In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The...In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The device used accumulators as power source and a united function cylinder, which can realized the large flow-rate output for the test system.Analyzed the test data and made a particular research on the test device by testing different flow-rate safety valves;it verifies that the test device can be used tode-sign larger flow-rate safety valve test system and can make the flow-rate test and analysis and dynamic characteristics for the large-flow safety valve.展开更多
Energy consumed by distribution valves causes an energy loss for the output energy of hydraulic breakers, which has a significant influence on its efficiency. A new type of distribution valve used for hydraulic breake...Energy consumed by distribution valves causes an energy loss for the output energy of hydraulic breakers, which has a significant influence on its efficiency. A new type of distribution valve used for hydraulic breakers, de- signed to reduce energy consumption, is analyzed on the basis of the operating principle and energy loss of the current distribution valve. The new distribution valve adopts a cone valve and the optimization technique of unequal open de- gree for the valve port. Theoretical calculations and analyses have proven that the new distribution valve can reduce en- ergy loss by 9.0127J, or energy consumption by 31%, during an impact cycle and the efficiency of the hydraulic breaker can be raised by 4.5%. It has the following characteristics: little leakage, little pressure loss and low energy consump- tion.展开更多
A novel tuned liquid damper (TLD) rectangular tank with two angle-adjustable baffles was pre- sented.The numerical analysis was performed using the commercial code FLUENT.The standard kinetic energy and dissipation ra...A novel tuned liquid damper (TLD) rectangular tank with two angle-adjustable baffles was pre- sented.The numerical analysis was performed using the commercial code FLUENT.The standard kinetic energy and dissipation rate turbulent model was employed,which was solved using volume of fluid (VOF) method able to treat both the free surface motion and the viscous stresses over the rigid walls accurately.The relationship between the natural periods of water and the angles of its baffles was studied by numerical sim- ulating of a case,and the changes of energy dissipations were investigated.The natural periods and dampers of the novel TLD can be changed in a wide range by adjusting the baffles' angle,thus it is more effective in controlling the vibration of structures in a wide frequency range.展开更多
基金Supported by China Coal Research Institute Innovation Item(2007CX06)
文摘In order to solve the problem of property test of large flow-rate safety, the property parameter of safety valve test system was analyzed, and a device for property oflarge flow-rate safety valve test was designed.The device used accumulators as power source and a united function cylinder, which can realized the large flow-rate output for the test system.Analyzed the test data and made a particular research on the test device by testing different flow-rate safety valves;it verifies that the test device can be used tode-sign larger flow-rate safety valve test system and can make the flow-rate test and analysis and dynamic characteristics for the large-flow safety valve.
基金Project 50374071 supported by National Natural Science Foundation of China
文摘Energy consumed by distribution valves causes an energy loss for the output energy of hydraulic breakers, which has a significant influence on its efficiency. A new type of distribution valve used for hydraulic breakers, de- signed to reduce energy consumption, is analyzed on the basis of the operating principle and energy loss of the current distribution valve. The new distribution valve adopts a cone valve and the optimization technique of unequal open de- gree for the valve port. Theoretical calculations and analyses have proven that the new distribution valve can reduce en- ergy loss by 9.0127J, or energy consumption by 31%, during an impact cycle and the efficiency of the hydraulic breaker can be raised by 4.5%. It has the following characteristics: little leakage, little pressure loss and low energy consump- tion.
基金The Research Found of Shanghai Municipal Science and Technology Commission(No.052012014)
文摘A novel tuned liquid damper (TLD) rectangular tank with two angle-adjustable baffles was pre- sented.The numerical analysis was performed using the commercial code FLUENT.The standard kinetic energy and dissipation rate turbulent model was employed,which was solved using volume of fluid (VOF) method able to treat both the free surface motion and the viscous stresses over the rigid walls accurately.The relationship between the natural periods of water and the angles of its baffles was studied by numerical sim- ulating of a case,and the changes of energy dissipations were investigated.The natural periods and dampers of the novel TLD can be changed in a wide range by adjusting the baffles' angle,thus it is more effective in controlling the vibration of structures in a wide frequency range.