Polyvinyl alcohol (PVA)-containing desizing wastewater was treated by various wet oxidation methods.Parameters such as reaction temperature, initial solution pH, and the dosage of H2O2 were investigated in terms of ch...Polyvinyl alcohol (PVA)-containing desizing wastewater was treated by various wet oxidation methods.Parameters such as reaction temperature, initial solution pH, and the dosage of H2O2 were investigated in terms of chemical oxygen demand (CODcr) and total organic carbon (TOC) removal rate. Up to 90% of the initial CODcr was removed by wet air oxidation(WAO) at 270℃ with stoichiometric oxygen supply, while at temperature of 200℃, the CODcr removal rate was found to be 80%. Similar results were obtained by Promoted WAO (PWAO) and wet peroxide oxidation(WPO) at a lower temperature of 150℃. Reaction temperature was found to have a significant effect on the oxidation performance for all the methods. Initial solution pH was observed to play a significant role in PWAO and WPO where H2O2 was employed. Comparison of WAO, CWAO(catalytic wet air oxidation), PWAO and WPO shows that the rate of CODcr removal increases in the order: WAO, CWAO, PWAO and WPO.展开更多
The dewaterability of activated sludge conditioned by chitosan flocculant was studied. The effects of chitosan characteristics such as molecular weight, degree of deacetylation, and dose on the dewaterability were inv...The dewaterability of activated sludge conditioned by chitosan flocculant was studied. The effects of chitosan characteristics such as molecular weight, degree of deacetylation, and dose on the dewaterability were investigated. The sludge dewaterability is evaluated in terms of specific resistance to filtration, residual turbidity of supernatant, moisture content of cake, and settling rate. Sludge dehydrating behaviors conditioned with CTS, PAM and PAC flocculants were compared. The conditioning was also carried out with dual flocculants in two stages. It is found that the sludge conditioned with CTS has better dewaterability than that with PAC. The optimum conditions with chitosan are: dose 0.8 - 1.2 g per 100 g dry cake, molecular weight 300,000, and degree of deacetylation 70%. The conditioning in two stages with dual flocculants is found to be more effective than that with single flocculant.展开更多
文摘Polyvinyl alcohol (PVA)-containing desizing wastewater was treated by various wet oxidation methods.Parameters such as reaction temperature, initial solution pH, and the dosage of H2O2 were investigated in terms of chemical oxygen demand (CODcr) and total organic carbon (TOC) removal rate. Up to 90% of the initial CODcr was removed by wet air oxidation(WAO) at 270℃ with stoichiometric oxygen supply, while at temperature of 200℃, the CODcr removal rate was found to be 80%. Similar results were obtained by Promoted WAO (PWAO) and wet peroxide oxidation(WPO) at a lower temperature of 150℃. Reaction temperature was found to have a significant effect on the oxidation performance for all the methods. Initial solution pH was observed to play a significant role in PWAO and WPO where H2O2 was employed. Comparison of WAO, CWAO(catalytic wet air oxidation), PWAO and WPO shows that the rate of CODcr removal increases in the order: WAO, CWAO, PWAO and WPO.
文摘The dewaterability of activated sludge conditioned by chitosan flocculant was studied. The effects of chitosan characteristics such as molecular weight, degree of deacetylation, and dose on the dewaterability were investigated. The sludge dewaterability is evaluated in terms of specific resistance to filtration, residual turbidity of supernatant, moisture content of cake, and settling rate. Sludge dehydrating behaviors conditioned with CTS, PAM and PAC flocculants were compared. The conditioning was also carried out with dual flocculants in two stages. It is found that the sludge conditioned with CTS has better dewaterability than that with PAC. The optimum conditions with chitosan are: dose 0.8 - 1.2 g per 100 g dry cake, molecular weight 300,000, and degree of deacetylation 70%. The conditioning in two stages with dual flocculants is found to be more effective than that with single flocculant.