To ensure revulsive driving of intelligent vehicles at intersections, a method is presented to detect and recognize the traffic lights. First, the stabling siding at intersections is detected by applying Hough transfo...To ensure revulsive driving of intelligent vehicles at intersections, a method is presented to detect and recognize the traffic lights. First, the stabling siding at intersections is detected by applying Hough transformation. Then, the colors of traffic lights are detected with color space transformation. Finally, self-associative memory is used to recognize the countdown characters of the traffic lights. Test results at 20 real intersections show that the ratio of correct stabling siding recognition reaches up to 90%;and the ratios of recognition of traffic lights and divided characters are 85% and 97%, respectively. The research proves that the method is efficient for the detection of stabling siding and is robust enough to recognize the characters from images with noise and broken edges.展开更多
A method was demonstrated based on Infomax independent component analysis(Infomax ICA) for automatically extracting auditory P300 signals within several trials. A signaling equilibrium algorithm was proposed to enhanc...A method was demonstrated based on Infomax independent component analysis(Infomax ICA) for automatically extracting auditory P300 signals within several trials. A signaling equilibrium algorithm was proposed to enhance the effectiveness of the Infomax ICA decomposition. After the mixed signal was decomposed by Infomax ICA, the independent component(IC) used in auditory P300 reconstruction was automatically chosen by using the standard deviation of the fixed temporal pattern. And the result of auditory P300 was reconstructed using the selected ICs. The experimental results show that the auditory P300 can be detected automatically within five trials. The Pearson correlation coefficient between the standard signal and the signal detected using the proposed method is significantly greater than that between the standard signal and the signal detected using the average method within five trials. The wave pattern result obtained using the proposed algorithm is better and more similar to the standard signal than that obtained by the average method for the same number of trials. Therefore, the proposed method can automatically detect the effective auditory P300 within several trials.展开更多
AIM:To investigate the performance of a new software-based colonoscopy quality assessment system.METHODS:The software-based system employs a novel image processing algorithm which detects the levels of image clarity,w...AIM:To investigate the performance of a new software-based colonoscopy quality assessment system.METHODS:The software-based system employs a novel image processing algorithm which detects the levels of image clarity,withdrawal velocity,and level of the bowel preparation in a real-time fashion from live video signal.Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists.Subsequently,an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization(scored 1-5;1,when the percentage was 1%-20%;2,when the percentage was 21%-40%,etc.).In order to test the proposed velocity and blurriness thresholds,screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected,automatically processed and rated.Quality ratings on the withdrawal were compared to the insertion in the same patients.Then,3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal(scored 1-5;1,poor;3,average;5,excellent) based on 3 major aspects:image quality,colon preparation,and withdrawal velocity.The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient.RESULTS:Fourteen screening colonoscopies were assessed.Adenomatous polyps were detected in 4/14(29%) of the collected colonoscopy video samples.As a proof of concept,the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps(average percent time with adequate visualization:79% ± 5% for withdrawal and 50% ± 14% for insertion,P < 0.01).Withdrawal times during which no polyps were removed ranged from 4-12 min.The median quality rating from the automated system and the reviewers was 3.45 [interquartile range(IQR),3.1-3.68] and 3.00(IQR,2.33-3.67) respectively for all colonoscopy video samples.The automated rating revealed a strong correlation with the reviewer's rating(ρ coefficient= 0.65,P = 0.01).There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating(Spearman r coefficient= 0.59,P = 0.03).There was no correlation of automated overall quality rating with mean endoscopists image quality rating(Spearman r coefficient= 0.41,P = 0.15).CONCLUSION:The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments.Further study is required to validate this approach.展开更多
ECG is an important tool for the primary diagnosis of heart diseases, which shows the electrophysiology of the heart. In our method, a single maternal abdominal ECG signal is taken as an input signal and the maternal ...ECG is an important tool for the primary diagnosis of heart diseases, which shows the electrophysiology of the heart. In our method, a single maternal abdominal ECG signal is taken as an input signal and the maternal P-QRS-T complexes of original signal is averaged and repeated and taken as a reference signal. LMS and RL5 adaptive filters algorithms are applied. The results showed that the fetal ECGs have been successfully detected. The accuracy of Daisy database was up to 84% of LM5 and 88% of RLS while PhysioNet was up to 98% and 96% for LMS and RLS respectively.展开更多
基金The Cultivation Fund of the Key Scientific and Technical Innovation Project of Higher Education of Ministry of Education (No.705020)
文摘To ensure revulsive driving of intelligent vehicles at intersections, a method is presented to detect and recognize the traffic lights. First, the stabling siding at intersections is detected by applying Hough transformation. Then, the colors of traffic lights are detected with color space transformation. Finally, self-associative memory is used to recognize the countdown characters of the traffic lights. Test results at 20 real intersections show that the ratio of correct stabling siding recognition reaches up to 90%;and the ratios of recognition of traffic lights and divided characters are 85% and 97%, respectively. The research proves that the method is efficient for the detection of stabling siding and is robust enough to recognize the characters from images with noise and broken edges.
基金Projects(81460273,61265006)supported by the National Natural Science Foundation of ChinaProject(2013GXNSFAA019325)supported by Guangxi Natural Science Foundation,ChinaProject(1348020-10)supported by Guangxi Science and Technology Program,China
文摘A method was demonstrated based on Infomax independent component analysis(Infomax ICA) for automatically extracting auditory P300 signals within several trials. A signaling equilibrium algorithm was proposed to enhance the effectiveness of the Infomax ICA decomposition. After the mixed signal was decomposed by Infomax ICA, the independent component(IC) used in auditory P300 reconstruction was automatically chosen by using the standard deviation of the fixed temporal pattern. And the result of auditory P300 was reconstructed using the selected ICs. The experimental results show that the auditory P300 can be detected automatically within five trials. The Pearson correlation coefficient between the standard signal and the signal detected using the proposed method is significantly greater than that between the standard signal and the signal detected using the average method within five trials. The wave pattern result obtained using the proposed algorithm is better and more similar to the standard signal than that obtained by the average method for the same number of trials. Therefore, the proposed method can automatically detect the effective auditory P300 within several trials.
基金Supported by The Natural Sciences and Engineering Research Council of Canada (Partially)
文摘AIM:To investigate the performance of a new software-based colonoscopy quality assessment system.METHODS:The software-based system employs a novel image processing algorithm which detects the levels of image clarity,withdrawal velocity,and level of the bowel preparation in a real-time fashion from live video signal.Threshold levels of image blurriness and the withdrawal velocity below which the visualization could be considered adequate have initially been determined arbitrarily by review of sample colonoscopy videos by two experienced endoscopists.Subsequently,an overall colonoscopy quality rating was computed based on the percentage of the withdrawal time with adequate visualization(scored 1-5;1,when the percentage was 1%-20%;2,when the percentage was 21%-40%,etc.).In order to test the proposed velocity and blurriness thresholds,screening colonoscopy withdrawal videos from a specialized ambulatory colon cancer screening center were collected,automatically processed and rated.Quality ratings on the withdrawal were compared to the insertion in the same patients.Then,3 experienced endoscopists reviewed the collected videos in a blinded fashion and rated the overall quality of each withdrawal(scored 1-5;1,poor;3,average;5,excellent) based on 3 major aspects:image quality,colon preparation,and withdrawal velocity.The automated quality ratings were compared to the averaged endoscopist quality ratings using Spearman correlation coefficient.RESULTS:Fourteen screening colonoscopies were assessed.Adenomatous polyps were detected in 4/14(29%) of the collected colonoscopy video samples.As a proof of concept,the Colometer software rated colonoscope withdrawal as having better visualization than the insertion in the 10 videos which did not have any polyps(average percent time with adequate visualization:79% ± 5% for withdrawal and 50% ± 14% for insertion,P < 0.01).Withdrawal times during which no polyps were removed ranged from 4-12 min.The median quality rating from the automated system and the reviewers was 3.45 [interquartile range(IQR),3.1-3.68] and 3.00(IQR,2.33-3.67) respectively for all colonoscopy video samples.The automated rating revealed a strong correlation with the reviewer's rating(ρ coefficient= 0.65,P = 0.01).There was good correlation of the automated overall quality rating and the mean endoscopist withdrawal speed rating(Spearman r coefficient= 0.59,P = 0.03).There was no correlation of automated overall quality rating with mean endoscopists image quality rating(Spearman r coefficient= 0.41,P = 0.15).CONCLUSION:The results from a novel automated real-time colonoscopy quality feedback system strongly agreed with the endoscopists' quality assessments.Further study is required to validate this approach.
文摘ECG is an important tool for the primary diagnosis of heart diseases, which shows the electrophysiology of the heart. In our method, a single maternal abdominal ECG signal is taken as an input signal and the maternal P-QRS-T complexes of original signal is averaged and repeated and taken as a reference signal. LMS and RL5 adaptive filters algorithms are applied. The results showed that the fetal ECGs have been successfully detected. The accuracy of Daisy database was up to 84% of LM5 and 88% of RLS while PhysioNet was up to 98% and 96% for LMS and RLS respectively.