Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and t...Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.展开更多
Deduced the relationship between the power factor (PF) and the angular fre-quency according to the simplified equivalent circuit of asynchronous motor, forming a power factor auto-control system. An anti-interference ...Deduced the relationship between the power factor (PF) and the angular fre-quency according to the simplified equivalent circuit of asynchronous motor, forming a power factor auto-control system. An anti-interference circuit was also introduced in the middle voltage link of inverter to avoid the shift of the optimum PF point caused by the change of the load and the reliable run of the control system was assured. The experi-ment results show that it has a good self-adaptation in the whole scope of speed ad-justment and an obvious economization on energy while it runs under load.展开更多
Centrifugal pumps are being widely used in many industrial and commercial applications.Many of these pumps are being operated at constant speed but could provide energy savings through adjustable speed operations.The ...Centrifugal pumps are being widely used in many industrial and commercial applications.Many of these pumps are being operated at constant speed but could provide energy savings through adjustable speed operations.The purpose of this study was to get the energy saving rates of the multistage centrifugal pump with variable speed conditions.For this investigation an experimental set up of variable flow and pressure system was made to get energy saving rates and numerical analyses are applied to validate the pump performance.The energy saving and therefore the cost saving depends on the specific duty cycle of which the machine operates.Duty cycle is the proportion of time during which a component,device and system is operated.The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time.The system was operated at 50%or less of the pump capacity.The input power of the system was carried out by pump characteristics curve of each operating point.The energy consumption was done by the product of specific duty cycle and the input power of the system for constant speed and variable speed drive operation.The total energy consumed for constant speed drive pump was 75,770 k W.hr and for variable speed drive pump was 31,700 k W.hr.The total energy saving of the system was 44,070 k W.hr or 58.16%annually.So,this paper suggests a method of implementing an energy saving on variable-flow and pressure system of the multistage centrifugal pump.展开更多
基金Project(50838009) supported by the National Science Key Foundation 1 tem
文摘Aiming to give some advices on the ground coupled heat pump system design in Siehuan Province, China, a typical ground source heat pump (GSHP) system in Sichuan Province was tested in a whole operational year, and the parameters of temperature and flow rate in different parts of system were measured during this period. The seasonal energy efficiency ratio was calculated and the performance of heat pump system in summer was compared with that in winter. The result shows that the coefficient of performance of the system reaches 3.63 in summer and 3.49 in winter, respectively. The heat balance in underground rock mass is acquired basically throughout the year, and the heat accumulation in the earth tends to be zero.
基金Supported by Liaoning Educational Foundation(202183386)
文摘Deduced the relationship between the power factor (PF) and the angular fre-quency according to the simplified equivalent circuit of asynchronous motor, forming a power factor auto-control system. An anti-interference circuit was also introduced in the middle voltage link of inverter to avoid the shift of the optimum PF point caused by the change of the load and the reliable run of the control system was assured. The experi-ment results show that it has a good self-adaptation in the whole scope of speed ad-justment and an obvious economization on energy while it runs under load.
基金supported by the Korea government through the Korea institute of Energy Technology Evaluation and Planning(KETEP)The grant number is 20132010101870 for the Promotion of Science
文摘Centrifugal pumps are being widely used in many industrial and commercial applications.Many of these pumps are being operated at constant speed but could provide energy savings through adjustable speed operations.The purpose of this study was to get the energy saving rates of the multistage centrifugal pump with variable speed conditions.For this investigation an experimental set up of variable flow and pressure system was made to get energy saving rates and numerical analyses are applied to validate the pump performance.The energy saving and therefore the cost saving depends on the specific duty cycle of which the machine operates.Duty cycle is the proportion of time during which a component,device and system is operated.The duty cycle segmented into different flow rates and weighting the average value for each segment by the interval time.The system was operated at 50%or less of the pump capacity.The input power of the system was carried out by pump characteristics curve of each operating point.The energy consumption was done by the product of specific duty cycle and the input power of the system for constant speed and variable speed drive operation.The total energy consumed for constant speed drive pump was 75,770 k W.hr and for variable speed drive pump was 31,700 k W.hr.The total energy saving of the system was 44,070 k W.hr or 58.16%annually.So,this paper suggests a method of implementing an energy saving on variable-flow and pressure system of the multistage centrifugal pump.