A series of electrochemical and long-term corrosion tests were carried out in a neutral saline (5%NaCl) vapor of 35 °C on thermal sprayed WC cermet coatings containing different kinds of metallic binders in ord...A series of electrochemical and long-term corrosion tests were carried out in a neutral saline (5%NaCl) vapor of 35 °C on thermal sprayed WC cermet coatings containing different kinds of metallic binders in order to examine the effect of composition of binder materials on the corrosion behavior. The experimental results revealed that the overall corrosion resistance of WC-Co coating was inferior to that of WC-Co-Cr coating. For the coatings without Cr, WC-Co, general corrosion occurred in binder materials in addition to galvanic corrosion between WC particles and metallic binders in the neutral environment. By contrast, the formation of passive film in the form of surface oxide in the coatings containing Cr, WC-Co-Cr, suppressed the binder and metallic binders to be eroded. It is found that the chemical composition of metallic binder materials is one of the important factors influencing the corrosion resistance of HVOF sprayed WC cermet coatings in the neutral vapor.展开更多
Colorful thin oxide films were synthesized by galvanostatic anodization on Ti−6Al−4V alloy.Three different aqueous solutions containing corrosion inorganic inhibitors(Na_(2)MoO_(4),NaH_(2)PO_(4) and NH4VO3)were employ...Colorful thin oxide films were synthesized by galvanostatic anodization on Ti−6Al−4V alloy.Three different aqueous solutions containing corrosion inorganic inhibitors(Na_(2)MoO_(4),NaH_(2)PO_(4) and NH4VO3)were employed for the anodization treatment.The effect of inhibitor anions on the corrosion behavior of the alloy in Ringer solution was studied.Open circuit potential(OCP),Tafel polarization,linear sweep voltammetry(LSV)and chronoamperometry(CA)were performed to evaluate the corrosion performance of the treated electrodes.The incorporation of the inhibitor ions was detected by the release of Mo,V and P through ICP-AES technique.The formed oxides were characterized by scanning electron microscopy(SEM),X-ray diffraction(XRD)and X-ray photoelectron spectroscopy(XPS).The results show that compact,amorphous oxides without pores or cracks were obtained independently of the solution used.The sample anodized in Na_(2)MoO_(4) solution registered the lowest corrosion current density(0.11μA/cm^(2)),and it was able to protect the alloy even after 168 h of immersion in Ringer solution.No cracks or corrosion products were detected.The XPS analysis reveals the incorporation of molybdenum to the oxide film in the form of Mo^(6+) and Mo^(4+).展开更多
Stress corrosion cracking (SCC) and anticorrosion measures of TU42C weld-joint were studied by constant load experiments and pickling experiments. The results show that in 40%(mass fraction) NaOH solution at 110℃, ca...Stress corrosion cracking (SCC) and anticorrosion measures of TU42C weld-joint were studied by constant load experiments and pickling experiments. The results show that in 40%(mass fraction) NaOH solution at 110℃, caustic SCC occurs in TU42C weld-joints at the applied potential of-1020mV(vs SCE) for 3d while at the potential of-950mV(vs SCE) for 10d. All the cracks are intergranular. In the 10% sulfuric acid, the cracks have the most negative self-corrosion potential-432.5mV(vs SCE) and are active to be further corroded by the acid. Because of the same corrosion behaviour as the lab weldment, preheater’s cracking in alumina factories is attributed to the combining actions of previous caustic SCC in Bayer solutions and continuous acid corrosion by pickling with the addition of RD. The following measures are effective to prevent the corrosion failure of preheater, such as postweld heat treatment at 620℃ to relax the residual weld stress, addition of CC3 and L826 as the corrosion inhibitors to improve the pickling and cleaning by the high pressure water instead of by pickling.展开更多
Polyacrylamide (PAM) film was electrosynthesized on mild steel by cyclic voltammetry using Ce (IV) salt-oxalic acid as supporting electrolyte. Polymerization was initiated by a free radical that was formed by the ...Polyacrylamide (PAM) film was electrosynthesized on mild steel by cyclic voltammetry using Ce (IV) salt-oxalic acid as supporting electrolyte. Polymerization was initiated by a free radical that was formed by the fast reaction of oxalic acid and Ce (IV). The electrolysis of the reaction solution resulted in regeneration of Ce (IV), which could oxidize oxalic acid to produce radicals. The effect of temperature on the yield of electroinitiated polymerization was performed. The potential sweep rates were changed to achieve the polymer film with different thickness. Protective properties of the PAM film for corrosion of mild steel in 1 M NaCI aqueous solution were investigated by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS). The structure of PAM film on mild steel was investigated by using physicochemical methods such as elemental analysis of C, H, N, physical chemical methods and FTIR spectrometer. The influence of scan repetition and scan rate on the formation of polymer film was studied at a current density of 1 mA/cm2. The results of these studies reveal that the corrosion resistance of the PAM-coated mild steel was significantly higher and the corrosion rate was considerably lower than that of uncoated steel. The PAM film was formed with lower sweep rate leading to more positive shift of corrosion potential and greater charge transfer resistance, reflecting higher inhibition for corrosion of the mild steel.展开更多
A new type of photoelectrochemical cathodic protection technology(a combination of seawater corrosion and biological fouling resistance)is being actively researched to alleviate the serious corrosion of marine metal m...A new type of photoelectrochemical cathodic protection technology(a combination of seawater corrosion and biological fouling resistance)is being actively researched to alleviate the serious corrosion of marine metal materials.At present,there is almost no research on anti-corrosion and anti-fouling dual functional materials.In this paper,Cu_(2)ZnSnS_(4)is attached to the surface of TiO,nanotubes through a one-step hydrothermal method for modification.The results indicate that when the hydrothermal reaction time is 24 h,Cu_(2)ZnSnS_(4)/TiO_(2)nanocomposite material exhibits excellent performance in coupling with the protected 304 SS,with its open circuit potential shifts negatively to-1.04 V.This material improves the separation efficiency of photogenerated electrons and effectively improves the photochemical cathodic protection of 304 stainless steel.The high removal rate of Staphylococcus aureus(up to 93%)of the as-prepared samples also proved that it has the effect of the anti-biological fouling.展开更多
文摘A series of electrochemical and long-term corrosion tests were carried out in a neutral saline (5%NaCl) vapor of 35 °C on thermal sprayed WC cermet coatings containing different kinds of metallic binders in order to examine the effect of composition of binder materials on the corrosion behavior. The experimental results revealed that the overall corrosion resistance of WC-Co coating was inferior to that of WC-Co-Cr coating. For the coatings without Cr, WC-Co, general corrosion occurred in binder materials in addition to galvanic corrosion between WC particles and metallic binders in the neutral environment. By contrast, the formation of passive film in the form of surface oxide in the coatings containing Cr, WC-Co-Cr, suppressed the binder and metallic binders to be eroded. It is found that the chemical composition of metallic binder materials is one of the important factors influencing the corrosion resistance of HVOF sprayed WC cermet coatings in the neutral vapor.
基金The financial supports of the Secretaría de Ciencia y Técnica-UNS (PGI 24/M159)the Consejo Nacional de Investigaciones Científicas y Técnicas (CONICET-PIP 112-20150-100147)the Agencia Nacional de Promoción Científica y Tecnológica (ANPCy T-PICT 2015-0726)。
文摘Colorful thin oxide films were synthesized by galvanostatic anodization on Ti−6Al−4V alloy.Three different aqueous solutions containing corrosion inorganic inhibitors(Na_(2)MoO_(4),NaH_(2)PO_(4) and NH4VO3)were employed for the anodization treatment.The effect of inhibitor anions on the corrosion behavior of the alloy in Ringer solution was studied.Open circuit potential(OCP),Tafel polarization,linear sweep voltammetry(LSV)and chronoamperometry(CA)were performed to evaluate the corrosion performance of the treated electrodes.The incorporation of the inhibitor ions was detected by the release of Mo,V and P through ICP-AES technique.The formed oxides were characterized by scanning electron microscopy(SEM),X-ray diffraction(XRD)and X-ray photoelectron spectroscopy(XPS).The results show that compact,amorphous oxides without pores or cracks were obtained independently of the solution used.The sample anodized in Na_(2)MoO_(4) solution registered the lowest corrosion current density(0.11μA/cm^(2)),and it was able to protect the alloy even after 168 h of immersion in Ringer solution.No cracks or corrosion products were detected.The XPS analysis reveals the incorporation of molybdenum to the oxide film in the form of Mo^(6+) and Mo^(4+).
文摘Stress corrosion cracking (SCC) and anticorrosion measures of TU42C weld-joint were studied by constant load experiments and pickling experiments. The results show that in 40%(mass fraction) NaOH solution at 110℃, caustic SCC occurs in TU42C weld-joints at the applied potential of-1020mV(vs SCE) for 3d while at the potential of-950mV(vs SCE) for 10d. All the cracks are intergranular. In the 10% sulfuric acid, the cracks have the most negative self-corrosion potential-432.5mV(vs SCE) and are active to be further corroded by the acid. Because of the same corrosion behaviour as the lab weldment, preheater’s cracking in alumina factories is attributed to the combining actions of previous caustic SCC in Bayer solutions and continuous acid corrosion by pickling with the addition of RD. The following measures are effective to prevent the corrosion failure of preheater, such as postweld heat treatment at 620℃ to relax the residual weld stress, addition of CC3 and L826 as the corrosion inhibitors to improve the pickling and cleaning by the high pressure water instead of by pickling.
文摘Polyacrylamide (PAM) film was electrosynthesized on mild steel by cyclic voltammetry using Ce (IV) salt-oxalic acid as supporting electrolyte. Polymerization was initiated by a free radical that was formed by the fast reaction of oxalic acid and Ce (IV). The electrolysis of the reaction solution resulted in regeneration of Ce (IV), which could oxidize oxalic acid to produce radicals. The effect of temperature on the yield of electroinitiated polymerization was performed. The potential sweep rates were changed to achieve the polymer film with different thickness. Protective properties of the PAM film for corrosion of mild steel in 1 M NaCI aqueous solution were investigated by potentiodynamic polarization curves and electrochemical impedance spectroscopy (EIS). The structure of PAM film on mild steel was investigated by using physicochemical methods such as elemental analysis of C, H, N, physical chemical methods and FTIR spectrometer. The influence of scan repetition and scan rate on the formation of polymer film was studied at a current density of 1 mA/cm2. The results of these studies reveal that the corrosion resistance of the PAM-coated mild steel was significantly higher and the corrosion rate was considerably lower than that of uncoated steel. The PAM film was formed with lower sweep rate leading to more positive shift of corrosion potential and greater charge transfer resistance, reflecting higher inhibition for corrosion of the mild steel.
基金Projects(42106051,U2106206)supported by the National Natural Science Foundation of China。
文摘A new type of photoelectrochemical cathodic protection technology(a combination of seawater corrosion and biological fouling resistance)is being actively researched to alleviate the serious corrosion of marine metal materials.At present,there is almost no research on anti-corrosion and anti-fouling dual functional materials.In this paper,Cu_(2)ZnSnS_(4)is attached to the surface of TiO,nanotubes through a one-step hydrothermal method for modification.The results indicate that when the hydrothermal reaction time is 24 h,Cu_(2)ZnSnS_(4)/TiO_(2)nanocomposite material exhibits excellent performance in coupling with the protected 304 SS,with its open circuit potential shifts negatively to-1.04 V.This material improves the separation efficiency of photogenerated electrons and effectively improves the photochemical cathodic protection of 304 stainless steel.The high removal rate of Staphylococcus aureus(up to 93%)of the as-prepared samples also proved that it has the effect of the anti-biological fouling.