期刊文献+
共找到25篇文章
< 1 2 >
每页显示 20 50 100
内侧入路钢板内固定治疗胫腓骨骨折28例
1
作者 赵法祥 周枫 张云庆 《右江民族医学院学报》 2003年第6期847-848,共2页
钢板螺钉内固定是常见治疗胫腓骨骨折的手术方法,由于术中一般无需使用C臂机透视及手术牵引床,倍受基层医院骨科医生的青睐.传统的方法是将钢板置于胫骨外侧,因为有较多的肌肉软组织保护可以避免切口感染和裂开后造成的不良后果.近年来... 钢板螺钉内固定是常见治疗胫腓骨骨折的手术方法,由于术中一般无需使用C臂机透视及手术牵引床,倍受基层医院骨科医生的青睐.传统的方法是将钢板置于胫骨外侧,因为有较多的肌肉软组织保护可以避免切口感染和裂开后造成的不良后果.近年来许多学者认为[1~4],钢板置于胫骨内侧更符合生物力学原则,有利于骨折愈合.自1999年5月~2002年5月,我们采用内侧入路钢板螺钉内固定治疗胫腓骨骨折28例,取得良好效果.兹报告如下: 展开更多
关键词 胫骨/骨折 腓骨/骨折 骨折固定术 钢板 内侧入路
下载PDF
A BIOMECHANICAL ANALYSIS OF UNILATERAL HOOKED-SULCATED EXTERNAL FIXATOR ON OSTEOMINED TIBIA
2
作者 段德宇 刘国平 +1 位作者 杜靖远 饶振玉 《Chinese Medical Sciences Journal》 CAS CSCD 1998年第1期49-52,共4页
Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and th... Four tibiae removed from 30-40 years males, who died of accidents in less than 12 hours, were os- teomized at medium part. Then these tibiae were fixed by an unilateral hooked-sulcated external fixator (UHSEF), and the bone-fixator system was used as a model of external fixation of tibial fracture. The axial compression, distraction, torsion, antero-posterior and lateral bending rigidly and the strain of the pins were determined in this system. Based on the results, we found that compared with the configuration of four paralled pins, the rigidity of the fan-like configuraton didn’t decrease significantly if the angle between lateral and medium pins was less than 45’. But the reverse was true when the frame separation increased from 5 to 8 cm. What’ more, the pin strain decreased if the rigidity of the system was improved. These data provided a theoretical basis of biomechanics for the improvement of UHSEF. 展开更多
关键词 TIBIA external fixator biomechanics)
下载PDF
PERCUTANEOUS REDUCTION AND STABILIZATION OF COMPLEX TIBIAL PLATEAU FRACTURES
3
作者 刘国平 杜靖远 《Chinese Medical Sciences Journal》 CAS CSCD 1997年第3期184-188,共5页
Mechanical traction and percutaneous reduction by leverage and fixation by a bilateral groove externalfixator were performed on 23 patients with complex tibial plateau fractures involving a depressed and splitfragment... Mechanical traction and percutaneous reduction by leverage and fixation by a bilateral groove externalfixator were performed on 23 patients with complex tibial plateau fractures involving a depressed and splitfragments. The fixator is composed of two long groove frames, three to five nuts, hooked bolts and Stein-manns pins.All fractures united in good position in three months with no incision (only pinpricks), llttle operativetrauma and no significant complications but pintract infection, and the flexion-extension range of kneemovement was excllent in all patients, so that this technique is particularly advisable for complex tibialplateau fractures. 展开更多
关键词 tibial plateau fracture external fixation
全文增补中
Classification to guide internal fixation for tibial fracture 被引量:5
4
作者 张文玺 郑志良 +1 位作者 吉跃平 乔志军 《Chinese Journal of Traumatology》 CAS 2008年第6期375-379,共5页
Objective: To explore a classification method which can provide the clinical guidance for internal fixation of tibial fracture. Methods: The different fractures were fixed according to their mechanical classificatio... Objective: To explore a classification method which can provide the clinical guidance for internal fixation of tibial fracture. Methods: The different fractures were fixed according to their mechanical classification. Totally, 71 cases of tibial plateau fracture, tibial proximal fracture, tibial distal fracture and Pilon fracture were analyzed to test this selective principle. Results: All 71 patients were followed up for 6-32 months. The displacement was seldomly observed in cases treated acccording to the classification principle, while some cases against the principle had postoperative displacement.The difference was statistically significant (P〈0.05). It was proved that there was remarkable correlation between tibial fracture classification, internal fixator and fixation methods. Conclusion: Types Ⅲa3, Ⅲb 1 and Ⅲb2 fractures without eccentric moment should be fixed with double plates or angle-stable materials combined with locking structure, otherwise displacement may occur. 展开更多
关键词 Tibial fractures Fracture fixation internal CLASSIFICATION
原文传递
Comparative study on treatment of midshaft tibial fracture with expandable and interlocking intramedullary nails 被引量:5
5
作者 毕擎 朱丹杰 +3 位作者 邱斌松 洪剑飞 章水均 夏冰 《Chinese Journal of Traumatology》 CAS 2007年第4期228-232,共5页
Objective : To evaluate the clinical results of treatment of midshaft tibial fracture with expandable intramedullary nails compared with interlocking intramednilary nails. Methods: From June 2003 to August 2005, 46... Objective : To evaluate the clinical results of treatment of midshaft tibial fracture with expandable intramedullary nails compared with interlocking intramednilary nails. Methods: From June 2003 to August 2005, 46 patients (27 males and 19 females, aged 20-74 years, mean =38.4 years ) with midshaft tibial fracture were treated surgically in our department. The causes of fractures were traffic injury in 21 patients, fall injury in 6, tumbling injury in 11 and crushing injury in 8. According to AO/ ASIF classification, Type A fracture was found in 16 patients, Type B in 11, Type C1 in 5, and Type C2 in 2. Open fractures were found in 12 patients, according to Gustilo classification, Type Ⅰ in 9 patients and Type Ⅱin 3 patients. Based on the patients'consent, 24 patients were treated with expandable intramedullary nails (Group A ) and 22 with interlocking intramedullary nails (Group B ). The operation time, blood loss during operation, X-ray fluoroscopic times, hospitalization time, weight bearing time after operation, healing time of fracture and complications of all the patients were recorded. The clinical effects of all the cases were evaluated according to the criteria of Johner-Wruhs. Results: All the patients were followed up for 12,34 months ( mean = 16.2 months). The time of operation, the blood loss, X-ray fluoroscopic times, hospitalization time and healing time of fracture of Group A significantly decreased (P 〈 0.05 ) compared with those of Group B, but the time for weight bearing after operation, the Johner- Wruhs degree of clinical effects and complications had no significant difference between Group A and Group B (P〉0.05). Conclusions: Expandable intramedullary nail can shorten operation time, decrease blood loss and reduce invasion, which is a safe and effective treatment method for tibial midshaft fracture. 展开更多
关键词 Fracture fixation intramedullary Tibial fractures Clinical medicine
原文传递
Orthopaedic surgeon's nightmare: iatrogenic fractures of talus and medial malleolus following tibial nailing 被引量:2
6
作者 Sanjay Meena Vivek Trikha Pramod Saini Rakesh Kumar Buddhadev Chowdhary 《Chinese Journal of Traumatology》 CAS CSCD 2013年第4期243-245,共3页
Intramedullary interlocking nailing is the gold standard for treatment of tibial shaft fractures. The growing use of intramedullary nailing has resulted in an increased number of tibial nailing in daily clinical pract... Intramedullary interlocking nailing is the gold standard for treatment of tibial shaft fractures. The growing use of intramedullary nailing has resulted in an increased number of tibial nailing in daily clinical practice. Despite adequate surgeon experience, tibial nailing is not without complications if proper techniques are not followed. A case of iatrogenic talar neck and medial malleolus frac- tures during intramedullary nailing of tibia in a 24-year-old male is reported. It is believed to be caused by forceful hammering of insertion zig with foot dorsiflexed. To the best of our knowledge, no such case has been reported in the literature. It is possible to reduce the risk of this complication by adoption of preventive measures. 展开更多
关键词 Tibial fracture TALUS Fracture fixation intramedullary
原文传递
Influence of distal tibiofibular synostosis on ankle function 被引量:5
7
作者 侯振海 周继红 +4 位作者 叶虹 施建国 郑隆宝 姚军 倪志明 《Chinese Journal of Traumatology》 CAS 2009年第2期104-106,共3页
Objective: To study the influence of distal tibiofibular synostosis on ankle function. Methods: Prom October 1998 to October 2004, a total of 281 consecutive patients underwent operations because of ankle fractures ... Objective: To study the influence of distal tibiofibular synostosis on ankle function. Methods: Prom October 1998 to October 2004, a total of 281 consecutive patients underwent operations because of ankle fractures or distal fractures of the tibia and fibula. Distal tibiofibular synostosis occurred after operation in 8 patients. The duration of follow-up averaged 20.6 months (14-44 months). The ankle function was assessed on the basis of functional rating system described by Mazur. Results: According to Mazur's ankle evaluation system, 4 patients achieved an excellent result, 2 a good result and 2 a fair result. The dorsiflexion of the synostosis ankle reduced by 8.26 degrees as compared with that of the contralateral ankle, and there was little influence on the plantar flexion. All the patients had a normal gait. Conclusion: The distal tibiofibular synostosis after the operation of ankle fractures or distal fractures of the tibia and fibula usually gives rise to few symptoms and needs no specific treatment. 展开更多
关键词 SYNOSTOSIS ANKLE Fractures bone
原文传递
Triple plating of tibia in a complex bicondylar tibial plateau fracture 被引量:10
8
作者 Atin Jaiswal Naiman Deepak Kachchhap +2 位作者 Yashwant S Tanwar Birendra Kumar Sachin K Yadav 《Chinese Journal of Traumatology》 CAS CSCD 2014年第3期183-186,共4页
High-energy tibial plateau fracture poses a significant challenge and difficulty for orthopaedic surgeons. Fracture of tibial plateau involves major weight bearing joint and may alter knee kinematics. Anatomic reconst... High-energy tibial plateau fracture poses a significant challenge and difficulty for orthopaedic surgeons. Fracture of tibial plateau involves major weight bearing joint and may alter knee kinematics. Anatomic reconstruction of the proximal tibial articular surfaces, restoration of the limb axis (limb alignment) and stable fixation permitting early joint motion are the goals of the treatment. In cases of complex bicondylar tibial plateau fractures, isolated lateral plating is frequently associated with varus malalignment and better results have been obtained with bilateral plating through dual incisions. However sometimes a complex type of bicondylar tibialplateau fractures is encountered in which medial plateau has a biplaner fracture in posterior coronal plane as well as sagittal plane. In such fractures it is imperative to fix the medial plateau with buttressing in both planes. One such fracture pattern of the proximal tibia managed by triple plating through dual posteromedial and anterolateral incisions is discussed in this case report with emphasis on mechanisms of this type of injury, surgical approach and management. 展开更多
关键词 Tibial fractures Bone plates KNEE
原文传递
Octyl-a-cyanoacrylate adhesive in the treatment of tibial transverse fracture in rabbits 被引量:3
9
作者 吕波 屠重琪 +1 位作者 裴福兴 刘雷 《Chinese Journal of Traumatology》 CAS 2005年第4期240-244,共5页
Objective: To observe the effect of octyl-a-cyanoacrylate upon bone healing and its degradation in vitro after middle tibial transverse fracture in rabbits, and to establish treatment of higher efficacy with the appli... Objective: To observe the effect of octyl-a-cyanoacrylate upon bone healing and its degradation in vitro after middle tibial transverse fracture in rabbits, and to establish treatment of higher efficacy with the application of octyl-a-cyanoacrylate.Methods: Middle tibial transverse fracture model of New Zealand rabbits was established. In the experimental group, internal fixation with 2 mm Kirschner wires was performed and the broken ends were fixed with octyl-a-cyanoacrylate. In the control group, only internal fixation with 2 mm Kirschner wires was conducted. Animals were killed at preset time intervals of 2, 4, 6, 8, 10 and 12 weeks postoperatively and samples were harvested.Results: Two weeks after operation, clear fracture lines were observed in both the experimental and the control groups. Fibrous soft tissue connection was noted between the broken ends and there was soft tissue adhesion around the fracture site. There was no callus formation and the broken ends were surrounded by adhesive soft tissues. Obvious external callus formation was confirmed at 8 weeks after operation in both groups with partial disappearance of fracture lines. Ten and twelve weeks after the operation, fracture lines disappeared completely and there was obvious external callus formation and bone union. In the fourth week, fibrous cells and chondrocytes were found to grow into the colloid and surround it at the 6th week. The adhesive material was degraded and gradually absorbed at the 8th week. Chondrification was observed.Conclusions: Two weeks after fixation for tibial fracture in rabbits, octyl-a-cyanoacrylate begins in vivo degradation. Chondrocytes and fibrocytes gradually grow into the degradation area and surround the adhesive material, which broke into pieces at 8 weeks. Complete degradation and disappearance of the adhesive material is present between 10 and12 weeks. No barrier effect hampering fracture healing is noted. 展开更多
关键词 octyl-a-cyanoacrylate FRACTURES fracture healing degradation
原文传递
A two-choice strategy through a medial tibial approach for the treatment of pilon fractures with posterior or anterior fragmentation 被引量:14
10
作者 Luigi Di Giorgio Georgios Touloupakis +1 位作者 Emmanouil Theodorakis Luca Sodano 《Chinese Journal of Traumatology》 CAS CSCD 2013年第5期272-276,共5页
Objective: The anterolateral approach to the tibia has been popularized for the management of tibial pilon fractures. For complex fracture patterns a com- bined anterolateral/anteromedial approach is suitable but a h... Objective: The anterolateral approach to the tibia has been popularized for the management of tibial pilon fractures. For complex fracture patterns a com- bined anterolateral/anteromedial approach is suitable but a high rate of complication has been reported. In our retro- spective study a two-choice strategy adopting a medial tibial approach was proposed for the treatment of pilon fractures with anterior or posterior fragmentation. Methods: Based on an anatomic study oftibial pilon fractures, we retrospectively analyzed the fractures with primary posterior, posterior-lateral or anterior, anterior-lat- eral (Tillaux-Chaput) involvement of the distal tibia. This retrospective study consisted of 18 patients with a closed tibial plafond fracture. The inclusion criteria were: (1) pre- sence of an anterior/anterolateral type fragment or a poste- rior (Volkmann) type fragment involving 〉25% of the articu- lar surface, (2) a minimum follow-up of 12 months, (3) a fibula fracture associated with a medial colunm fracture of the distal tibia, and (4) soft tissue conditions at the time of opera- tion that did not compromise the choice of surgical access (Tscheme classification for closed fractures: grade 0 and grade 1). Tibial plafond fractures were classified into two groups: one presenting anterior and the other with poste- rior rim (Volkmann) fragments. Results: Most patients achieved a good clinical re- covery in terms of range of motion and Olerud-Molander scale scores. Only three patients presented a grade 2 os- teoarthritis at the 12 month follow-up. Conclusion: Our two-choice strategy highlights con- cepts which have been previously debated and described in the literature. But a new extended protocol for surgical approach to the distal tibia, including more fracture pat- terns and their association should be further investigated. 展开更多
关键词 Tibial fractures Fracture fixation Surgical procedures operative Intraoperative complications
原文传递
Hoffa fracture associated with femoral shaft and proxi-mal tibial fractures: report of two cases 被引量:5
11
作者 Anuj Jain Prakash Agrawal +1 位作者 Manish Chadha Amite Pankaj 《Chinese Journal of Traumatology》 CAS 2012年第6期367-369,共3页
Solitary coronal shear fractures of femo- ral condyle, such as Hoffa's fracture, are usually associated with supracondylar or intercondylar fractures of the femur. These fractures are rare and seen in the context of ... Solitary coronal shear fractures of femo- ral condyle, such as Hoffa's fracture, are usually associated with supracondylar or intercondylar fractures of the femur. These fractures are rare and seen in the context of high energy mechanism leading to multiple injuries; therefore a thorough workup of the patient is required to rule out other significant injuries. Hoffa's fracture associated with femo- ral shaft and proximal tibial fractures is extremely rare and no such injury has been reported previously. We report two such cases which were managed with standard operativefixation techniques and demonstrated good to excellent func- tional outcome after a follow-up of one year. This report emphasizes that high index of suspicion is required for di- agnosis of these injuries and a thorough workup is manda- tory to rule out other associated injuries. We also propose a possible mechanism of injury. 展开更多
关键词 Femoral fractures Tibial fractures Fracture fixation
原文传递
Timing of internal fixation and effect on Schatzker IV-VI tibial plateau fractures 被引量:5
12
作者 TANG Xin LIU Lei +6 位作者 TU Chong-qi YANG Tian-fu WANG Guang-lin FANG Yue LI Jian LI Qi PEI Fu-xing 《Chinese Journal of Traumatology》 CAS 2012年第2期81-85,共5页
Objective: To study the effect of internal fixation performed at different times on therapeutic outcomes of Schatzker IV-VI tibial plateau fractureS. Methods: The clinical data of 42 cases ofSehatzker IV- VI tibial... Objective: To study the effect of internal fixation performed at different times on therapeutic outcomes of Schatzker IV-VI tibial plateau fractureS. Methods: The clinical data of 42 cases ofSehatzker IV- VI tibial plateau fractures treated in our department were analyzed retrospectively. Among these 42 patients, 21 re- ceived surgical treatment within 12 h after injury, (Group I), the other 2 [ were first treated by traction or piaster fixation followed by a delayed internal fixation after soft tissue swell- i ing subsided (Group II). The surgical time, comPlications, length of hospital stay, cost of hospitalization, and time for i fracture union, as well as functional recovery were analyzed and compared between the two groups. Results: After 10-28 months follow-up (mean 16.5 months), except 5 cases who lost to follow-upl no differ-ences were found between the two groups regarding surgi- cal time, preoperative and postoperative complications, heal- ing time or the Hospital for Special Surgery (HSS) score at the end of follow-up, but significant differences were found in the length of hospital stay, cost of hospitalization and HSS score at 3 months after operation (P〈0.05). Conclusion: Under certain conditions, early internal fixation for Schatzker IV-VI tibial plateau fracture is feasible, which can shorten the length of hospital stay, decrease the cost of hospitalization and promote early functional rehabilitation. 展开更多
关键词 Tibial fractures Treatment outcome Fracture fixation internal
原文传递
Indirect reduction technique using a distraction support in minimally invasive percutaneous plate osteosynthesis of tibial shaft fractures 被引量:7
13
作者 Wen-Wei Dong Zeng-Yuan Shi +1 位作者 Zheng-Xin Liu Hai-Jiao Mao 《Chinese Journal of Traumatology》 CAS CSCD 2016年第6期348-352,共5页
Purpose: To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Methods: Between March 2011... Purpose: To describe an indirect reduction technique during minimally invasive percutaneous plate osteosynthesis (MIPPO) of tibial shaft fractures with the use of a distraction support. Methods: Between March 2011 and October 2014, 52 patients with a mean age of 48 years (16-72 years) sustaining tibial shaft fractures were included. All the patients underwent MIPPO for the fractures using a distraction support prior to insertion of the plate. Fracture angular deformity was assessed by goniometer measurement on preoperative and postoperative images. Results: Preoperative radiographs revealed a mean of 7.6°(1.2°-28°) angulation in coronal plane and a mean of 6.8°(0.5°-19°) angulation in sagittal plane. Postoperative anteroposterior and lateral radio graphs showed a mean of 0.8°(0°-4.0°) and 0.6°00-3.6°) of varusvalgus and apex anterior/posterior angulation, respectively. No intraoperative or postoperative complications were noted. Conclusions: This study suggests that the distraction support during MIPPO of tibial shaft fractures is an effective and safe method with no associated complications. 展开更多
关键词 Tibial shaft fractures Indirect reduction Distraction supportPercutaneous plating
原文传递
Complications in the management of closed high-energy proximal tibial plateau fractures 被引量:20
14
作者 Kavin Khatri Vijay Sharma +1 位作者 Darsh Goyal Kamran Farooque 《Chinese Journal of Traumatology》 CAS CSCD 2016年第6期342-347,共6页
Purpose: To report complications in the management of complex closed proximal tibial fractures. Method: A retrospective study was conducted to analyze the infectious and noninfectious complications encountered in th... Purpose: To report complications in the management of complex closed proximal tibial fractures. Method: A retrospective study was conducted to analyze the infectious and noninfectious complications encountered in the management of high-energy Schatzker type V and VI tibial plateau fractures. All patients were treated at the level 1 trauma centre between January 20tl and March 2014. Sixty two patients were included in the study. The mean patient age was (43.16 ±11.59) years with 60 males and 2 females. Infectious complications like superficial and deep infection, wound dehiscence, malalignment in the immediate postoperative period and in follow-up period were noted. Results: The overall complication rate was 30.65% (19 out of 62). Infectious complications were noted in 20.97% cases (13162). In majority of the cases (8113), superficial infection was seen which managed with regular dressing and antibiotic administration. The patients (5/13) who had developed deep-seated infection were subjected to repeated debridements, flap coverage, implant removal or amputation depending upon the host response. Thirteen patients had experienced noninfectious complications. Hardware related complications were noticed in six patients and four among them received a secondary procedure. Malalignment was observed in seven patients but only single patient underwent subsequent operative intervention. Conclusion: Proximal tibial plateau fractures especially Shatzker type V and VI are associated with extensive soft tissue damage even in closed injuries. The complications encountered in the management of these fractures can be minimized with appropriate patient selection and minimal soft tissue dissection. 展开更多
关键词 Tibial plateau fractures ComplicationSoft tissue damage
原文传递
aseudoarthrosis of medial tibial plateau fracture role of alignment procedure 被引量:2
15
《Chinese Journal of Traumatology》 CAS CSCD 2013年第2期118-121,共4页
Nonunion in tibial plateau fractures is very rare. Limited literature is available on Pubmed search on intraarticular tibial nonunion. Most of the cases reported have been following failed surgical treatment and none ... Nonunion in tibial plateau fractures is very rare. Limited literature is available on Pubmed search on intraarticular tibial nonunion. Most of the cases reported have been following failed surgical treatment and none was neglected fractures. Three patients of isolated and neglected medial fibial plateau nonunion with almost similar demo- graphic profile are reported in this paper. All the three pa- tients were managed by minimally invasive compressionfixation using lag screws supplemented with limb realign- ment procedure of high tibial osteotomy. We discussed the injury mechanism, management and rehabilitation in such cases and reviewed the available literature regarding such a presentation. 展开更多
关键词 Fracture healing Tibial fractures Frac-ture fixation OSTEOTOMY
原文传递
Internal fixation and bone grafting for intraarticular nonunion of tibial plateau: a report of four cases 被引量:4
16
作者 Ramesh K Sen Ashwani Soni Uttam Chand Saini Daljit Singh 《Chinese Journal of Traumatology》 CAS 2011年第6期371-375,共5页
Intraarticular nonunion of tibial plateau is rare. In the literature, only 9 patients were found to be treated for intraarticular tibial plateau nonunion and they got varying results. Internal fixation along with bone... Intraarticular nonunion of tibial plateau is rare. In the literature, only 9 patients were found to be treated for intraarticular tibial plateau nonunion and they got varying results. Internal fixation along with bone grafting was done as a standard treatment in all cases. We treated 4 different profile cases of intraarticular tibial plateau nonunion in our institution by 4 different methods. We treated these cases with plaster of paris cast, internal fixation along with bone graft, arthrodesis with K-nail and total knee replacement. Case 1 was treated with plaster of paris (POP) cast as the patient refused surgery. The fracture was united and the patient was fully satisfied with full range of motion despite valgus malalignment. Case 2 was managed with open reduction internal fixation along with bone grafting. Thepatient had a good union and got full range of motion at the knee joint. Case 3 was treated with total knee arthroplasty due to her old age and got satisfactory result. Case 4 was an infected nonunion. Arthrodesis was done and the patient could walk with full weight bearing independently. We conclude that internal fixation along with bone grafting may not be suitable in all cases of intraarticular nonunion of tibial plateau. Causes of nonunion, present condition and range of motion of the knee joint, as well as the age of patient should be all considered and the treatment should be individualised according to each patient's situation. 展开更多
关键词 Intra-articular fractures ARTHRODESIS Fracture fixation internal
原文传递
A rare case of bicondylar Hoffa fracture associated with ipsilateral tibial spine avulsion and extensor mechanism disruption 被引量:3
17
作者 Kamal Bali Aditya Krishna Mootha +2 位作者 Vibhu Krishnan Vishal Kumar Saurabh Rawall 《Chinese Journal of Traumatology》 CAS 2011年第4期253-256,共4页
Intra-articular coronal fractures (Hoffas fractures) of distal femur are rare. Although bicondylar involvement in these fractures has been reported in the literature in association with high velocity traumata, the o... Intra-articular coronal fractures (Hoffas fractures) of distal femur are rare. Although bicondylar involvement in these fractures has been reported in the literature in association with high velocity traumata, the occurrence of these fractures involving extensor mechanism rupture and avulsion ofipsilateral tibial spine is extremely rare. To our acquaintance, such a fracture pattern has not yet been reported in the literature so far. In this article, we report one such case and discuss the importance of early diagnosis and prompt internal fixation in the management of such cases.We believe that these rare combinations of injuries should be treated aggressively by early open reduction and anatomic rigid internal fixation in order to achieve good recovery of function. 展开更多
关键词 Femoral fracture TIBIA Fracture fixation internal Knee
原文传递
Comparative prospective study between medial and lateral distal tibial locking compression plates for distal third tibial fractures 被引量:8
18
作者 Sandeep Garg Vikram Khanna +3 位作者 Mahaveer Prashad Goyal Narendra Joshi Amrut Borade Ishan Ghuse 《Chinese Journal of Traumatology》 CAS CSCD 2017年第3期151-154,共4页
Purpose: Tibial fracture is the most common long bone fracture. Distal third tibial fractures are chal- lenging though open reduction and plating can result in anatomical reduction and rigid fixation. This paper aime... Purpose: Tibial fracture is the most common long bone fracture. Distal third tibial fractures are chal- lenging though open reduction and plating can result in anatomical reduction and rigid fixation. This paper aimed to evaluate and compare the results of medial and lateral locking compression plates for distal third tibial fractures. Methods: This prospective clinical study involved 36 patients with distal tibial fractures admitted in Department of Orthopaedics, Sawai Mansingh Medical College & Affiliated Hospital, Jaipur, India, from June 2011 to May 2012, including 29 closed fractures and 7 open fractures at the mean age of 38.9 years. Thirty-six patients were divided equally into two groups based on treatment method, including medial plating group (18 patients) and lateral plating group (18 patients). They were followed up for at least 5 months after discharge. The functional outcomes were evaluated using Tenny and Wiss clinical assess- ment criteria. Results: Malunion was found in 3 cases of medial plating group and in 1 case of lateral plating group. In the medial plating group, there were 5 cases of superficial infections, 1 deep infection, 1 nonunion and 3 wound dehiscence. In the lateral plating group, there was 1 case of superficial infections, 1 deep infection and 1 nonunion, in the lateral plating group, 4 patients reported feeling the plates and screws but none of them asked to remove the hardware. In the medial plating group, 9 patients reported symptomatic hardware problems and 7 asked to remove the hardware. The number of cases graded as excellent/good/ fair was 1/8/7 in the medial plating group and 3/7/7 in the lateral plating group respectively. In the medial plating group, the final range of motion was 17.2° in ankle dorsiflexion and 30.7° in ankle plantar flexion. In the lateral plating group, the final range of motion was 19° in ankle dorsiflexion and 34.2° in ankle plantar flexion. Conclusion: Lateral plating of distal tibia is safe and feasible, which can provide biological fixation and prevent the soft tissue complications associated with medial plating. 展开更多
关键词 Tibial fractures Bone plates Open fracture reduction
原文传递
Distal tibial fracture: An ideal indication for external fixation using locking plate 被引量:10
19
作者 Jing-wei Zhang Nabil A. Ebraheim +4 位作者 Ming Li Xian-Feng He Joshua Schwind Li-Mei Zhu Yi-Hui Yu 《Chinese Journal of Traumatology》 CAS CSCD 2016年第2期104-108,共5页
Objective: To evaluate the feasibility and efficiency of one-stage external fixation by using locking plate in distal tibial fractures. Methods: In this non-control prospective study, 28 patients with distal tibial ... Objective: To evaluate the feasibility and efficiency of one-stage external fixation by using locking plate in distal tibial fractures. Methods: In this non-control prospective study, 28 patients with distal tibial fractures were included and underwent one-stage external fixation by using locking plate. There were 21 males and 7 females, with a mean age of 43 years (19-63). According to AO/OTA fracture classification, there were 9 cases of Type A1, 9 of Type A2, 10 of Type A3 fractures. There were 21 close and 7 open fractures. The locking plate was placed on the anteromedial aspect of the tibia with 4-5 bicortical screws inserted in both distal metaphysis and diaphysis. The radiographic and clinic results were evaluated. Results: All patients were followed up for the average of 16 months (ranging from 12 to 21 months). The average surgery duration was 38 (25-60) minutes. The mean time to fracture healing were 14.6 ± 2.67, 17.5 ± 3.66, and 18.4±3.37 (p 〈 0.05) weeks in type A1, A2, and A3 fractures respectively. By the end of the follow-ups, the mean AOFAS score were 96.11 ± 2.32, 92.67 ± 1.80 and 92.00± 2.06 (p 〉 0.05) in type A1, A2, and A3 fractures respectively. None of nonunion, deep infection, or breakage of screw or plate were observed. Conclusions: Distal tibial fracture was the ideal indication for external fixation using locking plate. The external plating is characterized by ease of performance, less invasive, fewer soft tissue impingement, improved cosmesis, and convenient for removal. 展开更多
关键词 Tibia fractureSurgeryExternal fixationLocking plate
原文传递
Experiences and lessons about soft-tissue flaps covering of severe open tibial fracture
20
作者 侯之启 徐中和 苏增贵 《Chinese Journal of Traumatology》 CAS 2001年第4期245-247,共3页
Objective: To sum up experiences and lessons about management of soft-tissue reconstruction in open tibial fracture over a 6-year period. Methods: Twenty-two flap reconstructions were performed to treat soft-tissue de... Objective: To sum up experiences and lessons about management of soft-tissue reconstruction in open tibial fracture over a 6-year period. Methods: Twenty-two flap reconstructions were performed to treat soft-tissue defect of 22 patients with open tibial fracture Type IIIB (Gustilo) from 1993 to 1998. The cases were analyzed and discussed retrospectively after follow up of 12-61 months. Results: The size of the flap ranged from 6.6 cm 2 to 28.18 cm 2 and the rate of flap failure was 13.6%. Besides, 3 partial necrosis and 2 postoperative infections occurred in this series. Conclusions: For soft tissue defect of delayed open tibial fracture Type IIIB, flap reconstruction is still an optimal option. The experiences we obtained are ① to design a triangular skin extension or a small Z-plasty over the pedicle to reduce the flap tension; ② to select a unilateral external fixation to provide convenience for any secondary manipulation; and ③ to use serial debridement to diminish flap failure. 展开更多
关键词 TIBIA Fractures open Flap reconstruction
原文传递
上一页 1 2 下一页 到第
使用帮助 返回顶部