为了解决T-TDR(Thermo-time domain reflectometry)探针短,土壤含水率测量效果差等技术问题,提出了一种低频滤波法LFF(Low frequency filter)进行TDR波形分析的计算模型。通过对TDR波形快速傅里叶变换,得到组成TDR波形的频谱,对其低频...为了解决T-TDR(Thermo-time domain reflectometry)探针短,土壤含水率测量效果差等技术问题,提出了一种低频滤波法LFF(Low frequency filter)进行TDR波形分析的计算模型。通过对TDR波形快速傅里叶变换,得到组成TDR波形的频谱,对其低频滤波后重新快速傅里叶反变换,可实现LFF变换。试验通过4种土壤,每种5个含水率的20个土样进行测试,通过LFF法和传统WINTDR法对比,结果表明LFF法具有较好的计算结果,其与干燥法的决定系数R2达0.983 5。LFF法不仅有效提高了T-TDR短针土壤含水率的测试精度,还简化了土壤含水率测试校验程序,提高了测试效率。展开更多
In order to improve the accuracy of cable fault position location at a low cost and make the testing results intuitive, a cable fault detector based on wave form reconstruction is designed. In this detector, the cable...In order to improve the accuracy of cable fault position location at a low cost and make the testing results intuitive, a cable fault detector based on wave form reconstruction is designed. In this detector, the cable fault position is located based on the time-domain pulse reflection (TDR) principle. A pulse waveform is injected in the tested cable, and a high-speed comparator with changeable reference voltages is used to binarize the test pulse waveform to a binary sequence on a certain voltage. Through scanning the reference voltage in a full voltage range, multi-sequences are acquired to reconstruct the pulse waveform transmission in the cable, and then the pulse attenuation feature, electrical open circuit fault, electrical short circuit fault, and the fault position of the cable are diagnosed. Experimental results show that the designed cable fault detector can determine the fault type and its position of the cable being tested, and the testing results are intuitive.展开更多
Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method...Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method is presented in this short paper. This proposed study is significantly different from the conventional pulse tube method because of the capability for a single plane damped sine pulse wave to generate in the water-filled pulse tube with a regular waveform and short duration time of about 1ms. During the generation process of the pulse, an inverse filter principle was adopted to compensate the transducer response. The effect of the characteristics of tube termination can be eliminated through the generation process of the pulse. Reflection coefficient from a water/air interface was measured to verify the proposed method. When compared with the expected theoretical values, a relatively good agreement can be obtained in the low frequency range of 500-2 000 Hz.展开更多
This article reviews my new optical fiber sensing (OFS) research activities in China for the last ten years at Chongqing University and University of Electronic Science and Technology of China, since I returned from...This article reviews my new optical fiber sensing (OFS) research activities in China for the last ten years at Chongqing University and University of Electronic Science and Technology of China, since I returned from UK in 1999. The research progress in long period fiber gratings (LPFGs), distributed fiber sensing systems and microfiber sensors is introduced. For LPFGs, the processing method with high-frequency CO2 laser pulses types of LPFGs fabricated and the related applications for both optical sensing and optical communication are described. For distributed fiber sensing systems, the fiber-optic polarization optical time domain reflectometer (POTDR), fiber-optic phase-sensitive optical time domain reflectometer (φ-OTDR) and Brillouin optical time-domain analyzer (BOTDA) are developed, respectively. For microfiber sensors, we mainly focus on the knot resonator and its application for sensing of the refractive index and acceleration, etc.展开更多
We propose a fully distributed fusion system combining phase-sensitive optical time-domain reflectometry(Φ-OTDR) and OTDR for synchronous vibration and loss measurement by setting an ingenious frequency sweep rate(FS...We propose a fully distributed fusion system combining phase-sensitive optical time-domain reflectometry(Φ-OTDR) and OTDR for synchronous vibration and loss measurement by setting an ingenious frequency sweep rate(FSR) of the optical source. The relationships between FSR, probe pulse width and repeat period are given to balance the amplitude fluctuation of OTDR traces, the dead zone probability and the measurable frequency range of vibration events. In the experiment, we achieve synchronous vibration and loss measurement with FSR of 40 MHz/s, the proble pulse width of 100 ns and repeat rate of 0.4 ms. The fluctuation of OTDR trace is less than 0.45 dB when the signalto-noise ratio(SNR) is over 12 dB for a captured vibration event located at 9.1 km. The proposed method can be used for not only detection but also early warning of damage events in optical communication networks.展开更多
基金The National Natural Science Foundation of China(No.61240032)the Natural Science Foundation of Jiangsu Province(No.BK2012560)+1 种基金the College Scientific and Technological Achievements Transformation Promotion Project of Jiangsu Province(No.JH-05)the Science and Technology Support Program of Jiangsu Province(No.BE2012740)
文摘In order to improve the accuracy of cable fault position location at a low cost and make the testing results intuitive, a cable fault detector based on wave form reconstruction is designed. In this detector, the cable fault position is located based on the time-domain pulse reflection (TDR) principle. A pulse waveform is injected in the tested cable, and a high-speed comparator with changeable reference voltages is used to binarize the test pulse waveform to a binary sequence on a certain voltage. Through scanning the reference voltage in a full voltage range, multi-sequences are acquired to reconstruct the pulse waveform transmission in the cable, and then the pulse attenuation feature, electrical open circuit fault, electrical short circuit fault, and the fault position of the cable are diagnosed. Experimental results show that the designed cable fault detector can determine the fault type and its position of the cable being tested, and the testing results are intuitive.
基金Supported by the National Natural Science Foundation of China under Grant No. 11204242 China Postdoctoral Foundation under Grant No. 2011M501477
文摘Based on existing low-frequency water-filled impedance tube testing facilities, which is a part of the Low Frequency Facility of the Naval Undersea Warfare Center in Beijing, an improved water-filled pulse tube method is presented in this short paper. This proposed study is significantly different from the conventional pulse tube method because of the capability for a single plane damped sine pulse wave to generate in the water-filled pulse tube with a regular waveform and short duration time of about 1ms. During the generation process of the pulse, an inverse filter principle was adopted to compensate the transducer response. The effect of the characteristics of tube termination can be eliminated through the generation process of the pulse. Reflection coefficient from a water/air interface was measured to verify the proposed method. When compared with the expected theoretical values, a relatively good agreement can be obtained in the low frequency range of 500-2 000 Hz.
文摘This article reviews my new optical fiber sensing (OFS) research activities in China for the last ten years at Chongqing University and University of Electronic Science and Technology of China, since I returned from UK in 1999. The research progress in long period fiber gratings (LPFGs), distributed fiber sensing systems and microfiber sensors is introduced. For LPFGs, the processing method with high-frequency CO2 laser pulses types of LPFGs fabricated and the related applications for both optical sensing and optical communication are described. For distributed fiber sensing systems, the fiber-optic polarization optical time domain reflectometer (POTDR), fiber-optic phase-sensitive optical time domain reflectometer (φ-OTDR) and Brillouin optical time-domain analyzer (BOTDA) are developed, respectively. For microfiber sensors, we mainly focus on the knot resonator and its application for sensing of the refractive index and acceleration, etc.
基金supported by the National Natural Science Foundation of China(Nos.61405090,61307096 and 61540017)
文摘We propose a fully distributed fusion system combining phase-sensitive optical time-domain reflectometry(Φ-OTDR) and OTDR for synchronous vibration and loss measurement by setting an ingenious frequency sweep rate(FSR) of the optical source. The relationships between FSR, probe pulse width and repeat period are given to balance the amplitude fluctuation of OTDR traces, the dead zone probability and the measurable frequency range of vibration events. In the experiment, we achieve synchronous vibration and loss measurement with FSR of 40 MHz/s, the proble pulse width of 100 ns and repeat rate of 0.4 ms. The fluctuation of OTDR trace is less than 0.45 dB when the signalto-noise ratio(SNR) is over 12 dB for a captured vibration event located at 9.1 km. The proposed method can be used for not only detection but also early warning of damage events in optical communication networks.