The principle and accuracy of 3-D coordinates acquisition using one single camera and the Aided Measuring Probe(AMP) are discussed in this paper. Using one single camera and one AMP which has several embedded targets ...The principle and accuracy of 3-D coordinates acquisition using one single camera and the Aided Measuring Probe(AMP) are discussed in this paper. Using one single camera and one AMP which has several embedded targets and one tip with known coordinates, the single camera′s orientation and location can be calculated. After orientation, the global coordinate system is obtained. During measurement, the camera is fixed firstly, then the AMP is held and the feature point is touched.The camera is triggered lastly. The position and orientation of the AMP are therefore calculated from the size and position of its image on the sensor. Since the tip point of AMP has known relation with the embedded targets, the feature point can be measured. Tests show that the accuracy of length measurement is 0.2 mm and accuracy for flatness measurement in XSY-plane is 0.1 mm.展开更多
In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers t...In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers the non-uniform distribution of blast loads on real column and the axial load-bending moment(P-M) interaction of CFST columns.Results of the SDOF analysis compare well with the experimental data reported in open literature and the values from finite element modeling(FEM) using the program LS-DYNA.Further comparisons between the results of SDOF and FEM analysis show that the proposed model is effective to predict the dynamic response of CFST columns with different blast conditions and column details.Also,it is found that the maximum responses of the columns are overestimated when ignoring the non-uniformity of blast loads,and that neglecting the effect of P-M interaction underestimates the maximum response of the columns with large axial load ratio against close range blast.The proposed SDOF model can be used in the design of the blast-loaded CFST columns.展开更多
In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors(RADFETs) in experimental. The possible t...In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors(RADFETs) in experimental. The possible traps and defects induced by ions implantation in the gate-oxide and their further impacting on the sensitivity and dose range of RADFETs were analyzed qualitatively. Our devices had the dry/wet/dry sandwich gate-oxide of 420 nm thick. Different ion-implanting doses and post-annealing temperatures were carried out during the RADFETs fabrication. We built a real time auto-measurement system to realize the auto-state-switch between irradiation and read-out modes, and in-situ measurement of output voltage for ten devices in turn at once of radiation experiment. The threshold voltage, dose range and sensitivity of RADFETs were extracted and analyzed in detail. The results showed that the highest sensitivity of 229 mV/Gy achieved when the implant dose was2.2×1011 cm.2 and the post-annealing temperature was 1000°C, and the dose range of 34 Gy as well.展开更多
文摘The principle and accuracy of 3-D coordinates acquisition using one single camera and the Aided Measuring Probe(AMP) are discussed in this paper. Using one single camera and one AMP which has several embedded targets and one tip with known coordinates, the single camera′s orientation and location can be calculated. After orientation, the global coordinate system is obtained. During measurement, the camera is fixed firstly, then the AMP is held and the feature point is touched.The camera is triggered lastly. The position and orientation of the AMP are therefore calculated from the size and position of its image on the sensor. Since the tip point of AMP has known relation with the embedded targets, the feature point can be measured. Tests show that the accuracy of length measurement is 0.2 mm and accuracy for flatness measurement in XSY-plane is 0.1 mm.
基金Project(KJZH14220)supported by the Achievement Transfer Program of Institutions of Higher Education in Chongqing,China
文摘In order to study the dynamic response of concrete-filled steel tube(CFST) columns against blast loads,a simplified model is established utilizing the equivalent single-degree-of-freedom(SDOF) method,which considers the non-uniform distribution of blast loads on real column and the axial load-bending moment(P-M) interaction of CFST columns.Results of the SDOF analysis compare well with the experimental data reported in open literature and the values from finite element modeling(FEM) using the program LS-DYNA.Further comparisons between the results of SDOF and FEM analysis show that the proposed model is effective to predict the dynamic response of CFST columns with different blast conditions and column details.Also,it is found that the maximum responses of the columns are overestimated when ignoring the non-uniformity of blast loads,and that neglecting the effect of P-M interaction underestimates the maximum response of the columns with large axial load ratio against close range blast.The proposed SDOF model can be used in the design of the blast-loaded CFST columns.
基金supported by the National Basic Research Program of China(Grant No.2015CB352100)
文摘In this work, we studied on the boron-ions implantation, including the implant dose and post-annealing temperature on the performance of PMOS radiation field-effect transistors(RADFETs) in experimental. The possible traps and defects induced by ions implantation in the gate-oxide and their further impacting on the sensitivity and dose range of RADFETs were analyzed qualitatively. Our devices had the dry/wet/dry sandwich gate-oxide of 420 nm thick. Different ion-implanting doses and post-annealing temperatures were carried out during the RADFETs fabrication. We built a real time auto-measurement system to realize the auto-state-switch between irradiation and read-out modes, and in-situ measurement of output voltage for ten devices in turn at once of radiation experiment. The threshold voltage, dose range and sensitivity of RADFETs were extracted and analyzed in detail. The results showed that the highest sensitivity of 229 mV/Gy achieved when the implant dose was2.2×1011 cm.2 and the post-annealing temperature was 1000°C, and the dose range of 34 Gy as well.