We do a new Li-ion battery evaluation research on the effects of cell resistance and polariza- tion on the energy loss in batteries based on thermal property and heat generation behavior of battery. Series of 18650 ce...We do a new Li-ion battery evaluation research on the effects of cell resistance and polariza- tion on the energy loss in batteries based on thermal property and heat generation behavior of battery. Series of 18650 cells with different capacities and electrode materials are evalu- ated by measuring input and output energy which change with charge-discharge time and current. Based on the results of these tests, we build a model of energy loss in cells' charge- discharge process, which include Joule heat and polarization heat impact factors. It was reported that Joule heat was caused by cell resistance, which included De-resistance and reaction resistance, and reaction resistance could not be easily obtained through routine test method. Using this new method, we can get the total resistance R and the polarization parameter U. The relationship between R, η, and temperature is also investigated in order to build a general model for series of different Li-ion batteries, and the research can be used in the performance evaluation, state of charge prediction and the measuring of consistency of the batteries.展开更多
In this paper, the influence of low power factor on electricity system and the influence of paper breaking on heat system are presented. For that, a mathematical model and a case study for a paper mill are realised. T...In this paper, the influence of low power factor on electricity system and the influence of paper breaking on heat system are presented. For that, a mathematical model and a case study for a paper mill are realised. The electric mathematical model is based on the relations of energy losses in cables and in transformers as a function of power factor. The thermal mathematical model includes characteristic energy and efficiency of boiler depending on its load. Characteristic of efficiency is modeled by a quadratic dependence between fuel consumption and steam flow. In the case, study were estimated to reduce energy losses for factor neutral (0.92) against real power factor (0.75) for the electrical scheme of a paper machine. Analytical expression of the boiler characteristic and variation of boiler efficiency depending on its load were estimated, too.展开更多
文摘We do a new Li-ion battery evaluation research on the effects of cell resistance and polariza- tion on the energy loss in batteries based on thermal property and heat generation behavior of battery. Series of 18650 cells with different capacities and electrode materials are evalu- ated by measuring input and output energy which change with charge-discharge time and current. Based on the results of these tests, we build a model of energy loss in cells' charge- discharge process, which include Joule heat and polarization heat impact factors. It was reported that Joule heat was caused by cell resistance, which included De-resistance and reaction resistance, and reaction resistance could not be easily obtained through routine test method. Using this new method, we can get the total resistance R and the polarization parameter U. The relationship between R, η, and temperature is also investigated in order to build a general model for series of different Li-ion batteries, and the research can be used in the performance evaluation, state of charge prediction and the measuring of consistency of the batteries.
文摘In this paper, the influence of low power factor on electricity system and the influence of paper breaking on heat system are presented. For that, a mathematical model and a case study for a paper mill are realised. The electric mathematical model is based on the relations of energy losses in cables and in transformers as a function of power factor. The thermal mathematical model includes characteristic energy and efficiency of boiler depending on its load. Characteristic of efficiency is modeled by a quadratic dependence between fuel consumption and steam flow. In the case, study were estimated to reduce energy losses for factor neutral (0.92) against real power factor (0.75) for the electrical scheme of a paper machine. Analytical expression of the boiler characteristic and variation of boiler efficiency depending on its load were estimated, too.