The basic idea of intrinsically safe circuit and the discharge spark in the Buck converter in the explosive at- mospheres were introduced. The Buck converter is the main topological structure of the switch type of int...The basic idea of intrinsically safe circuit and the discharge spark in the Buck converter in the explosive at- mospheres were introduced. The Buck converter is the main topological structure of the switch type of intrinsically safe circuit, which has two working modes: continuous inductive current (CCM — continuous conduction mode) and dis- crete inductance current (DCM — discontinuous conduction mode). The operating state of the continuous inductive current mode is analyzed in detail and the energy of discharge spark in various operating modes is discussed. The total energy will decrease with the increase of switch frequency, in a switching cycle; the discharge spark energy has a maxi- mum and a minimum value. Therefore, the Buck converter has smaller discharge spark energy than the linear power circuit and the switch type of intrinsically safe circuit can enhance the output power and the conversion efficiency of the intrinsically safe power.展开更多
Given the actual working of a fully mechanized plough at a mining face, we have proposed a formula for running constraints between powered supports and a coal plough under assumed geological conditions of the coal fac...Given the actual working of a fully mechanized plough at a mining face, we have proposed a formula for running constraints between powered supports and a coal plough under assumed geological conditions of the coal face and, on this basis, established an automatic control model of powered supports for the coal plough face. We introduced the working principle of the powered support control system of the plough at the mining face. We established three advanced characteristics of this control system: response speed, reliability and easy maintenance of the system. As well, we briefly introduced, the principal function of primary and subordinate controllers and the realization of the communication system by a Single Bus. Ten controllers were constructed and tested in our laboratorium. The results show that the control model is practical and meets actual conditions. It provides a theoretical basis for designing a comouter control system for a oowered support system of a plough at a mining face.展开更多
文摘The basic idea of intrinsically safe circuit and the discharge spark in the Buck converter in the explosive at- mospheres were introduced. The Buck converter is the main topological structure of the switch type of intrinsically safe circuit, which has two working modes: continuous inductive current (CCM — continuous conduction mode) and dis- crete inductance current (DCM — discontinuous conduction mode). The operating state of the continuous inductive current mode is analyzed in detail and the energy of discharge spark in various operating modes is discussed. The total energy will decrease with the increase of switch frequency, in a switching cycle; the discharge spark energy has a maxi- mum and a minimum value. Therefore, the Buck converter has smaller discharge spark energy than the linear power circuit and the switch type of intrinsically safe circuit can enhance the output power and the conversion efficiency of the intrinsically safe power.
基金Project 104030 supported by the Ministry of Education of the People’s Republic of China
文摘Given the actual working of a fully mechanized plough at a mining face, we have proposed a formula for running constraints between powered supports and a coal plough under assumed geological conditions of the coal face and, on this basis, established an automatic control model of powered supports for the coal plough face. We introduced the working principle of the powered support control system of the plough at the mining face. We established three advanced characteristics of this control system: response speed, reliability and easy maintenance of the system. As well, we briefly introduced, the principal function of primary and subordinate controllers and the realization of the communication system by a Single Bus. Ten controllers were constructed and tested in our laboratorium. The results show that the control model is practical and meets actual conditions. It provides a theoretical basis for designing a comouter control system for a oowered support system of a plough at a mining face.