We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractiv...We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong.展开更多
AIM:To compare the diagnostic yield of capsule endoscopy (CE) with that of double-balloon enteroscopy (DBE). METHODS:Pubmed,Embase,Elsevier ScienceDirect,the China Academic Journals Full-text Database,and Cochrane Con...AIM:To compare the diagnostic yield of capsule endoscopy (CE) with that of double-balloon enteroscopy (DBE). METHODS:Pubmed,Embase,Elsevier ScienceDirect,the China Academic Journals Full-text Database,and Cochrane Controlled Trials Register were searched for the trials comparing the yield of CE with that of DBE. Outcome measure was odds ratio (OR) of the yield. Fixed or random model method was used for data analysis. RESULTS:Eight studies (n = 277) which prospectively compared the yield of CE and DBE were collected. The results of meta-analysis indicated that there was no difference between the yield of CE and DBE 170/277 vs 156/277,OR 1.21 (95% CI:0.64-2.29). Based on sub analysis,the yield of CE was significantly higher than that of double-balloon enteroscopy without combination of oral and anal insertion approaches 137/219 vs 110/219,OR 1.67 (95% CI:1.14-2.44),P < 0.01),but not superior to the yield of DBE with combination of the two insertion approaches 26/48 vs 37/48,OR 0.33 (95% CI:0.05-2.21),P > 0.05). A focused meta-analysis of the fully published articles concerning obscure GI bleeding was also performed and showed similar results wherein the yield of CE was significantly higher than that of DBE without combination of oral and anal insertion approaches 118/191 vs 96/191,fixed model:OR 1.61 (95% CI:1.07-2.43),P < 0.05) and the yield of CE was significantly lower than that of DBE by oral and anal combinatory approaches 11/24 vs 21/24,fixed model:OR 0.12 (95% CI:0.03-0.52),P < 0.01). CONCLUSION:With combination of oral and anal approaches,the yield of DBE might be at least as high asthat of CE. Decisions made regarding the initial approach should depend on patient's physical status,technology availability,patient's preferences,and potential for therapeutic endoscopy.展开更多
Until recently, diagnosis and management of small-bowel tumors were delayed by the diffi culty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new ...Until recently, diagnosis and management of small-bowel tumors were delayed by the diffi culty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High- quality images of the small-bowel mucosa may be captured and small and ? at lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion’s endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push- and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings,remains to be determined through carefully-designed studies.展开更多
Obscure gastrointestinal bleeding (OGIB) is defi ned as bleeding of an unknown origin that persists or recurs after negative initial upper and lower endoscopies. Several techniques, such as endoscopy, arteriography, s...Obscure gastrointestinal bleeding (OGIB) is defi ned as bleeding of an unknown origin that persists or recurs after negative initial upper and lower endoscopies. Several techniques, such as endoscopy, arteriography, scintigraphy and barium radiology are helpful for recognizing the bleeding source; nevertheless, in about 5%-10% of cases the bleeding lesion cannot be determined. The development of videocapsule endoscopy (VCE) has permitted a direct visualization of the small intestine mucosa. We will analyze those techniques in more detail. The diagnostic yield of CE for OGIB varies from 38% to 93%, being in the higher range in those cases with obscure-overt bleeding.展开更多
AIM: To determine the effect of oral erythromycin on gastric and small bowel transit time of capsule endoscopy. METHODS: Consecutive patients who underwent capsule endoscopy during the 16-mo study period were either...AIM: To determine the effect of oral erythromycin on gastric and small bowel transit time of capsule endoscopy. METHODS: Consecutive patients who underwent capsule endoscopy during the 16-mo study period were either given 250 mg oral erythromycin, 1 h prior to swallowing the capsule endoscope or nothing. The gastric and small bowel transit time, and the small bowel image quality were compared. RESULTS: Twenty-four patients received oral erythromycin whereas 14 patients were not given any prokinetic agent. Patients who received erythromycin had a significantly lower gastric transit time than control (16 min vs70 min, P= 0.005), whereas the small bowel transit time was comparable between the two groups (227 rain vs 183 min, P= 0.18). Incomplete small bowel examination was found in three patients of the control group and in one patient of the erythromycin group. There was no significant difference in the overall quality of small bowel images between the two groups. A marked reduction in gastric transit time was noted in two patients who had repeat capsule endoscopy after oral erythromycin. CONCLUSION: Use of oral erythromycin significantly reduces the gastric transit time of capsule endoscopy.展开更多
AIM:Capsule endoscopy has demonstrated its clinical utility in the evaluation of small bowel pathology in several Western studies.In this prospective study,we aimed to determine the clinical utility,safety and tolerab...AIM:Capsule endoscopy has demonstrated its clinical utility in the evaluation of small bowel pathology in several Western studies.In this prospective study,we aimed to determine the clinical utility,safety and tolerability of capsule endoscopy in the evaluation of suspected small bowel disease in an urban Southeast Asian population. METHODS:We used the given (M2A) capsule endoscopy system in 16 consecutive patients with suspected small bowel pathology.In 9 patients the indication was obscure gastrointestinal bleeding,while in 6 patients it was to determine the extent of small bowel involvement in Crohn's disease.One patient underwent capsule endoscopy for evaluation of chronic abdominal pain.Patient's tolerability to the procedure was evaluated by standardized questionnaires and all patients were reviewed at one week to ensure that the capsule had been excreted without any adverse events. RESULTS:Abnormal findings were present in 8 patients (50%).The cause of obscure gastrointestinal bleeding was determined in 5 out of 9 patients.Findings included 2 cases of angiodysplasia,2 cases of jejunal ulcers and 1 case of both angiodysplasia and jejunal ulcer.One patient had small bowel erosions and loci of erythema of doubtful significance. Ileal lesions were diagnosed in 2 out of 6 patients with Crohn's disease.Capsule endoscopy was well tolerated by all patients.One patient with Crohn's disease had a complication of capsule retention due to terminal ileum stricture.The capsule eventually passed out spontaneously after i month. CONCLUSION:Our study,which represented the first Asian series,further confirms the diagnostic utility,safety and tolerability of wireless capsule endoscopy.展开更多
Wireless capsule endoscopy is a new technique that allows complete exploration of the small bowel without exlemal wires. Its role has been analyzed in many small bowel diseases such as obscure gastrointestinal bleedin...Wireless capsule endoscopy is a new technique that allows complete exploration of the small bowel without exlemal wires. Its role has been analyzed in many small bowel diseases such as obscure gastrointestinal bleeding, Crohn's disease and gastrointestinal polyposis syndromes with promising results. Studies on other pathologies (i.e. small bowel tumour, celiac disease) are under evaluation to define the role of this technique.展开更多
Video capsule endoscopy is an attractive and patient- friendly tool that provides high quality images of the small bowel. Obscure gastrointestinal bleeding is the primary and most evaluated indication to capsule endos...Video capsule endoscopy is an attractive and patient- friendly tool that provides high quality images of the small bowel. Obscure gastrointestinal bleeding is the primary and most evaluated indication to capsule endoscopy;however,indications are expanding and a small number of preliminary reports have been presented concerning the role of video capsule endoscopy in the diagnosis of celiac disease. The purpose of this review is to update the current knowledge and to hypothesize on future perspectives of the use of video capsule endoscopy in patients with celiac disease.展开更多
Capsule endoscopy has been shown to detect small bowel inflammatory changes better than any other imaging modality. Selection criteria have been optimized to increase the yield of capsule endoscopy in patients suspect...Capsule endoscopy has been shown to detect small bowel inflammatory changes better than any other imaging modality. Selection criteria have been optimized to increase the yield of capsule endoscopy in patients suspected to have Crohn's disease. Capsule endoscopy allows for earlier diagnosis of Crohn's disease of the small bowel and improved diagnosis of colitis in patients where it is unclear if they suffer from Crohn's or ulcerative colitis. A test capsule is available to assess for small bowel strictures and thus avoid capsule retention. A common language has been developed and a new scoring index will be added to capsule software. It is envisioned that the manner in which we treat Crohn's disease in the future will change, based on earlier diagnosis and treatment aimed at mucosal healing rather than symptom improvement.展开更多
AIM: To determine the effect of Prepacol, a combination of sodium phosphate and bisacodyl, on transit and quality of capsule endoscopy (CE). METHODS: Fivety two consecutive patients were included in this prospecti...AIM: To determine the effect of Prepacol, a combination of sodium phosphate and bisacodyl, on transit and quality of capsule endoscopy (CE). METHODS: Fivety two consecutive patients were included in this prospective study. CE was performed following a 12 h fasting period. Twenty six patients were randomized for additional preparation with Prepacol. The quality of CE was assessed separately for the proximal and the distal small bowel by 3 experienced endoscopists on the basis of a graduation which was initially developed with 20 previous CE. RESULTS: Preparation with Prepacol accelerated small bowel transit time (262 ± 55 rain vs 287 ± 97 min), but had no effect on the quality of CE. Visibility was significantly reduced in the distal compared to the proximal small bowel. CONCLUSION: The significantly reduced visibility of CE in the distal small bowel allocates the need for a good preparation. Since Prepacol has no beneficial effect on CE the modality of preparation and the ideal time of application remains unclear. Further standardized examinations are necessary to identify sufficient preparation procedures and to determine the impact of the volume of the preparation solution.展开更多
Wireless capsule endoscope (WCE) for the investigation of the small bowel is an approved technique both in adults and children (more than 10 years old). The present review provides data on the indications, diagnostic ...Wireless capsule endoscope (WCE) for the investigation of the small bowel is an approved technique both in adults and children (more than 10 years old). The present review provides data on the indications, diagnostic yield, adverse events and limitations of the WCE technique in children and tries to predict the future of WCE usage in this population of patients.展开更多
Despite significant advances over the last decade, mucosal lesions of the small bowel are poorly detected by imaging studies such as CT scan, MRI-enteroclysis and contrast-enhanced abdominal ultrasound. Capsule endosc...Despite significant advances over the last decade, mucosal lesions of the small bowel are poorly detected by imaging studies such as CT scan, MRI-enteroclysis and contrast-enhanced abdominal ultrasound. Capsule endoscopy (CE) has dramatically changed the diagnostic approach to intestinal diseases. Moreover, the use of CE can be extended to include other conditions. However, it is diffi cult to assess the positive influence of CE on patient outcomes in conditions involving a small number of patients, or in critically ill and diff icult to examine patients. CE has the advantage of diagnosing intestinal lesions and of directing the use of double balloon enteroscopy (DBE) in order to obtain biopsy specimens. Moreover, CE allows repeated assessment in chronic conditions, especially to detect relapse of an infectious disease.展开更多
In order to have an adequate view of the whole small intestine during capsule endoscopy, the preparation recommended consists of a clear liquid diet and an overnight fast. However, visualization of the small bowel dur...In order to have an adequate view of the whole small intestine during capsule endoscopy, the preparation recommended consists of a clear liquid diet and an overnight fast. However, visualization of the small bowel during video capsule endoscopy can be impaired by intestinal contents. To improve mucosal visualization, some authors have evaluated different regimens of preparation. There is no consensus about the necessity of intestinal preparation for capsule endoscopy and it should be interesting to develop adequate guidelines to improve its efficacy and tolerability. Moreover, the effect of preparation type (purgative) on intestinal transit time is not clear. Since a bowel preparation cannot defini-tively improve its visibility (and theoretically the yield of the test), it is not routinely recommended.展开更多
Wireless capsule endoscopy has become the first imaging tool for small bowel examination. Recently, new capsule endoscopy applications have been developed, such as esophageal capsule endoscopy and colon capsule endosc...Wireless capsule endoscopy has become the first imaging tool for small bowel examination. Recently, new capsule endoscopy applications have been developed, such as esophageal capsule endoscopy and colon capsule endoscopy. Clinical trials results have shown that colon capsule endoscopy is feasible, accurate and safe in patients suffering from colonic diseases. It could be a good alternative in patients refusing conventional colonoscopy or when it is contraindicated. Upcoming studies are needed to demonstrate its utility for colon cancer screening and other indications such us ulcerative colitis. Comparative studies including both conventional and virtual colonoscopy are also required.展开更多
Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasi...Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture.展开更多
文摘We outline probable and possible developments with wireless capsule endoscopy. It seems likely that capsule endoscopy will become increasingly effective in diagnostic gastrointestinal endoscopy. This will be attractive to patients especially for cancer or varices detection because capsule endoscopy is painless and is likely to have a higher take up rate compared to conventional colonoscopy and gastroscopy. Double imager capsules with increased frame rates have been used to image the esophagus for Barrett's and esophageal varices. The image quality is not bad but needs to be improved if it is to become a realistic substitute for flexible upper and lower gastrointestinal endoscopy. An increase in the frame rate, angle of view, depth of field, image numbers, duration of the procedure and improvements in illumination seem likely. Colonic, esophageal and gastric capsules will improve in quality, eroding the supremacy of flexible endoscopy, and become embedded into screening programs. Therapeutic capsules will emerge with brushing, cytology, fluid aspiration, biopsy and drug delivery capabilities. Electrocautery may also become possible. Diagnostic capsules will integrate physiological measurements with imaging and optical biopsy, and immunologic cancer recognition. Remote control movement will improve with the use of magnets and/or electrostimulation and perhaps electromechanical methods. External wireless commands will influence capsule diagnosis and therapy and will increasingly entail the use of real-time imaging. However, it should be noted that speculations about the future of technology in any detail are almost always wrong.
文摘AIM:To compare the diagnostic yield of capsule endoscopy (CE) with that of double-balloon enteroscopy (DBE). METHODS:Pubmed,Embase,Elsevier ScienceDirect,the China Academic Journals Full-text Database,and Cochrane Controlled Trials Register were searched for the trials comparing the yield of CE with that of DBE. Outcome measure was odds ratio (OR) of the yield. Fixed or random model method was used for data analysis. RESULTS:Eight studies (n = 277) which prospectively compared the yield of CE and DBE were collected. The results of meta-analysis indicated that there was no difference between the yield of CE and DBE 170/277 vs 156/277,OR 1.21 (95% CI:0.64-2.29). Based on sub analysis,the yield of CE was significantly higher than that of double-balloon enteroscopy without combination of oral and anal insertion approaches 137/219 vs 110/219,OR 1.67 (95% CI:1.14-2.44),P < 0.01),but not superior to the yield of DBE with combination of the two insertion approaches 26/48 vs 37/48,OR 0.33 (95% CI:0.05-2.21),P > 0.05). A focused meta-analysis of the fully published articles concerning obscure GI bleeding was also performed and showed similar results wherein the yield of CE was significantly higher than that of DBE without combination of oral and anal insertion approaches 118/191 vs 96/191,fixed model:OR 1.61 (95% CI:1.07-2.43),P < 0.05) and the yield of CE was significantly lower than that of DBE by oral and anal combinatory approaches 11/24 vs 21/24,fixed model:OR 0.12 (95% CI:0.03-0.52),P < 0.01). CONCLUSION:With combination of oral and anal approaches,the yield of DBE might be at least as high asthat of CE. Decisions made regarding the initial approach should depend on patient's physical status,technology availability,patient's preferences,and potential for therapeutic endoscopy.
文摘Until recently, diagnosis and management of small-bowel tumors were delayed by the diffi culty of access to the small bowel and the poor diagnostic capabilities of the available diagnostic techniques. An array of new methods has recently been developed, increasing the possibility of detecting these tumors at an earlier stage. Capsule endoscopy (CE) appears to be an ideal tool to recognize the presence of neoplastic lesions along this organ, since it is non-invasive and enables the entire small bowel to be visualized. High- quality images of the small-bowel mucosa may be captured and small and ? at lesions recognized, without exposure to radiation. Recent studies on a large population of patients undergoing CE have reported small-bowel tumor frequency only slightly above that reported in previous surgical series (range, 1.6%-2.4%) and have also confirmed that the main clinical indication to CE in patients with small-bowel tumors is obscure gastrointestinal (GI) bleeding. The majority of tumors identified by CE are malignant; many were unsuspected and not found by other methods. However, it remains difficult to identify pathology and tumor type based on the lesion’s endoscopic appearance. Despite its limitations, CE provides crucial information leading in most cases to changes in subsequent patient management. Whether the use of CE in combination with other new diagnostic (MRI or multidetector CT enterography) and therapeutic (Push- and-pull enteroscopy) techniques will lead to earlier diagnosis and treatment of these neoplasms, ultimately resulting in a survival advantage and in cost savings,remains to be determined through carefully-designed studies.
文摘Obscure gastrointestinal bleeding (OGIB) is defi ned as bleeding of an unknown origin that persists or recurs after negative initial upper and lower endoscopies. Several techniques, such as endoscopy, arteriography, scintigraphy and barium radiology are helpful for recognizing the bleeding source; nevertheless, in about 5%-10% of cases the bleeding lesion cannot be determined. The development of videocapsule endoscopy (VCE) has permitted a direct visualization of the small intestine mucosa. We will analyze those techniques in more detail. The diagnostic yield of CE for OGIB varies from 38% to 93%, being in the higher range in those cases with obscure-overt bleeding.
文摘AIM: To determine the effect of oral erythromycin on gastric and small bowel transit time of capsule endoscopy. METHODS: Consecutive patients who underwent capsule endoscopy during the 16-mo study period were either given 250 mg oral erythromycin, 1 h prior to swallowing the capsule endoscope or nothing. The gastric and small bowel transit time, and the small bowel image quality were compared. RESULTS: Twenty-four patients received oral erythromycin whereas 14 patients were not given any prokinetic agent. Patients who received erythromycin had a significantly lower gastric transit time than control (16 min vs70 min, P= 0.005), whereas the small bowel transit time was comparable between the two groups (227 rain vs 183 min, P= 0.18). Incomplete small bowel examination was found in three patients of the control group and in one patient of the erythromycin group. There was no significant difference in the overall quality of small bowel images between the two groups. A marked reduction in gastric transit time was noted in two patients who had repeat capsule endoscopy after oral erythromycin. CONCLUSION: Use of oral erythromycin significantly reduces the gastric transit time of capsule endoscopy.
文摘AIM:Capsule endoscopy has demonstrated its clinical utility in the evaluation of small bowel pathology in several Western studies.In this prospective study,we aimed to determine the clinical utility,safety and tolerability of capsule endoscopy in the evaluation of suspected small bowel disease in an urban Southeast Asian population. METHODS:We used the given (M2A) capsule endoscopy system in 16 consecutive patients with suspected small bowel pathology.In 9 patients the indication was obscure gastrointestinal bleeding,while in 6 patients it was to determine the extent of small bowel involvement in Crohn's disease.One patient underwent capsule endoscopy for evaluation of chronic abdominal pain.Patient's tolerability to the procedure was evaluated by standardized questionnaires and all patients were reviewed at one week to ensure that the capsule had been excreted without any adverse events. RESULTS:Abnormal findings were present in 8 patients (50%).The cause of obscure gastrointestinal bleeding was determined in 5 out of 9 patients.Findings included 2 cases of angiodysplasia,2 cases of jejunal ulcers and 1 case of both angiodysplasia and jejunal ulcer.One patient had small bowel erosions and loci of erythema of doubtful significance. Ileal lesions were diagnosed in 2 out of 6 patients with Crohn's disease.Capsule endoscopy was well tolerated by all patients.One patient with Crohn's disease had a complication of capsule retention due to terminal ileum stricture.The capsule eventually passed out spontaneously after i month. CONCLUSION:Our study,which represented the first Asian series,further confirms the diagnostic utility,safety and tolerability of wireless capsule endoscopy.
文摘Wireless capsule endoscopy is a new technique that allows complete exploration of the small bowel without exlemal wires. Its role has been analyzed in many small bowel diseases such as obscure gastrointestinal bleeding, Crohn's disease and gastrointestinal polyposis syndromes with promising results. Studies on other pathologies (i.e. small bowel tumour, celiac disease) are under evaluation to define the role of this technique.
文摘Video capsule endoscopy is an attractive and patient- friendly tool that provides high quality images of the small bowel. Obscure gastrointestinal bleeding is the primary and most evaluated indication to capsule endoscopy;however,indications are expanding and a small number of preliminary reports have been presented concerning the role of video capsule endoscopy in the diagnosis of celiac disease. The purpose of this review is to update the current knowledge and to hypothesize on future perspectives of the use of video capsule endoscopy in patients with celiac disease.
文摘Capsule endoscopy has been shown to detect small bowel inflammatory changes better than any other imaging modality. Selection criteria have been optimized to increase the yield of capsule endoscopy in patients suspected to have Crohn's disease. Capsule endoscopy allows for earlier diagnosis of Crohn's disease of the small bowel and improved diagnosis of colitis in patients where it is unclear if they suffer from Crohn's or ulcerative colitis. A test capsule is available to assess for small bowel strictures and thus avoid capsule retention. A common language has been developed and a new scoring index will be added to capsule software. It is envisioned that the manner in which we treat Crohn's disease in the future will change, based on earlier diagnosis and treatment aimed at mucosal healing rather than symptom improvement.
文摘AIM: To determine the effect of Prepacol, a combination of sodium phosphate and bisacodyl, on transit and quality of capsule endoscopy (CE). METHODS: Fivety two consecutive patients were included in this prospective study. CE was performed following a 12 h fasting period. Twenty six patients were randomized for additional preparation with Prepacol. The quality of CE was assessed separately for the proximal and the distal small bowel by 3 experienced endoscopists on the basis of a graduation which was initially developed with 20 previous CE. RESULTS: Preparation with Prepacol accelerated small bowel transit time (262 ± 55 rain vs 287 ± 97 min), but had no effect on the quality of CE. Visibility was significantly reduced in the distal compared to the proximal small bowel. CONCLUSION: The significantly reduced visibility of CE in the distal small bowel allocates the need for a good preparation. Since Prepacol has no beneficial effect on CE the modality of preparation and the ideal time of application remains unclear. Further standardized examinations are necessary to identify sufficient preparation procedures and to determine the impact of the volume of the preparation solution.
文摘Wireless capsule endoscope (WCE) for the investigation of the small bowel is an approved technique both in adults and children (more than 10 years old). The present review provides data on the indications, diagnostic yield, adverse events and limitations of the WCE technique in children and tries to predict the future of WCE usage in this population of patients.
文摘Despite significant advances over the last decade, mucosal lesions of the small bowel are poorly detected by imaging studies such as CT scan, MRI-enteroclysis and contrast-enhanced abdominal ultrasound. Capsule endoscopy (CE) has dramatically changed the diagnostic approach to intestinal diseases. Moreover, the use of CE can be extended to include other conditions. However, it is diffi cult to assess the positive influence of CE on patient outcomes in conditions involving a small number of patients, or in critically ill and diff icult to examine patients. CE has the advantage of diagnosing intestinal lesions and of directing the use of double balloon enteroscopy (DBE) in order to obtain biopsy specimens. Moreover, CE allows repeated assessment in chronic conditions, especially to detect relapse of an infectious disease.
文摘In order to have an adequate view of the whole small intestine during capsule endoscopy, the preparation recommended consists of a clear liquid diet and an overnight fast. However, visualization of the small bowel during video capsule endoscopy can be impaired by intestinal contents. To improve mucosal visualization, some authors have evaluated different regimens of preparation. There is no consensus about the necessity of intestinal preparation for capsule endoscopy and it should be interesting to develop adequate guidelines to improve its efficacy and tolerability. Moreover, the effect of preparation type (purgative) on intestinal transit time is not clear. Since a bowel preparation cannot defini-tively improve its visibility (and theoretically the yield of the test), it is not routinely recommended.
文摘Wireless capsule endoscopy has become the first imaging tool for small bowel examination. Recently, new capsule endoscopy applications have been developed, such as esophageal capsule endoscopy and colon capsule endoscopy. Clinical trials results have shown that colon capsule endoscopy is feasible, accurate and safe in patients suffering from colonic diseases. It could be a good alternative in patients refusing conventional colonoscopy or when it is contraindicated. Upcoming studies are needed to demonstrate its utility for colon cancer screening and other indications such us ulcerative colitis. Comparative studies including both conventional and virtual colonoscopy are also required.
文摘Small bowel strictures can be missed by current diagnostic methods. The Patency capsule is a new non-endoscopic dissolvable capsule which has as an objective of checking the patency of digestive tract, in a non-invasive manner. The available clinical trials have demonstrated that the Patency capsule is a good tool for assessment of the functional patency of the small bowel, and it allows identification of those patients who can safely undergo a capsule endoscopy, despite clinical and radiographic evidence of small-bowel obstruction. Some cases of intestinal occlusion have been reported with the Patency capsule, four of them needed surgery. So, a new capsule with two timer plugs (Agile capsule) has been recently developed in order to minimize the risk of occlusion. This new device stars its dissolution process earlier (30 h after ingestion) and its two timer plugs have been designed to begin the disintegration even when the device is blocked in a tight stricture.