial review illustrates the wide spec-trum of images obtained by the MPR and MinIP of the anomalies and disorders of the pancreaticobiliary tree.
文摘AIM: To estimate the detectability of anomalous connection in pancreatobiliary disease (ACPBD) cases, measuring gallbladder wall blood flow (GWBF).METHODS: In the retrospective study, we enrolled 42subjects with gallbladder wall thickening. GWBF velocity was determined as an average value of the peak velocity of color signals on the gallbladder wall, three times in each case. Based on the findings on endoscopic ultrasonography (EUS) or endoscopic retrograde cholangiopancreatography (ERCP), the 42 subjects were divided into 11 cases with ACPBD and 31 cases without ACPBD. In the prospective study, the subjects were 92 cases with gallbladder wall thickening. Using the cut-off level of the flow velocity obtained in the retrospective study, the usefulness of measuring GWBF velocity in diagnosing ACPBD was evaluated.RESULTS: In the retrospective study, imaging of GWBF was obtained in 40 of the 42 subjects. The mean GWBF velocity of the ACPBD cases was 29.4±3.9 cm/s(mean±SD), which was significantly different (P<0.0001;95% CI 5.48-13.2) from that of the without ACPBD cases(20.1±5.9 cm/s). Based on this result, we prepared a receiver operating characteristic curve, and the cut-off level appropriate for diagnosing ACPBD was estimated to be 25 cm/s. In the prospective study, GWBF was detected in 86 of the 92 subjects. Based on the EUS or ERCP findings, the 92 subjects were divided into 15 cases with ACPBD and 77 cases without ACPBD. When a cut-off level of 25 cm/s was employed, ACPBD could be diagnosed with a sensitivity of 87.0% (13/15) and a specificity of87.3% (62/71).CONCLUSION: Measurement of GWBF velocity, which is less invasive and provides objective values, is very useful for diagnosing ACPBD prior to the development of malignant tumors in cases with gallbladder wall thickening.
文摘Objective: To investigate the clinical significance of magnetic resonance cholangiopancreatography (MRCP) utilizing half-Fourier acquisition single-shot fast spin-echo (HASTE) in the diagnosis of bile duct diseases. Methods: Forty-three patients with obstructive jaundice and 4 without were enrolled in this study. The underlying diseases included bile duct calculi ( 13 cases) , chronic cholangitis ( 14 cases) malignant tumors (18 cases) and congenital biliary cysts (2 cases). All patients underwent examinations with magnetic resonance imaging (MRI) and MRCP, and 39 were also examined with B-type ultrasonography, 33 with CT and 25 with ERCP and PTC. Three-dimensional image reconstruction was performed using volume-rendered technique ( VRE) on the basis of the data obtained by MRCP. Results: The biliary calculi were displayed as circular filling defects in MRCP images, with the proximal end of dilated bile duct taking the form of the mouth of a cup. The bile duct of patients with chronic cholangitis showed distal end dilation and thinner proximal end without discontinuity. Interception of the bile ducts was most frequent (72. 2% ) in cases of malignant bile duct obstruction, in which the ducts may also be mastoid or resembling rat tails. 72. 2% of the cases had severe dilation of the bile ducts, which occur in only 16. 0% of the benign cases, with significant difference between them (P <0. 01) . In images of intrahepatic biliary cyst, intrahepatic duct dilated in the shape of a bursa in connection with the duct. By MRCP, 20 malignant obstructions of the bile ducts were identified with 2 misdiagnoses, and in 25 cases of benign obstructions identified by MRCP, only 1 misdiagnoses occurred. Thus MRCP had the sensitivity, specificity and accuracy of 90.0% , 96.3% and 93.6% respectively in discriminating benign and malignant diseases of the bile ducts, showing a total diagnostic accuracy of 94. 0% that was similar to that of ERCP (92.0% ) but significantly higher than those of both CT (75. 0% ) and B-type ultrasonic examination (74. 0% ). Conclusion: In diagnosing obstructive jaundice, HASTE MRCP is similar to ERCP but better than CT and B-type ultrasonography , with the merits of fast imaging and high resolution as an ideal sequence for MRCP imaging.