期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
基于雷达脉内特征的数据库识别方法
1
作者 樊永超 《信息记录材料》 2023年第2期1-3,共3页
在雷达侦察告警设备中,雷达的脉内调制特征已成为数据库识别的重要信息之一。由于通常的脉内信息提取算法耗时较多,无法满足工程的实时性要求。本文通过算法优化,准实时地提取一些简单的脉内信息特征并用于识别,可以提高数据库识别的准... 在雷达侦察告警设备中,雷达的脉内调制特征已成为数据库识别的重要信息之一。由于通常的脉内信息提取算法耗时较多,无法满足工程的实时性要求。本文通过算法优化,准实时地提取一些简单的脉内信息特征并用于识别,可以提高数据库识别的准确性。 展开更多
关键词 脉内特性 数据库识别 准实时处理方式
下载PDF
Cell Area and Strut Distribution Changes of Bent Coronary Stents:A Finite Element Analysis
2
作者 ZHAO Yang WU Wei +1 位作者 YANG Da-zhi QI Min 《Chinese Journal of Biomedical Engineering(English Edition)》 2009年第1期40-46,共7页
Coronary stents are metal coils or mesh tubes delivered to blocked vessels through catheters, whic Recently, special drugs h are expanded by balloons to reopen and scaffold target vessels. are carried by stents (drug... Coronary stents are metal coils or mesh tubes delivered to blocked vessels through catheters, whic Recently, special drugs h are expanded by balloons to reopen and scaffold target vessels. are carried by stents (drug-eluting stents) to further reduce instent restenosis rate after stenting procedure. However, continual study on biomechanical characteristics of stents is necessary provide a more suitable drug loading for better interactions between stents and tissue, or to platform for drug-eluting stents. The purpose of this paper is to show how finite element methods can be used to study cell area and strut distribution changes of bent coronary stents. A same bending deformation was applied to two commercial coronary stent models by a rigid curved vessel. Results show that the stent design influenced the changes of cell area and strut distribution under bending situation. The stent with links had more cell area changes at outer curvature, and the stent with peak-peak ( 〉 〈 ) strut design could have strut contact and overlapping at inner curvature. In conclusion, this finite element method can be used to study and compare cell area and strut distribution changes of bent stents, and to provide a convenient tool for designers in testing and improving biomechanical characteristics of new stents. 展开更多
关键词 coronary stents biomechanical characteristics cell area tissue prolapse strut distribution finite element methods
下载PDF
Characteristic of rich-mixture ignition kernel driven by nanosecond repetitive pulsed discharge 被引量:1
3
作者 LIN BingXuan WU Yun +4 位作者 LI YiWen JIA Min ZONG HaoHua DING Jian LI YingHong 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2016年第1期109-116,共8页
Plasma-assisted ignition is a promising technology to improve engine performance. Nanosecond repetitive pulsed discharge is widely used in plasma-assisted ignition owing to its chemical activations and thermal and hyd... Plasma-assisted ignition is a promising technology to improve engine performance. Nanosecond repetitive pulsed discharge is widely used in plasma-assisted ignition owing to its chemical activations and thermal and hydrodynamic expansions. However, the influence of ultrafast heating and hydrodynamic effects on the development of the rich-mixture ignition kernel is largely unknown. The present study aims to illustrate these effects using electrical and schlieren measurement. The number and the frequency of discharge pulses are exactly controlled to establish the relationship among the discharge energy, frequency, and rich-mixture ignition-kernel characteristics. The evolution of the ignition kernel in the early stage is mainly dominated by the discharge energy and frequency, i.e., a greater energy and a higher frequency yield a larger ignition kernel. Moreover, the influence of both the energy and frequency on the ignition kernel gradually disappears as the ignition kernel develops. According to the experimental data and theoretical analysis, the calculated laminar burning velocity is 0.319 m/s with a Markstein length of 13.43±0.11 cm when the voltage is 5.9 k V, the frequency is 3 k Hz, and the equivalence ratio is 1.3. This result indicates that the rich-mixture flame is stable in the early stage of ignition. 展开更多
关键词 plasma-assisted ignition NRP discharge rich-mixture ignition kernel laminar burning velocity markstein length
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部