To reduce energy consumption in cloud data centres,in this paper,we propose two algorithms called the Energy-aware Scheduling algorithm using Workload-aware Consolidation Technique(ESWCT) and the Energyaware Live Migr...To reduce energy consumption in cloud data centres,in this paper,we propose two algorithms called the Energy-aware Scheduling algorithm using Workload-aware Consolidation Technique(ESWCT) and the Energyaware Live Migration algorithm using Workload-aware Consolidation Technique(ELMWCT).As opposed to traditional energy-aware scheduling algorithms,which often focus on only one-dimensional resource,the two algorithms are based on the fact that multiple resources(such as CPU,memory and network bandwidth)are shared by users concurrently in cloud data centres and heterogeneous workloads have different resource consumption characteristics.Both algorithms investigate the problem of consolidating heterogeneous workloads.They try to execute all Virtual Machines(VMs) with the minimum amount of Physical Machines(PMs),and then power off unused physical servers to reduce power consumption.Simulation results show that both algorithms efficiently utilise the resources in cloud data centres,and the multidimensional resources have good balanced utilizations,which demonstrate their promising energy saving capability.展开更多
The objective of this research is to quantify the EEC (embodied energy/CO2) of a building. The EEC represents the energy consumption and CO2 emissions at individual phases of a building's life-cycle, such as constr...The objective of this research is to quantify the EEC (embodied energy/CO2) of a building. The EEC represents the energy consumption and CO2 emissions at individual phases of a building's life-cycle, such as construction (including manufacture of materials and equipment), renewal (including repair work) and demolition. Energy and CO2 emission intensities in terms of 401 sectors were calculated, using the 2005 I-O (input-output) table in Japan. According to our case study conducted from the construction phase to demolition, the EC (embodied CO2) of an office building used for 60 years is 12,044 t-CO2 and 1,093 kg-CO2/m^2 in total. CO2 equivalent emissions (CO2e) by Freon gases, contained in building materials, equipment and devices, were also calculated. As the results, CO2e by insulators was 2% of the building's EC and CO2e by refrigerants was 9%-12% of the building's EC. It is important to keep reducing emissions of Freon gases contained in refrigerators.展开更多
基金supported by the Opening Project of State key Laboratory of Networking and Switching Technology under Grant No.SKLNST-2010-1-03the National Natural Science Foundation of China under Grants No.U1333113,No.61303204+1 种基金the Sichuan Province seedling project under Grant No.2012ZZ036the Scientific Research Fund of Sichuan Normal University under Grant No.13KYL06
文摘To reduce energy consumption in cloud data centres,in this paper,we propose two algorithms called the Energy-aware Scheduling algorithm using Workload-aware Consolidation Technique(ESWCT) and the Energyaware Live Migration algorithm using Workload-aware Consolidation Technique(ELMWCT).As opposed to traditional energy-aware scheduling algorithms,which often focus on only one-dimensional resource,the two algorithms are based on the fact that multiple resources(such as CPU,memory and network bandwidth)are shared by users concurrently in cloud data centres and heterogeneous workloads have different resource consumption characteristics.Both algorithms investigate the problem of consolidating heterogeneous workloads.They try to execute all Virtual Machines(VMs) with the minimum amount of Physical Machines(PMs),and then power off unused physical servers to reduce power consumption.Simulation results show that both algorithms efficiently utilise the resources in cloud data centres,and the multidimensional resources have good balanced utilizations,which demonstrate their promising energy saving capability.
文摘The objective of this research is to quantify the EEC (embodied energy/CO2) of a building. The EEC represents the energy consumption and CO2 emissions at individual phases of a building's life-cycle, such as construction (including manufacture of materials and equipment), renewal (including repair work) and demolition. Energy and CO2 emission intensities in terms of 401 sectors were calculated, using the 2005 I-O (input-output) table in Japan. According to our case study conducted from the construction phase to demolition, the EC (embodied CO2) of an office building used for 60 years is 12,044 t-CO2 and 1,093 kg-CO2/m^2 in total. CO2 equivalent emissions (CO2e) by Freon gases, contained in building materials, equipment and devices, were also calculated. As the results, CO2e by insulators was 2% of the building's EC and CO2e by refrigerants was 9%-12% of the building's EC. It is important to keep reducing emissions of Freon gases contained in refrigerators.