Pyrene was chemically assembled on a glass plate surface in a monolayer manner via spacers con-taining triethylenetetramine (TETA) subunits. It has been demonstrated that the fluorescence emission of the film is sensi...Pyrene was chemically assembled on a glass plate surface in a monolayer manner via spacers con-taining triethylenetetramine (TETA) subunits. It has been demonstrated that the fluorescence emission of the film is sensitive to the presence of trace amount of nitroaromatic compound (NAC) vapors. As discovered in the present work, the response selectivity of the pyrene-functionalized film depends on the length of the spacer, the vapor pressure of a given NAC, and the quencher size. The film shows faster response to those quenchers which have higher vapor pressure and smaller size. Compared to the film with shorter spacers, the present film with longer flexible spacers shows a slower response to the NACs, but higher selectivity to the quencher size. Additionally, the detection limits to common ex-plosives in vapor phase, 2,4,6-trinitrotoluene (TNT) and 2,4-dinitrotoluene (DNT), are 7.14×10-12 and 5.49×10-11 g·mL-1, respectively. Further examinations indicated that the sensing process is fully re-versible, and the vapors of those common interference such as benzene, toluene, ethanol, and perfume have little effect upon the sensing performances of the film.展开更多
基金the National Natural Science Foundation of China (Grant No. 20674048)the Ministry of Education of China (Grant Nos. 03148 and 306015)+1 种基金"863" Program from Ministry of ScienceTechnology of China (Grant No. 2007AA032349)
文摘Pyrene was chemically assembled on a glass plate surface in a monolayer manner via spacers con-taining triethylenetetramine (TETA) subunits. It has been demonstrated that the fluorescence emission of the film is sensitive to the presence of trace amount of nitroaromatic compound (NAC) vapors. As discovered in the present work, the response selectivity of the pyrene-functionalized film depends on the length of the spacer, the vapor pressure of a given NAC, and the quencher size. The film shows faster response to those quenchers which have higher vapor pressure and smaller size. Compared to the film with shorter spacers, the present film with longer flexible spacers shows a slower response to the NACs, but higher selectivity to the quencher size. Additionally, the detection limits to common ex-plosives in vapor phase, 2,4,6-trinitrotoluene (TNT) and 2,4-dinitrotoluene (DNT), are 7.14×10-12 and 5.49×10-11 g·mL-1, respectively. Further examinations indicated that the sensing process is fully re-versible, and the vapors of those common interference such as benzene, toluene, ethanol, and perfume have little effect upon the sensing performances of the film.