期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
蒸压加气混凝土砌块新标准的实施对生产企业的影响 被引量:1
1
作者 姚伟 叶惠定 +3 位作者 庄红斌 刘永华 华如希 陆德新 《砖瓦》 2008年第3期61-62,共2页
阐述了GB11968-2006《蒸压加气混凝土砌块》与原标准GB/T11968-1997《蒸压加气混凝土砌块》在砌块等级、尺寸允许偏差、干密度级别等方面的变化,并分析了新标准的实施对生产企业的影响。
关键词 蒸压加气混凝土砌 标准 影响
下载PDF
Experimental Study on Improving Seismic Behavior of Load-Bearing Masonry Wall Made of Autoclaved Aerated Concrete 被引量:1
2
作者 于敬海 曹建锋 费添慧 《Transactions of Tianjin University》 EI CAS 2013年第6期419-424,共6页
To investigate the seismic behavior of autoclaved aerated concrete load-bearing masonry wall(AACLMW), a piece of control block wall without constructional measures and five pieces of block walls with different constru... To investigate the seismic behavior of autoclaved aerated concrete load-bearing masonry wall(AACLMW), a piece of control block wall without constructional measures and five pieces of block walls with different constructional measures were tested under low reversed cyclic loading which imitated low to moderate earthquake force. The seismic behavior of AACLMW with different constructional measures in terms of failure mode, hysteretic curve, deformation capacity and displacement ductility was studied and compared with that without constructional measures. The experimental results indicate that the constructional measures comprising constructional columns and horizontal concrete strips are effective for improving the seismic behavior of AACLMW. The study in this paper can provide a reliable experimental basis for further analysis and engineering application of AACLMW in the future. 展开更多
关键词 autoclaved aerated concrete(AAC) load-bearing masonry wall(LMW) seismic behavior constructional column concrete strip
下载PDF
Comparison Research of Bed Joints Construction and Bed Joints Reinforcement on Shear Parameters of AAC Masonry Walls
3
作者 Radoslaw Jasinski Lukasz Drobiec 《Journal of Civil Engineering and Architecture》 2016年第12期1329-1343,共15页
The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2... The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2) and on polyurethane glue and also walls without mortar (dry masonry). The wall compression strength (on mortar M5 class) (per EN 1052-1:2000) amounted tofc,mv= 2.97 N/mm2 (fk = 2.48 N/mm2), elastic modulus was Ecru = 2,040 N/mm2. Various structure of bed joints and head joints were applied and the following were used as reinforcement: steel trusses of EFZ 140/Z 140 type (Z1 type) and meshes made of plastics (Z2 type). Based on the tests carried out with regard to unreinforced elements, it was shown that the filling in of head joints with mortar had an advantageous effect on the values of cracking and destruction stresses. While, with the use of reinforcement, advantageous increase of stress was obtained only when the mortar was laid twice on both bed surfaces of masonry units. The application of reinforcement in the bed joints when the mortar was laid only on one bed joints surface of the masonry units reduced the values of cracking and destruction stresses in relation to the values obtained in the unreinforced walls. 展开更多
关键词 AAC thin layer mortar joints masonry shear strength reinforced shear walls.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部