The Gaussian mixture model (GMM), k-nearest neighbor (k-NN), quadratic discriminant analysis (QDA), and linear discriminant analysis (LDA) were compared to classify wrist motions using surface electromyogram (EMG). Ef...The Gaussian mixture model (GMM), k-nearest neighbor (k-NN), quadratic discriminant analysis (QDA), and linear discriminant analysis (LDA) were compared to classify wrist motions using surface electromyogram (EMG). Effect of feature selection in EMG signal processing was also verified by comparing classification accuracy of each feature, and the enhancement of classification accuracy by normalization was confirmed. EMG signals were acquired from two electrodes placed on the forearm of twenty eight healthy subjects and used for recognition of wrist motion. Features were extracted from the obtained EMG signals in the time domain and were applied to classification methods. The difference absolute mean value (DAMV), difference absolute standard deviation value (DASDV), mean absolute value (MAV), root mean square (RMS) were used for composing 16 double features which were combined of two channels. In the classification methods, the highest accuracy of classification showed in the GMM. The most effective combination of classification method and double feature was (MAV, DAMV) of GMM and its classification accuracy was 96.85%. The results of normalization were better than those of non-normalization in GMM, k-NN, and LDA.展开更多
Volar perilunate fracture dislocation is an extremely rare carpal injury, but associated with metacarpophalangeal joint dislocation of both the ipsilateral index and middle finger has never been reported. We report on...Volar perilunate fracture dislocation is an extremely rare carpal injury, but associated with metacarpophalangeal joint dislocation of both the ipsilateral index and middle finger has never been reported. We report one case of a 28-year-old man following a high-energy trauma. After performing closed reduction of the metacarpophalangeal joint injury, open reduction of the wrist injury through volar approach was done, and a K-wire fixation was used to stabilize the scaphoid fracture and lunotriquetral joint. After a 16 months' follow-up period, the wrist regained a full range of motion without symptoms, and the fractured bone was strengthened in a good position.展开更多
We present the technical report for treat- ment of comminuted fracture of the capitate with ligamentotaxis. The base of third metacarpal was found to be fractured with comminution of the capitate. The decrease in carp...We present the technical report for treat- ment of comminuted fracture of the capitate with ligamentotaxis. The base of third metacarpal was found to be fractured with comminution of the capitate. The decrease in carpal height index and comminution of the third metacar- pal base lead to dilemma between conservative treatment and surgical management of this particular injury. The sur- gical management was chosen to maintain the carpal height index of the wrist to prevent the late degenerative changes.The patient was applied with external fixator in distraction mode expanning the wrist joint for six weeks, and the wrist was mobilised after removal of the fixator. It is shown that the external fixator in distraction mode expanning the wrist joint is a good alternative method for treatment of capitate fracture.展开更多
基金Project(NIPA-2012-H0401-12-1007) supported by the MKE(The Ministry of Knowledge Economy), Korea, supervised by the NIPAProject(2010-0020163) supported by Key Research Institute Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology, Korea
文摘The Gaussian mixture model (GMM), k-nearest neighbor (k-NN), quadratic discriminant analysis (QDA), and linear discriminant analysis (LDA) were compared to classify wrist motions using surface electromyogram (EMG). Effect of feature selection in EMG signal processing was also verified by comparing classification accuracy of each feature, and the enhancement of classification accuracy by normalization was confirmed. EMG signals were acquired from two electrodes placed on the forearm of twenty eight healthy subjects and used for recognition of wrist motion. Features were extracted from the obtained EMG signals in the time domain and were applied to classification methods. The difference absolute mean value (DAMV), difference absolute standard deviation value (DASDV), mean absolute value (MAV), root mean square (RMS) were used for composing 16 double features which were combined of two channels. In the classification methods, the highest accuracy of classification showed in the GMM. The most effective combination of classification method and double feature was (MAV, DAMV) of GMM and its classification accuracy was 96.85%. The results of normalization were better than those of non-normalization in GMM, k-NN, and LDA.
文摘Volar perilunate fracture dislocation is an extremely rare carpal injury, but associated with metacarpophalangeal joint dislocation of both the ipsilateral index and middle finger has never been reported. We report one case of a 28-year-old man following a high-energy trauma. After performing closed reduction of the metacarpophalangeal joint injury, open reduction of the wrist injury through volar approach was done, and a K-wire fixation was used to stabilize the scaphoid fracture and lunotriquetral joint. After a 16 months' follow-up period, the wrist regained a full range of motion without symptoms, and the fractured bone was strengthened in a good position.
文摘We present the technical report for treat- ment of comminuted fracture of the capitate with ligamentotaxis. The base of third metacarpal was found to be fractured with comminution of the capitate. The decrease in carpal height index and comminution of the third metacar- pal base lead to dilemma between conservative treatment and surgical management of this particular injury. The sur- gical management was chosen to maintain the carpal height index of the wrist to prevent the late degenerative changes.The patient was applied with external fixator in distraction mode expanning the wrist joint for six weeks, and the wrist was mobilised after removal of the fixator. It is shown that the external fixator in distraction mode expanning the wrist joint is a good alternative method for treatment of capitate fracture.