Based on the study of the harmonic suppression on DC side of the multi-pulse rectification system,a software platform is established in Matlab environment.The phase-shift angle is studied from the aspects of system st...Based on the study of the harmonic suppression on DC side of the multi-pulse rectification system,a software platform is established in Matlab environment.The phase-shift angle is studied from the aspects of system stability and economy,analyzing the effects of phase-shift angle on the input-side line current,the output-side voltage ripple,the equivalent capacity of autotransformer and other auxiliary devices in 12-pulse rectifier system.The software platform can complete the analysis only by inputting the initial conditions,eliminating the derivation of the intermediate formula and reducing the complexity of the system analysis,and have good scalability.The simulation results show that the system can effectively analyze the influence of phase angle on 12-pulse star-connected transformer.展开更多
To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current i...To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current inverter to generate compensating currents and injecting the currents directly into the DC side of the system,the grid-side currents of the rectifier can be approximated to sine wave.Using zigzag autotransformer as phase-shifting transformer can block the zero sequence current components and reduce the equivalent capacity of the rectifying system.The study on harmonic distortion rate of grid-side currents with the variation of the load shows that the harmonic content of the compensated rectifier decreases significantly under various load conditions.The harmonic content of the grid-side currents of the proposed active injection rectifier is only 1.17%,and the equivalent capacity of the rectifier is calculated.The results show that the rectifier can not only suppress the harmonic currents,but also have a lower equivalent capacity.展开更多
基金National Natural Science Foundation of China(Nos.51367010,51867012)Lanzhou City Talent Innovation and Entrepreneurship Science and Technology Program Subsidy(No.2017-RC-51)。
文摘Based on the study of the harmonic suppression on DC side of the multi-pulse rectification system,a software platform is established in Matlab environment.The phase-shift angle is studied from the aspects of system stability and economy,analyzing the effects of phase-shift angle on the input-side line current,the output-side voltage ripple,the equivalent capacity of autotransformer and other auxiliary devices in 12-pulse rectifier system.The software platform can complete the analysis only by inputting the initial conditions,eliminating the derivation of the intermediate formula and reducing the complexity of the system analysis,and have good scalability.The simulation results show that the system can effectively analyze the influence of phase angle on 12-pulse star-connected transformer.
基金National Natural Science Foundation of China(No.51767013)Science and Technology Research and Development Plan of China Railway Corporation(No.2017J012-A)Lanzhou City Science and Technology Program for Innovation and Entrepreneurship of Talents(No.2017-RC-51)。
文摘To improve the harmonic suppression ability of multi-pulse rectifier,a 12-pulse rectifier based on zigzag autotransformer by DC side active compensation strategy is proposed.By controlling the small capacity current inverter to generate compensating currents and injecting the currents directly into the DC side of the system,the grid-side currents of the rectifier can be approximated to sine wave.Using zigzag autotransformer as phase-shifting transformer can block the zero sequence current components and reduce the equivalent capacity of the rectifying system.The study on harmonic distortion rate of grid-side currents with the variation of the load shows that the harmonic content of the compensated rectifier decreases significantly under various load conditions.The harmonic content of the grid-side currents of the proposed active injection rectifier is only 1.17%,and the equivalent capacity of the rectifier is calculated.The results show that the rectifier can not only suppress the harmonic currents,but also have a lower equivalent capacity.